Operating Instructions
Page 13
Using the Radio Data System (RDS) (Models of area code CEL, CEK only) Displaying RDS information Notes t t t t Notes Receiving RDS broadcasts Note 13GB
Using the Radio Data System (RDS) (Models of area code CEL, CEK only) Displaying RDS information Notes t t t t Notes Receiving RDS broadcasts Note 13GB
Service Manual
Page 1
Continued on next page - FM STEREO/FM-AM RECEIVER 9-877-864-06 2007E04-1 © 2007. 05 Sony Corporation Home Audio Division Published by Sony Techno Create Corporation 1 Photo: Black type SPECIFICATIONS Outputs (Analog) MD/TAPE (OUT), VIDEO 1 (AUDIO OUT) Voltage: 500 mV Impedance: 10 kilohms Bass ...70 dB 0.3% 0.5% 45 dB at 1 kHz 30 Hz - 15 kHz, +0.5/-2 dB 60 dB at 400 kHz - SERVICE MANUAL Ver. 1.5 2007. 05 STR-DE197 US Model Canadian Model AEP Model AUDIO POWER SPECIFICATIONS POWER OUTPUT AND TOTAL HARMONIC DISTORTION: (Models of ar ea code AEP Power Output a t Ster eo...
Continued on next page - FM STEREO/FM-AM RECEIVER 9-877-864-06 2007E04-1 © 2007. 05 Sony Corporation Home Audio Division Published by Sony Techno Create Corporation 1 Photo: Black type SPECIFICATIONS Outputs (Analog) MD/TAPE (OUT), VIDEO 1 (AUDIO OUT) Voltage: 500 mV Impedance: 10 kilohms Bass ...70 dB 0.3% 0.5% 45 dB at 1 kHz 30 Hz - 15 kHz, +0.5/-2 dB 60 dB at 400 kHz - SERVICE MANUAL Ver. 1.5 2007. 05 STR-DE197 US Model Canadian Model AEP Model AUDIO POWER SPECIFICATIONS POWER OUTPUT AND TOTAL HARMONIC DISTORTION: (Models of ar ea code AEP Power Output a t Ster eo...
Service Manual
Page 2
... be erased when you change the AM tuning scale to check AC leakage. LEAKAGE TEST The AC leakage from any AM station, turn off the receiver. Follow the manufacturers' instructions to 10 kHz (or 9 kHz), repeat the procedure. The "limit" indication is 0.75 V, so analog meters must not ... SH-63Trd are suitable. (See Fig. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY. 2 ATTENTION AU COMPOSANT AYANT RAPPORT À LA SÉCURITÉ!! STR-DE197 AM tuner section Tuning range Models of area code US, CND ...
... be erased when you change the AM tuning scale to check AC leakage. LEAKAGE TEST The AC leakage from any AM station, turn off the receiver. Follow the manufacturers' instructions to 10 kHz (or 9 kHz), repeat the procedure. The "limit" indication is 0.75 V, so analog meters must not ... SH-63Trd are suitable. (See Fig. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY. 2 ATTENTION AU COMPOSANT AYANT RAPPORT À LA SÉCURITÉ!! STR-DE197 AM tuner section Tuning range Models of area code US, CND ...
Service Manual
Page 10
...at the same time, then each segment turns on one after another. The FL tube will be selected for a moment and the receiver starts scanning. Press any button other than the function buttons to turn on . Procedure: 1. Software Version Display Mode The software version...light on 1 half light on the main power. 2. Procedure: 1. The destination and the software version are scrolled for the AM tuning interval. STR-DE197 SECTION 3 TEST MODE Fluorescent Indicator Tube Test Mode All fluorescent segments are pressed. • Operation of RDS station. ING/CHAR +] button, ...
