User Manual
Page 1
...-45, 10/100 Mbps auto-negotiating ports on switched 10Mbps connections Baseline 10/100 Switch 10Mbps link 100Mbps link 1 Each port also supports automatic MDI/MDI-X detection. The Baseline 10/100 Switch comes with: One power cord for office use unmanaged switch. SuperStack® 3 Baseline 10/100 Switch 16-Port (3C16470) and 24-Port (3C16471) User Guide DUA1647...
...-45, 10/100 Mbps auto-negotiating ports on switched 10Mbps connections Baseline 10/100 Switch 10Mbps link 100Mbps link 1 Each port also supports automatic MDI/MDI-X detection. The Baseline 10/100 Switch comes with: One power cord for office use unmanaged switch. SuperStack® 3 Baseline 10/100 Switch 16-Port (3C16470) and 24-Port (3C16471) User Guide DUA1647...
User Manual
Page 2
...tzte Buchsen dürfen an diese Datensteckdosen angeschlossen werden. 10BASE-T/100BASE-TX Ports The Baseline 10/100 Switch has 16 (3C16470) or 24 (3C16471) 10/100 Mbps auto-negotiating ports. If a packet has been then the Switch will read the priority level and determine whether the packet should be used as ... tagged frames. A 24-port unit is configured to comply with the relevant sections of the cable to an RJ-45 port on the Baseline 10/100 Switch, and the other end to the appropriate RJ-45 port on a different queue from lower priority traffic, and is given preference over another...
...tzte Buchsen dürfen an diese Datensteckdosen angeschlossen werden. 10BASE-T/100BASE-TX Ports The Baseline 10/100 Switch has 16 (3C16470) or 24 (3C16471) 10/100 Mbps auto-negotiating ports. If a packet has been then the Switch will read the priority level and determine whether the packet should be used as ... tagged frames. A 24-port unit is configured to comply with the relevant sections of the cable to an RJ-45 port on the Baseline 10/100 Switch, and the other end to the appropriate RJ-45 port on a different queue from lower priority traffic, and is given preference over another...
User Manual
Page 5
... following step 6). When mounting the unit, you . 2 Locate a mounting bracket over the mounting holes on disabling the broadcast operation. Rack Mounting the Units The Baseline 10/100 Switch is installed and configured correctly. CAUTION: Disconnect all cables. PROBLEM SOLVING Refer to the information about LEDs given earlier in . All ports appear to... Power Inlet AC Line Frequency Input Voltage Current Rating Maximum Power Consumption Maximum Power Dissipation IEC 320 50/60 Hz 100-240 VAC 1 Amps (maximum) 3C16470: 15 VA 3C16471: 20 VA 3C16470: 52 BTU/hr 3C16471: 68 BTU/hr 5
... following step 6). When mounting the unit, you . 2 Locate a mounting bracket over the mounting holes on disabling the broadcast operation. Rack Mounting the Units The Baseline 10/100 Switch is installed and configured correctly. CAUTION: Disconnect all cables. PROBLEM SOLVING Refer to the information about LEDs given earlier in . All ports appear to... Power Inlet AC Line Frequency Input Voltage Current Rating Maximum Power Consumption Maximum Power Dissipation IEC 320 50/60 Hz 100-240 VAC 1 Amps (maximum) 3C16470: 15 VA 3C16471: 20 VA 3C16470: 52 BTU/hr 3C16471: 68 BTU/hr 5