Installation Guide
Page 1
Installation Guide AHA-1540CP/1542CP ISA-to-SCSI Plug and Play High-Performance Bus Master Host Adapter with SCSISelect Utility R
Installation Guide AHA-1540CP/1542CP ISA-to-SCSI Plug and Play High-Performance Bus Master Host Adapter with SCSISelect Utility R
Installation Guide
Page 2
1 Introduction This Installation Guide explains how to install and configure Adaptec AHATM-1540CP/1542CP Plug and Play ISA-to these devices. AHA-1540CP/1542CP host adapters are ready to install it in Plug and Play support. Before handling the host adapter, always ground yourself by installing ... adapters are also fully functional in Plug and Play or non-Plug and Play PCs. See the AHA-1540CP/1542CP User's Guide for more detailed information on your PC system includes SCSI disk drives or other devices that your PC. This Installation Guide assumes that support SCAM, you are fully ...
1 Introduction This Installation Guide explains how to install and configure Adaptec AHATM-1540CP/1542CP Plug and Play ISA-to these devices. AHA-1540CP/1542CP host adapters are ready to install it in Plug and Play support. Before handling the host adapter, always ground yourself by installing ... adapters are also fully functional in Plug and Play or non-Plug and Play PCs. See the AHA-1540CP/1542CP User's Guide for more detailed information on your PC system includes SCSI disk drives or other devices that your PC. This Installation Guide assumes that support SCAM, you are fully ...
Installation Guide
Page 3
The following table describes each component: J1 J2 J3 J4 S1 Label Description J1 External LED Connector J2 Floppy Drive Connector1 J3 Internal SCSI Connector 1 AHA-1542CP only. Host Adapter Layout This diagram shows the major AHA-1540CP/ 1542CP components. Label Description J4 External SCSI Connector S1 Switch Block 2
The following table describes each component: J1 J2 J3 J4 S1 Label Description J1 External LED Connector J2 Floppy Drive Connector1 J3 Internal SCSI Connector 1 AHA-1542CP only. Host Adapter Layout This diagram shows the major AHA-1540CP/ 1542CP components. Label Description J4 External SCSI Connector S1 Switch Block 2
Installation Guide
Page 4
... Plug and Play Functions I/O Port Address1 Enabled 330h-333h Floppy Controller (AHA-1542CP only) Host Adapter BIOS Address1 2 Enabled Enabled/ DC000h Global Settings from SCSISelect: Enable Sync Negotiation Yes Enable Fast SCSI Yes Enable Disconnection Yes Send Start Unit Command2 No Include in most... PCs. See Host Adapter Switches on page 11, and Configuring the SCSI Bus on Enabled "Plug and Play" SCAM Support ...
... Plug and Play Functions I/O Port Address1 Enabled 330h-333h Floppy Controller (AHA-1542CP only) Host Adapter BIOS Address1 2 Enabled Enabled/ DC000h Global Settings from SCSISelect: Enable Sync Negotiation Yes Enable Fast SCSI Yes Enable Disconnection Yes Send Start Unit Command2 No Include in most... PCs. See Host Adapter Switches on page 11, and Configuring the SCSI Bus on Enabled "Plug and Play" SCAM Support ...
Installation Guide
Page 5
Disable the AHA-1542CP floppy controller if you do this. (See Host Adapter Switches on the bottom of the host adapter with the slot and carefully insert it . 5 Align the bus ...
Disable the AHA-1542CP floppy controller if you do this. (See Host Adapter Switches on the bottom of the host adapter with the slot and carefully insert it . 5 Align the bus ...
Installation Guide
Page 6
...with the expansion slot cover screw. 6 Attach the host adapter bracket to the PC chassis with your AHA-1540CP/1542CP host adapter. Do not connect differential SCSI devices to determine whether a SCSI device is marked with enough connectors for all devices. 1 Enable termination on one edge of the ... PC chassis cover or reconnect the power yet. 3 Connecting SCSI Devices This section explains how to do this. 2 Plug the 50-pin female connector on the internal SCSI device that will be at the end of the ribbon cable. Caution: AHA-1540CP/1542CP host adapters support only single-ended...
...with the expansion slot cover screw. 6 Attach the host adapter bracket to the PC chassis with your AHA-1540CP/1542CP host adapter. Do not connect differential SCSI devices to determine whether a SCSI device is marked with enough connectors for all devices. 1 Enable termination on one edge of the ... PC chassis cover or reconnect the power yet. 3 Connecting SCSI Devices This section explains how to do this. 2 Plug the 50-pin female connector on the internal SCSI device that will be at the end of the ribbon cable. Caution: AHA-1540CP/1542CP host adapters support only single-ended...
Installation Guide
Page 8
... the 34-pin floppy ribbon cable (farthest from the twist in the cable) to assign SCSI IDs that are already in use the floppy controller on page 8) and set SCSI IDs manually for details. 7 Use the 34-pin floppy ribbon cable already in the cable designates drive A. Maintain pin-1 ...Adapter Switches on page 11. 1 Attach the connector on the PC's motherboard or disk controller. If you need to set to SCSI ID 7 by default and should not be changed. 4 Connecting Floppy Drives (AHA-1542CP) Follow these steps to connect floppy drives mounted inside the PC chassis to the first ...
