XE-A507 Operation Manual in English
Page 5
... Daily net report...43 9 Prior to Programming...44 Programming Keyboard Layout...44 How to Program Alphanumeric Characters 45 Mobile phone method...45 Entering character codes...46 10 Programming...47 Basic Instructions...47 Programming screen...47 Programming example...48 DEPT/PLU Programming...50 Department...51 PLU/UPC...52 PLU range...53 Functional Programming...54 -
... Daily net report...43 9 Prior to Programming...44 Programming Keyboard Layout...44 How to Program Alphanumeric Characters 45 Mobile phone method...45 Entering character codes...46 10 Programming...47 Basic Instructions...47 Programming screen...47 Programming example...48 DEPT/PLU Programming...50 Department...51 PLU/UPC...52 PLU range...53 Functional Programming...54 -
XE-A507 Operation Manual in English
Page 19
... and should be programmed. PLUs are entered, only the sales quantity is pre-programmed to "PRESET" for entry type and zero (0) for each PLU code. * A total of 7000 codes, including UPC codes, can be previously programmed. (Refer to the section "PLU/UPC" of 7000* PLUs/sub-departments. ...Procedure When using a programmed unit price PLU code (1 to 99999) p Unit price * A (max. 8...
... and should be programmed. PLUs are entered, only the sales quantity is pre-programmed to "PRESET" for entry type and zero (0) for each PLU code. * A total of 7000 codes, including UPC codes, can be previously programmed. (Refer to the section "PLU/UPC" of 7000* PLUs/sub-departments. ...Procedure When using a programmed unit price PLU code (1 to 99999) p Unit price * A (max. 8...
XE-A507 Operation Manual in English
Page 20
Procedure Scan UPC code UPC code (max. 19 digits) p * After an UPC entry, you may be entered are UPC-A, UPC-E, EAN-8, EAN-13 and ITF-14. In this function for entering a sale of UPC code, please refer to "11 Universal Product Code (UPC) or European Article Number (EAN)". For details of two or more the same items. d p You can enter the barcodes using scanner or...
Procedure Scan UPC code UPC code (max. 19 digits) p * After an UPC entry, you may be entered are UPC-A, UPC-E, EAN-8, EAN-13 and ITF-14. In this function for entering a sale of UPC code, please refer to "11 Universal Product Code (UPC) or European Article Number (EAN)". For details of two or more the same items. d p You can enter the barcodes using scanner or...
XE-A507 Operation Manual in English
Page 21
...sound. In this feature when you need to enter two or more the same items. This feature helps you when you sell a large quantity of items or need to enter quantities that contain decimals. entry (direct) Dept. code PLU code PLU code UPC code d p p p* Unit price Unit price... A A Dept. ■■ Multiplication entries Use this case, enter the unit price and press the A key, enter the department code and press the A key (UPC learning function). ...
...sound. In this feature when you need to enter two or more the same items. This feature helps you when you sell a large quantity of items or need to enter quantities that contain decimals. entry (direct) Dept. code PLU code PLU code UPC code d p p p* Unit price Unit price... A A Dept. ■■ Multiplication entries Use this case, enter the unit price and press the A key, enter the department code and press the A key (UPC learning function). ...
XE-A507 Operation Manual in English
Page 22
Procedure When you use this case, enter the unit price and press the A key, enter the department code and press the A key (UPC learning function). • Selling quantity: Up to four-digit integer + three-digit decimal • Base quantity: Up to two digits (integer...Selling q'ty Base q'ty Unit price per base q'ty Department key Dept.code PLU code PLU code UPC code d p p p* Unit price Unit price Scan UPC code * A A * After an UPC entry, you may be requested to enter a unit price with the display "UNDEFINED CODE" and beep sound. In this function when your customer wants to purchase...
