Dell PowerConnect 6248 Support Question
Find answers below for this question about Dell PowerConnect 6248.Need a Dell PowerConnect 6248 manual? We have 5 online manuals for this item!
Question posted by lecolslic on October 15th, 2013
How Setup Lag 6248
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell PowerConnect 6248 Manual Pages
User's Guide - Page 19
..., read the release notes for RJ-45 or SFP interfaces. 1
Introduction
This section describes the switch user-configurable features.
The Dell PowerConnect 6248 supports 48 1000Base-T copper ports and 4 "combo" ports for this section include: • System Features • Switching Features • Routing Features • IPv6 • Quality of service, security, and system management...
User's Guide - Page 25
... hubs and switches ...switch supports auto-detection between two switches that share a point-to-point link segment, and to automatically configure both switches to prevent buffer overflows. The PowerConnect...LAG Configuration." Media-Dependent Interface (MDI) is known as Media-Dependent Interface with higher speed switches by traffic competing for ports or LAGs, see "Port Configuration" or "LAG...
User's Guide - Page 59
..., 6248, and 6224F Rear Panel
Dual 10G slots for XFP, CX4, or stacking modules
Dual 10G slots for XFP, CX4, or 10Gbase-T modules. Figure 4-6. The right slot (Bay 2) can support a plug-in Dual 10GbE XFP module, a 10GBase-T module, or a CX4 module. Rear Panel
Each PowerConnect 6200 series switch provides an RS-232 maintenance...
User's Guide - Page 62
... of the short stacking cables into either of the stacking ports of the devices are connected.
4. For PoE switches, you can also attach a redundant DC power supply, such as the PowerConnect RPS-600. The PowerConnect 6248 has four fans.
You can verify operation by observing the LEDs. You can verify operation by connecting adjacent...
User's Guide - Page 82
... until you return to configure security access for SNMPv3 (for the Easy Setup Wizard.
82
Configuring Dell PowerConnect If there is activated. • Sets up the SNMP community string to be powered on in the field without a serial connection, the switch waits 60 seconds for you to respond to a set-up prompt if...
User's Guide - Page 386
... in the CLI Reference Guide: • LACP Commands The following table summarizes the equivalent CLI commands for Multiple Ports 1.
LAG Membership
Your switch supports 48 LAGs per system, and eight ports per LAG. LACP Commands
CLI Command lacp port-priority lacp system-priority lacp timeout show lacp ethernet show lacp port-channel
Description Configures...
User's Guide - Page 396
... Multicast Forward
Use the Bridge Multicast Forward page to enable attaching ports or LAGs to a switch that is enabled, multicast packets are :
- Once IGMP Snooping is attached to be affected.
• Forwarding Mode - Selects the VLAN to a neighboring Multicast switch. Specifies the multicast forwarding mode for the selected VLAN. Figure 7-76. Bridge Multicast...
Getting Started Guide - Page 14
... specified will use the default values). After the initial configuration, you received it. • The PowerConnect switch booted successfully. • The console connection was established and the Dell Easy Setup Wizard prompt appears on the screen
of the switch, obtain the following information from the already-connected console port or remotely through the console...
Getting Started Guide - Page 266
... counters show stack-port diag show switch
show supported switchtype
LED
LED Dell Power Connect PC6248P ,PC6224P ,PC6248 , PC6224ו.PC6224F -
PowerConnect 6200
PC 6224
1-1
PC 6248
2-1
...
Release Notes - Page 3
... or upgrading of firmware be thoroughly reviewed prior to this product. System Firmware Version 3.2.0.6
Page 1 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Introduction
This document provides specific information for the Dell PowerConnect 6200 Series switches, firmware version 3.2.0.6.
It is recommended that the same version of this procedure may result in the...
Release Notes - Page 4
.... Hardware Supported
PowerConnect 6224 PowerConnect 6248 PowerConnect 6224F PowerConnect 6224P PowerConnect 6248P
2
System...PowerConnect™ 6200 Series Systems CLI Reference Guide and the Dell™ PowerConnect™ 6200 Series Configuration Guide.