... the 34-pin floppy ribbon cable (farthest from the twist in the cable) to assign SCSI IDs that are already in use the floppy controller on page 8) and set SCSI IDs manually for details. 7 Use the 34-pin floppy ribbon cable already in the cable designates drive A. Maintain pin-1 ...Adapter Switches on page 11. 1 Attach the connector on the PC's motherboard or disk controller. If you need to set to SCSI ID 7 by default and should not be changed. 4 Connecting Floppy Drives (AHA-1542CP) Follow these steps to connect floppy drives mounted inside the PC chassis to the first ...
Installation Guide
Page 9
... Press Esc to return to make selections. The host adapter finds devices on page 12 of SCSISelect (cpconfig.exe) is available on the Adaptec BBS. In a Plug and Play system you had to optimize performance or use the formatting or diagnostic utilities. The BBS phone number is...these steps to save the changes. 8 Running the SCSISelect Utility If the AHA-1540CP/1542CP onboard BIOS is enabled with switches, you change switch settings on the monitor. Press F6 to SCAM devices. 6 Configuring the SCSI Bus Your host adapter includes the SCSISelect utility, which lets you can ...
... Press Esc to return to make selections. The host adapter finds devices on page 12 of SCSISelect (cpconfig.exe) is available on the Adaptec BBS. In a Plug and Play system you had to optimize performance or use the formatting or diagnostic utilities. The BBS phone number is...these steps to save the changes. 8 Running the SCSISelect Utility If the AHA-1540CP/1542CP onboard BIOS is enabled with switches, you change switch settings on the monitor. Press F6 to SCAM devices. 6 Configuring the SCSI Bus Your host adapter includes the SCSISelect utility, which lets you can ...
Installation Guide
Page 10
...Adaptec SCSI low-level format utility. Not all PC systems are fully ISA compatible and properly support Bus Master DMA transferswhich are configuring. Configure/View Host Adapter Settings The Configuration screen displays these options unless you to reassign them. If you have multiple AHA-1540CP/1542CP ...If the test fails, try changing the DMA transfer rate to modify the remaining advanced options as listed on the SCSI bus: Enable Synchronous Negotiation, Enable Fast SCSI, Enable Disconnection, Send Start Unit Command, and Include in BIOS Scan. Highlight an option and press Enter to view...
...Adaptec SCSI low-level format utility. Not all PC systems are fully ISA compatible and properly support Bus Master DMA transferswhich are configuring. Configure/View Host Adapter Settings The Configuration screen displays these options unless you to reassign them. If you have multiple AHA-1540CP/1542CP ...If the test fails, try changing the DMA transfer rate to modify the remaining advanced options as listed on the SCSI bus: Enable Synchronous Negotiation, Enable Fast SCSI, Enable Disconnection, Send Start Unit Command, and Include in BIOS Scan. Highlight an option and press Enter to view...
Installation Guide
Page 11
...AHA-1540CP/1542CP as a standard (non-Plug and Play) host adapter. 10 Adaptec EZ-SCSI™ has a number of 32-bit applications that enhance the usefulness of UNIX have embedded drivers to 5.0 s Install more than eight hard drives (seven per host adapter) in your PC with the AHA-1540CP/ 1542CP... more than two hard drives in your PC is running To order EZ-SCSI and other removable media while your PC with the AHA-1540CP/1542CP under Windows 95. DOS/Windows 3.x Adaptec EZ-SCSI automatically loads the additional software support for installing new hardware devices. however, ...
...AHA-1540CP/1542CP as a standard (non-Plug and Play) host adapter. 10 Adaptec EZ-SCSI™ has a number of 32-bit applications that enhance the usefulness of UNIX have embedded drivers to 5.0 s Install more than eight hard drives (seven per host adapter) in your PC with the AHA-1540CP/ 1542CP... more than two hard drives in your PC is running To order EZ-SCSI and other removable media while your PC with the AHA-1540CP/1542CP under Windows 95. DOS/Windows 3.x Adaptec EZ-SCSI automatically loads the additional software support for installing new hardware devices. however, ...
Installation Guide
Page 14
...is powered • If necessary, the user should be registered in residential installations. All other trademarks are designed to radio communications. Adaptec, Inc. 691 South Milpitas Blvd. which the receiver is subject to the following measures: • Reorient or relocate the receiving ... FCC rules. Milpitas, CA 95035 Copyright © 1994, 1995 Adaptec, Inc. The full text of the associated label follows: This device complies with part 15 of Adaptec, Inc. Adaptec, the Adaptec logo, AHA, EZ-SCSI, and SCSISelect are trademarks of the FCC rules. FCC Compliance Statement...
...is powered • If necessary, the user should be registered in residential installations. All other trademarks are designed to radio communications. Adaptec, Inc. 691 South Milpitas Blvd. which the receiver is subject to the following measures: • Reorient or relocate the receiving ... FCC rules. Milpitas, CA 95035 Copyright © 1994, 1995 Adaptec, Inc. The full text of the associated label follows: This device complies with part 15 of Adaptec, Inc. Adaptec, the Adaptec logo, AHA, EZ-SCSI, and SCSISelect are trademarks of the FCC rules. FCC Compliance Statement...