Question posted by typerrin054 on July 22nd, 2010

Unit Doesnt Turn On.

The unit doesnt turn on. It has been working great. I live in a hot humid place, and have to drain the water tank on the unit  on a regular basis. Normally if the tank is full the a/c unit it wont run. I tried draining the tank, and also cleaning each filer in the front. I've tried the test/reset switch on the units power cord, and that isnt the problem either. Can you help me? Thanks Tyler [email protected]

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp CV10NH Manual Pages

CV-10NH Operation Manual - Page 3

...; INCLUDED E-7 • PART NAMES E-8 • INSTALL WINDOW PANEL E-10 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-14 • PRE-OPERATION...UNIT OPERATION E-25 • DRAINAGE E-26 • MAINTENANCE E-27 • BEFORE CALLING FOR SERVICE E-28 E-1 ENGLISH ENGLISH This manual explains the proper use of your new air conditioner. This manual should be kept in a safe place...
CV-10NH Operation Manual - Page 5

..., call Sharp Toll Free at no event shall Sharp be liable or in the United States. Contact your Sharp Authorized Servicer to you. TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT... or defects in addition to whatever implied warranties may not apply to Obtain Service: CV-10NH Portable Air Conditioner. ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED...
CV-10NH Operation Manual - Page 6

...cord can result in damage to the unit and possibly fire. • Always use wire, pins or other objects in place of a proper fuse. • ...air conditioner. Use of the unit. • Ensure the power supply used has an appropriate voltage rating. WARNING FOR POWER SUPPLY CORD • This air conditioner uses a plug with the proper amp rating. E-4 a burning smell), turn it in water...
CV-10NH Operation Manual - Page 7

...air conditioner. (See Page 26) If any water remains in the tank, it may be plugged into the room. • Do not block the exhaust air outlet with a cord that is fully grounded. Drained water may cause water...• Improper use , especially if using gas appliances. • Be sure to turn the unit off and disconnect the power supply cord before perform- The plug must have no kinks ...
CV-10NH Operation Manual - Page 8

... will rise. When water tank inside the unit may cause the unit to shut off for the compressor to keep out direct sunlight while in low ambient temperature conditions, especially at a slower speed. In this is normal and does not indicate a problem with the unit. • This air conditioner blows the warm air generated by your air conditioner work harder and less...
CV-10NH Operation Manual - Page 9

... and vibration. Do not attempt to roll the unit over objects. • The unit must be placed on a firm foundation to be rolled on carpet surfaces. MIN.12" (30cm) INCLUDED MIN.12" (30cm) SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1. ENGLISH LOCATION • The air conditioner should only be cut down in size because the...
CV-10NH Operation Manual - Page 10

... signal receiver 4 window 5 5 POWER Button 6 6 OPERATION Lamp (red) 7 7 TIMER Lamp (orange) 8 9 8 MEGA COOL Lamp (green) 9 9 Air inlet 9 REAR VIEW 0 0 Exhaust air outlet q q Window exhaust adapter w w Exhaust hose e e Remote control hook r t r Air filters y t Drainage nozzle and stopcock y Power supply cord hooks u Drainpipe nozzle and stopcock u i Power supply...
CV-10NH Operation Manual - Page 16

... hose and insert it into the two holes on the unit, and firmly attach them to the unit. Unacceptable Acceptable Acceptable E-14 Make sure they are securely attached...window. Insert the two projections on the exhaust hose adapter into the window exhaust adapter, and turn it (approx. MODE EXHAUST HOSE COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container Install DEHUMIDIFICATION ...
CV-10NH Operation Manual - Page 18

... batteries are the same type. • If the remote control does not operate normally after replacing the batteries, press the RESET button using the unit for service. You will not be performed. PRE-OPERATION CHECKS POWER PLUG CHECK This air conditioner uses a fused power plug. The circuit breaker is activated, power is supplied, and...
CV-10NH Operation Manual - Page 20

... 64°F to 86°F. 1 4 4 Press the FAN button to select COOL mode. AUTO QUIET LOW HIGH TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is securely inserted into the lower...
CV-10NH Operation Manual - Page 21

..., the water tank inside the unit may be changed. 1 TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will turn the drainage...Turn the drainage nozzle to the OPEN position. 3 Pull the stopcock out from the drainage nozzle. • Always perform this mode, the air conditioner dehumidifies the room. In this case, drain out the water within the unit...
CV-10NH Operation Manual - Page 22

... the MODE button to select VENT mode. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. QUIET LOW HIGH 3 TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will turn the drainage nozzle to set the desired fan speed. • Although the louvers...
CV-10NH Operation Manual - Page 23

...horizontal louvers manually. • Manual adjustment of the horizontal louvers can cause the unit to malfunction when the remote control is used for adjustment. • When the... of time. E-21 ENGLISH TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION 1 Press the LOUVERS button on the louvers. Horizontal louvers LEFT / RIGHT AIR FLOW DIRECTION Hold the vertical louver as shown...
CV-10NH Operation Manual - Page 24

... TIMER button again during operation. TO CANCEL Press the CANCEL button. 1 • The orange TIMER lamp on the unit will light. • The unit will turn off . MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set the temperature or fan speed during cooling mode. • The remote control will display...
CV-10NH Operation Manual - Page 25

... the ON TIMER, the temperature will turn off. Hold the button down to ... down to turn on 6.5 hours later. ENGLISH TIMER OPERATION ON TIMER The unit will turn on automatically ...unit will show the re- E-23 TO CANCEL TIMER Press the CANCEL button. • The orange TIMER lamp on the unit.... 1 Press the ON TIMER button. • The time setting will change the setting, the unit...
CV-10NH Operation Manual - Page 26

... display the next time you set , the TIMER setting will be memorized and will appear on the unit will turn off automatically according to a maximum of 12 hours. NOTES ON TIMER SETTING AND OPERATION • The...the OFF TIMER or ON TIMER activated, the ON TIMER or OFF TIMER setting will be set from 10 to show the re- E-24 Display shown when you set the OFF TIMER or ON TIMER. &#...
CV-10NH Operation Manual - Page 27

... set at its last settings. • If the unit has been unplugged since it was last operated, it will turn off. • Upon starting MAIN UNIT operation, the drainage pump inside the unit runs for about a minute, which may produce an audible gurgling sound. ENGLISH MAIN UNIT OPERATION Use this mode when the remote control...
CV-10NH Operation Manual - Page 28

... minute. 8 Remove the hose from the drainage nozzle, and replace the stopcock. • Keep the hose band and drain grommet in case of water that the water tank inside the unit is removed, a small amount of re-used . 5 Turn the drainage nozzle to the CLOSE position. 6 Remove the stopcock from spilling). Maximum amount of re-used...
CV-10NH Operation Manual - Page 29

... gently push the filter back into place. Doing so may be reduced or stop completely if the insect guard net becomes clogged with dust, the airflow will be cleaned every two weeks. Insect guard net MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Perform drainage to drain out water within the unit. (See Page 26 "When the...
CV-10NH Operation Manual - Page 30

... water tank inside the unit. • This air conditioner evaporates water condensed during operation. Clean and replace the filters. • Is the cooling coil frozen? No air will not be heard when the unit is perfectly normal. • A soft, swishing noise can be twisted or bent. This is sound of the compressor starting AUXILIARY mode. TIMER DOES NOT WORK...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV10NH - 10,000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.