NOTE: OMNM 4.1 will not discover the switches running firmware version 2.x or earlier.
Users should upgrade to a PowerConnect...
Release Notes - Page 5
... unit. System Firmware Version 3.2.0.6
Page 3 When the management unit fails, only the management switch needs to be downloaded via the CLI or GUI and supports 1500 characters.
¾ VLAN...of CX-4/Stacking Modules
This feature will function according to its module ID. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Added Functionality in this Release ¾ Non-Stop Forwarding
This...
Release Notes - Page 7
...to share information between neighboring devices (routers, bridges, access servers, and switches). Industry Standard Discovery Protocol (ISDP) is a proprietary Layer 2 network protocol...The feature prevents a class of man-in a VLAN). PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
¾ MLD Snooping (RFC2710)
In IPv4, Layer 2 switches can use IGMP Snooping to limit the flooding of multicast...
Release Notes - Page 15
... automatically enabled. If your previous configuration had flow control disabled, you upgrade a switch to support long usernames.
¾ Flow Control
Flow Control is now a common command for configuring all trap flags. System Firmware Version 3.2.0.6
Page 13 PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
¾ Trap Configuration
In previous versions of the software...
Release Notes - Page 19
...obsoleted in RFC
Set the unitMgrCfgFile -> dataChanged flag in CLI to be deleted for logging syslog. The switch must be rebooted for syslog description in the respective APIs. Added validation for the cutthrough configuration to accept...MAC address 33:33:00:00:00:16.
PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Issues Resolved
The following is a list of updated time with...
Release Notes - Page 21
... case before processing. Corrected the display of the MAC Address in order to the switch. Corrected the error handling for interface ?j?????? (639). Increased the maximum length to authenticate...VLAN shows incorrect VLAN ID. Switch gives error message when entered upper case letter for the interface name. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Description Cannot enter...
Release Notes - Page 25
...-port / {ethernet | stack}
Description This command is used to the Dell™ PowerConnect™ 6200 Series Systems CLI Reference Guide for 90 seconds. Default: From the factory...in the quiet state for details.
PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
RADIUS Accounting Servers
Title radius-server host acct
Description The switches do not support creating accounting server...
Release Notes - Page 27
...router down and other sessions.
VLAN configuration is applied correctly.
Banner MOTD: The switches Console and Web sessions are inaccessible until the user enters a response or the... then the MOTD acknowledgement ends the connection and resumes processing of a LAG. None. PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Known Issues
Summary Non-configuration file getting read an ...
Release Notes - Page 29
PowerConnect 6224/6224F/6224P/6248/6248P Release Notes
Summary
ISDP updates are not including Voice VLAN Reply TLV...Firmware Version 3.2.0.6
Page 27
If enable authorization is changed .
Cannot change its VLAN properties.
The user may change LAG mode from Static to Dynamic via CLI. User Impact
Upon changing configuration immediately after the configuration is set to enter ...
Release Notes - Page 31
... 6224/6224F/6224P/6248/6248P Release Notes
LACP
Description LAGs Supported
VLAN
Description vlan association mac command limitations
User Impact Number of LAGs supported:
• Up to 18 Dynamic LAGs • 48 Static LAGs Limitations (stack of the PowerConnect 6200 series switches. User Impact Ensure the correct command is for VLAN routing interfaces.
User Impact This behavior...
Similar Questions
How To Configure Switches Powerconnect To Route Multicast Traffic
(Posted by baxmim 9 years ago)
How To Show Mac Address Switch Powerconnect
(Posted by soundlmgale 9 years ago)
How To Setup Seperate Vlan On Dell Powerconnect 6248
(Posted by Redfranni 10 years ago)
How To Setup Two Vlan On Dell Powerconnect 3500 Series
(Posted by Richamp 10 years ago)