Warranty Information
Page 1
... States or Canada and applies only when the major appliance is not installed in accordance with published installation instructions. 11. Consumable parts are excluded from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, installation not in accordance with...limited warranty. Repairs when your major appliance is used in a manner that have been removed, altered or cannot be provided by Whirlpool. 5. WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Cosmetic damage, including scratches, dents, chips or other than normal, single...
... States or Canada and applies only when the major appliance is not installed in accordance with published installation instructions. 11. Consumable parts are excluded from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, installation not in accordance with...limited warranty. Repairs when your major appliance is used in a manner that have been removed, altered or cannot be provided by Whirlpool. 5. WHIRLPOOL SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Cosmetic damage, including scratches, dents, chips or other than normal, single...
Installation Guide
Page 2
... killed or seriously injured if you what the potential hazard is the safety alert symbol. TABLE OF CONTENTS VENT SYSTEM SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Electrical Requirements 7 Venting Requirements 7 INSTALLATION INSTRUCTIONS 8 Venting Methods 8 Install Vent System 9 Rear Mounting - Blower Motor 11 Complete Installation 12 Make Electrical Connections 13...
... killed or seriously injured if you what the potential hazard is the safety alert symbol. TABLE OF CONTENTS VENT SYSTEM SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Electrical Requirements 7 Venting Requirements 7 INSTALLATION INSTRUCTIONS 8 Venting Methods 8 Install Vent System 9 Rear Mounting - Blower Motor 11 Complete Installation 12 Make Electrical Connections 13...
Installation Guide
Page 4
...Needed ■ Jigsaw or keyhole saw ■ Drill 3 mm) drill bit for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is required. IMPORTANT: Observe all governing codes and ordinances. ■ Have a qualified technician install the downdraft... vent. Cabinet Construction: Downdraft vent is the installer's responsibility to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for pilot holes ■ Pencil ■ Tape measure or ruler ■ Flat-blade screwdriver ■ ...
...Needed ■ Jigsaw or keyhole saw ■ Drill 3 mm) drill bit for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is required. IMPORTANT: Observe all governing codes and ordinances. ■ Have a qualified technician install the downdraft... vent. Cabinet Construction: Downdraft vent is the installer's responsibility to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for pilot holes ■ Pencil ■ Tape measure or ruler ■ Flat-blade screwdriver ■ ...
Installation Guide
Page 7
... ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all joints in the Maximum Length of solid copper wire to aluminum. D = Measurement... of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all governing codes and ordinances. The specified CFM varies from : National Fire Protection Association 1 ...
... ■ Wire sizes must conform with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all joints in the Maximum Length of solid copper wire to aluminum. D = Measurement... of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all governing codes and ordinances. The specified CFM varies from : National Fire Protection Association 1 ...
Installation Guide
Page 9
... 6" (15.2 cm) to the vent box. wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m) Transition = 4.5 ft (1.4 cm) Length of 35 ft (8.9 m). 2 - 90° elbow = 10.0 ft (3 m) 1 - Remove parts packages, downdraft vent and blower box from the downdraft vent and blower box. 4. Install the right and left undercounter mounting brackets to 3¹⁄₄...
... 6" (15.2 cm) to the vent box. wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m) Transition = 4.5 ft (1.4 cm) Length of 35 ft (8.9 m). 2 - 90° elbow = 10.0 ft (3 m) 1 - Remove parts packages, downdraft vent and blower box from the downdraft vent and blower box. 4. Install the right and left undercounter mounting brackets to 3¹⁄₄...
Installation Guide
Page 13
... the power supply cable through the conduit connector and into place. Check Operation 1. B A C Electrical Shock Hazard Electrically ground blower. Connect ground wire to seal all parts and panels before servicing. If the blower does not operate: ■ Check that rear of cooktop overlaps edge of the downdraft vent for matching your...
... the power supply cable through the conduit connector and into place. Check Operation 1. B A C Electrical Shock Hazard Electrically ground blower. Connect ground wire to seal all parts and panels before servicing. If the blower does not operate: ■ Check that rear of cooktop overlaps edge of the downdraft vent for matching your...
Installation Guide
Page 16
...) one-piece top trim Order Part Number W10387678 (black) Order Part Number W10388421 (white) For model series UXD8636DY 36" (91.4 cm) one-piece top trim Order Part Number W10387679 (black) Order Part Number W10388422 (white) 16 In the U.S.A. Our consultants provide assistance with any questions or concerns at : Customer eXperience Centre Whirlpool Canada LP 200 - 6750...
...) one-piece top trim Order Part Number W10387678 (black) Order Part Number W10388421 (white) For model series UXD8636DY 36" (91.4 cm) one-piece top trim Order Part Number W10387679 (black) Order Part Number W10388422 (white) 16 In the U.S.A. Our consultants provide assistance with any questions or concerns at : Customer eXperience Centre Whirlpool Canada LP 200 - 6750...
Installation Guide
Page 17
... or use or when it was purchased. The removal and reinstallation of your sales slip together for product service if your authorized Whirlpool dealer to correct house wiring or plumbing. 2. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR ...PROVIDED HEREIN. Service must provide proof of purchase or installation date for Factory Specified Parts and repair labor to or furnished with original model/serial numbers that is used for repairs. WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase...
... or use or when it was purchased. The removal and reinstallation of your sales slip together for product service if your authorized Whirlpool dealer to correct house wiring or plumbing. 2. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR ...PROVIDED HEREIN. Service must provide proof of purchase or installation date for Factory Specified Parts and repair labor to or furnished with original model/serial numbers that is used for repairs. WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY LIMITED WARRANTY For one year from the date of purchase...
Dimension Guide
Page 1
... vent. NOTES: Locate power supply junction box at either side of 3 Because Whirlpool Corporation policy includes a continuous commitment to your specific installation. q Use dimensions for...Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is required... (91.4 cm) Retractable (Pop-Up) Downdraft Vent System PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS UXD8630DY UXD8636DY Electrical A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is not applicable...
... vent. NOTES: Locate power supply junction box at either side of 3 Because Whirlpool Corporation policy includes a continuous commitment to your specific installation. q Use dimensions for...Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is required... (91.4 cm) Retractable (Pop-Up) Downdraft Vent System PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS UXD8630DY UXD8636DY Electrical A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is not applicable...
Dimension Guide
Page 2
...) metal vent. q Do not use 4" (10.2 cm) laundry-type wall caps. Flexible elbows count twice as much as part of rigid metal vent. The damper should be mounted for right, left, or rear venting if needed for your HVAC professional for... vent. Instructions packed with product. D = Measurement of 3 Ref. Front (Standard) Mounted Blower Motor B A D M C E F G L H K J I Because Whirlpool Corporation policy includes a continuous commitment to locale. Vent system can be installed to change materials and specifications without notice. q The length of vent system and...
...) metal vent. q Do not use 4" (10.2 cm) laundry-type wall caps. Flexible elbows count twice as much as part of rigid metal vent. The damper should be mounted for right, left, or rear venting if needed for your HVAC professional for... vent. Instructions packed with product. D = Measurement of 3 Ref. Front (Standard) Mounted Blower Motor B A D M C E F G L H K J I Because Whirlpool Corporation policy includes a continuous commitment to locale. Vent system can be installed to change materials and specifications without notice. q The length of vent system and...