Procedure When you use this case, enter the unit price and press the A key, enter the department code and press the A key (UPC learning function). • Selling quantity: Up to four-digit integer + three-digit decimal • Base quantity: Up to two digits (integer...Selling q'ty Base q'ty Unit price per base q'ty Department key Dept.code PLU code PLU code UPC code d p p p* Unit price Unit price Scan UPC code * A A * After an UPC entry, you may be requested to enter a unit price with the display "UNDEFINED CODE" and beep sound. In this function when your customer wants to purchase...
XE-A507 Operation Manual in English
Page 24
... displayed. Key operation 5099887654302 p 750 A 5 A A Print 22 Dept. Undefined UPC code p Unit price a To cancel the operation A Dept. The code, associated department and unit price entered are required to enter its associated department is applied. • You can use the key. selection Department ... the repeat entry, use the UPC learning function in the UPC file and used for the UPC code, the text of unknown UPCs) When you enter or scan an undefined UPC code, you are stored in the training mode. ■■ UPC learning function (creation and registration ...
... displayed. Key operation 5099887654302 p 750 A 5 A A Print 22 Dept. Undefined UPC code p Unit price a To cancel the operation A Dept. The code, associated department and unit price entered are required to enter its associated department is applied. • You can use the key. selection Department ... the repeat entry, use the UPC learning function in the UPC file and used for the UPC code, the text of unknown UPCs) When you enter or scan an undefined UPC code, you are stored in the training mode. ■■ UPC learning function (creation and registration ...
XE-A507 Operation Manual in English
Page 30
... amount of f the refund, then press the key and the corresponding department key in this order; if an item entered f p into a PLU/UPC is returned, enter the corresponding PLU/UPC code, then press the and keys f and if a refund item is the same as the one of a subtotal depending on the programming. Discount for a ...entries f d p For a refund entry, press the key just before you press a department key, key, or key or f just before pressing the key is the one entered into an UPC, press the key and scan the UPC code. ■■ Discount entries Your register allows you scan an...
... amount of f the refund, then press the key and the corresponding department key in this order; if an item entered f p into a PLU/UPC is returned, enter the corresponding PLU/UPC code, then press the and keys f and if a refund item is the same as the one of a subtotal depending on the programming. Discount for a ...entries f d p For a refund entry, press the key just before you press a department key, key, or key or f just before pressing the key is the one entered into an UPC, press the key and scan the UPC code. ■■ Discount entries Your register allows you scan an...
XE-A507 Operation Manual in English
Page 36
Example (Indirect void by key sequence operation You can void department, PLU/subdepartment, UPC and item refund. For the refund indirect void, press the key after you to enter the quantity to void only for the integer quantity. t Display 49 @ 5 t p A NOTE The register allows you press ... the item to void by cursor operation You can void department, PLU/subdepartment, UPC, item refund, amount discount/premium and percent entries. before pressing the key), you find an incorrect entry before you scan t f an UPC code. t d p Press the key just before you press a department key, ...
Example (Indirect void by key sequence operation You can void department, PLU/subdepartment, UPC and item refund. For the refund indirect void, press the key after you to enter the quantity to void only for the integer quantity. t Display 49 @ 5 t p A NOTE The register allows you press ... the item to void by cursor operation You can void department, PLU/subdepartment, UPC, item refund, amount discount/premium and percent entries. before pressing the key), you find an incorrect entry before you scan t f an UPC code. t d p Press the key just before you press a department key, ...
XE-A507 Operation Manual in English
Page 41
...BY RANGE BY DEPT ALL CLERK IND. Also the UPC codes are printed in the sequence of PLUs and UPCs. CLERK HOURLY DAILY NET Description General report Operating modes OP X/Z X1/Z1 X2/Z2 X1, Z1 X2, Z2 Data to be entered Department by group report Individual department group report Department...Total-in-drawer report X1 X2 X1 X2 PLU/UPC sales report by specified range PLU/UPC report by associated department X1, Z1 X1, Z1 X2, Z2 PLU/UPC code (The range can be specified by entering start and end codes.) X2, Z2 Department code All clerk report Individual clerk report Hourly report (all...