...at the same time, then each segment turns on one after another. The FL tube will be selected for a moment and the receiver starts scanning. Press any button other than the function buttons to turn on . Procedure: 1. Software Version Display Mode The software version...light on 1 half light on the main power. 2. Procedure: 1. The destination and the software version are scrolled for the AM tuning interval. STR-DE197 SECTION 3 TEST MODE Fluorescent Indicator Tube Test Mode All fluorescent segments are pressed. • Operation of RDS station. ING/CHAR +] button, ...
Service Manual
Page 11
... +5V - Ground 49 SIRCS I Sircs signal input from remote control receiver IC. 50 TUNER MUTE O Muting control signal output to AD1 I Function keys signal input 29 AVDD - A/D converter power supply pin (+5 V) 30 AV.REF - Analog ground 21 VERSION I Destination select signal input (Fixed ...signal output 11 IC PIN DESCRIPTION • IC201 µPD78045FGF-134-3B9 (SYSTEM CONTROLLER, FL DISPLAY DRIVER) Pin No. SECTION 4 DIAGRAMS STR-DE197 4-1. Pin Name I/O Pin Description 1 to 7 DIG7 to DIG1 O Digit drive signal output to sound control IC. 15 RDS DATA ...
... +5V - Ground 49 SIRCS I Sircs signal input from remote control receiver IC. 50 TUNER MUTE O Muting control signal output to AD1 I Function keys signal input 29 AVDD - A/D converter power supply pin (+5 V) 30 AV.REF - Analog ground 21 VERSION I Destination select signal input (Fixed ...signal output 11 IC PIN DESCRIPTION • IC201 µPD78045FGF-134-3B9 (SYSTEM CONTROLLER, FL DISPLAY DRIVER) Pin No. SECTION 4 DIAGRAMS STR-DE197 4-1. Pin Name I/O Pin Description 1 to 7 DIG7 to DIG1 O Digit drive signal output to sound control IC. 15 RDS DATA ...
Service Manual
Page 15
... 9L SOUND CONTROL IC401 REC L 32 CD L 7 VOL L 29 MD L 5 VIDEO 2 3 TREBLE L MIDDLE L BASS L OUT L 20 VIDEO 1 1 CONTROL 15 14 CLK DATA CLK DATA STB STR-DE197 AUDIO AMP IC403 3 1 ELECTRONIC VOLUME IC402 L 3 IN L OUT 2 VOLUME CONTROL 8 9 10 VIDEO 1,MD/TAPE SELECT IC404 1 2 4 3 13 5 Q474 INV. Q424 INV. 4-3. J801 (2/2) -3 L... TUNER MUTE CE DO DI CL VOL A VOL B X1 X2 SIRCS 38 39 13 RV201 MASTER VOLUME 34 35 49 71 X201 4.19MHz 1 REMOTE CONTROL RECEIVER IC202 -24V 77 - 72,70 - 62 7 - 1,80 - 78 FL201 VACUUM FLUORESCENT DISPLAY F1 F2 VLOAD S 1 I S15 DIG1 I DIG10 AD1...
... 9L SOUND CONTROL IC401 REC L 32 CD L 7 VOL L 29 MD L 5 VIDEO 2 3 TREBLE L MIDDLE L BASS L OUT L 20 VIDEO 1 1 CONTROL 15 14 CLK DATA CLK DATA STB STR-DE197 AUDIO AMP IC403 3 1 ELECTRONIC VOLUME IC402 L 3 IN L OUT 2 VOLUME CONTROL 8 9 10 VIDEO 1,MD/TAPE SELECT IC404 1 2 4 3 13 5 Q474 INV. Q424 INV. 4-3. J801 (2/2) -3 L... TUNER MUTE CE DO DI CL VOL A VOL B X1 X2 SIRCS 38 39 13 RV201 MASTER VOLUME 34 35 49 71 X201 4.19MHz 1 REMOTE CONTROL RECEIVER IC202 -24V 77 - 72,70 - 62 7 - 1,80 - 78 FL201 VACUUM FLUORESCENT DISPLAY F1 F2 VLOAD S 1 I S15 DIG1 I DIG10 AD1...