...BY RANGE BY DEPT ALL CLERK IND. Also the UPC codes are printed in the sequence of PLUs and UPCs. CLERK HOURLY DAILY NET Description General report Operating modes OP X/Z X1/Z1 X2/Z2 X1, Z1 X2, Z2 Data to be entered Department by group report Individual department group report Department...Total-in-drawer report X1 X2 X1 X2 PLU/UPC sales report by specified range PLU/UPC report by associated department X1, Z1 X1, Z1 X2, Z2 PLU/UPC code (The range can be specified by entering start and end codes.) X2, Z2 Department code All clerk report Individual clerk report Hourly report (all...
XE-A507 Operation Manual in English
Page 54
...: PLUnnnnn for (PLUs)) • TYPE (Use the selective entry) Type of each PLU/UPC for commission for clerks. Up to be assigned to "PRESET". • DEPT. Procedure Select a pertinent PLU code, or directly enter a PLU code or UPC code. (The UPC code can be entered by barcode scanning.) Program each item as follows: • PRICE (Use the numeric entry...
...: PLUnnnnn for (PLUs)) • TYPE (Use the selective entry) Type of each PLU/UPC for commission for clerks. Up to be assigned to "PRESET". • DEPT. Procedure Select a pertinent PLU code, or directly enter a PLU code or UPC code. (The UPC code can be entered by barcode scanning.) Program each item as follows: • PRICE (Use the numeric entry...
XE-A507 Operation Manual in English
Page 99
... 3 NCD (or HRI) format 4 (Free code) UPC-E • UPC-E is a zero-suppressed version of UPC-A that conforms to the programming section "UPC Function" in the source marking) For entry, you must be entered. Maker code Nation code In case of 13 digits number. Item code ITF-14 Maker code P.I Nation code Item code 97 Maker code Nation code Item code EAN-13 • Ordinary EAN...
... 3 NCD (or HRI) format 4 (Free code) UPC-E • UPC-E is a zero-suppressed version of UPC-A that conforms to the programming section "UPC Function" in the source marking) For entry, you must be entered. Maker code Nation code In case of 13 digits number. Item code ITF-14 Maker code P.I Nation code Item code 97 Maker code Nation code Item code EAN-13 • Ordinary EAN...
XE-A507 Operation Manual in English
Page 100
... not read automatically the encoded price of digits enterable for sales entries are as shown below: Code entry UPC-A UPC-A w/leading zero UPC-A w/o check digit UPC-E EAN-8 EAN-13 No add-on code 12 13 11 6 8 13 2-digit add-on code 5-digit add-on code. Therefore, the total number of the press code and does not store the 2-digit and...
... not read automatically the encoded price of digits enterable for sales entries are as shown below: Code entry UPC-A UPC-A w/leading zero UPC-A w/o check digit UPC-E EAN-8 EAN-13 No add-on code 12 13 11 6 8 13 2-digit add-on code 5-digit add-on code. Therefore, the total number of the press code and does not store the 2-digit and...
XE-A507 Operation Manual in English
Page 109
...the power, and consult a Sharp Authorized Servicer. Checking • Is power supplied to the electric outlet? • Is the power cord plug out or loosely connected to the electric outlet? • Is the register in screen-save mode? • Is a clerk code assigned to the register? ...roll, and press the key. The correct numeric data must be entered. STACK OVER UNDEFINED CODE UPC CODE IS NOT EXISTING Turn off the power, and repair the printer. TEND ONLY COMM. The correct code data must be entered. Perform the correct key operation. The open price entry) PRINTER ...
...the power, and consult a Sharp Authorized Servicer. Checking • Is power supplied to the electric outlet? • Is the power cord plug out or loosely connected to the electric outlet? • Is the register in screen-save mode? • Is a clerk code assigned to the register? ...roll, and press the key. The correct numeric data must be entered. STACK OVER UNDEFINED CODE UPC CODE IS NOT EXISTING Turn off the power, and repair the printer. TEND ONLY COMM. The correct code data must be entered. Perform the correct key operation. The open price entry) PRINTER ...