LC-40LE810UN | LC-46LE810UN | LC-52LE810UN | LC-60LE810UN Operation Manual
Page 65
... HD images. • The HD cable/satellite set-top box may need to be displayed. • Is the ETHERNET cable connected correctly? Refer to external monitor. - When connecting a laptop PC to the TV, check that the program you forget the secret number, clear the secret number using the following : - ...Check that display output mode of the PC is set up HDMI connection or component connection. • If the program content is not of your secret number above, cut it...
... HD images. • The HD cable/satellite set-top box may need to be displayed. • Is the ETHERNET cable connected correctly? Refer to external monitor. - When connecting a laptop PC to the TV, check that the program you forget the secret number, clear the secret number using the following : - ...Check that display output mode of the PC is set up HDMI connection or component connection. • If the program content is not of your secret number above, cut it...
Service Manual
Page 38
... Version LCD Con Version HLNI 100 1.02/1.00 0900626000T0001 LED TCON Version EQ DATA CHECKSUM 16 ROM TEMPERATURE 7B LAMP ERROR 0 USA MONITOR ERR CAUSE 0 NORMAL STANDBY CAUSE ERROR STANDBY CAUSE 0 1) 0 0H 0M 4) 0 0H 0M 2) 0 0H 0M 5) 0 0H 0M 40_UNDER 3) 0 0H 0M (6) Adjustment process...key. 3) When the center icon LED blinks, release your finger from the outlet to enter the adjustment process mode. LC-40/46/52/60LE810UN (1st Edition) 3. Entering and exiting the adjustment process mode 1) Before entering the adjustment process mode, the AV position RESET in the adjustment process...
... Version LCD Con Version HLNI 100 1.02/1.00 0900626000T0001 LED TCON Version EQ DATA CHECKSUM 16 ROM TEMPERATURE 7B LAMP ERROR 0 USA MONITOR ERR CAUSE 0 NORMAL STANDBY CAUSE ERROR STANDBY CAUSE 0 1) 0 0H 0M 4) 0 0H 0M 2) 0 0H 0M 5) 0 0H 0M 40_UNDER 3) 0 0H 0M (6) Adjustment process...key. 3) When the center icon LED blinks, release your finger from the outlet to enter the adjustment process mode. LC-40/46/52/60LE810UN (1st Edition) 3. Entering and exiting the adjustment process mode 1) Before entering the adjustment process mode, the AV position RESET in the adjustment process...
Service Manual
Page 39
... 6 7 Item MAIN Version BOOT Version Monitor/Monitor BOOT Version LCD CON Version / LED CON Version Netflix ESN FRC-N Auto Script Version TCON Master/Slave Serial Version TOUCH SENSOR UCON VERSION TEMPERATURE LAMP ERROR MONITOR ERR CAUSE NORMAL STANDBY CAUSE ERROR STANDBY ...CAUSE INDUSTRY INIT INDUSTRY INIT(-Hotel) PUBLIC MODE...Monitor and monitor boot software version LCD controller software version Audio data checksum Panel temperature Number of adjustment process mode... mode Accumulated main operation time Reset Accumulated monitor operation...
... 6 7 Item MAIN Version BOOT Version Monitor/Monitor BOOT Version LCD CON Version / LED CON Version Netflix ESN FRC-N Auto Script Version TCON Master/Slave Serial Version TOUCH SENSOR UCON VERSION TEMPERATURE LAMP ERROR MONITOR ERR CAUSE NORMAL STANDBY CAUSE ERROR STANDBY ...CAUSE INDUSTRY INIT INDUSTRY INIT(-Hotel) PUBLIC MODE...Monitor and monitor boot software version LCD controller software version Audio data checksum Panel temperature Number of adjustment process mode... mode Accumulated main operation time Reset Accumulated monitor operation...
Service Manual
Page 41
... 1 2 3 4 5 6 7 8 1 2 3 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 Item CALC RESET VAL1 VAL2 VAL3 VAL4 VAL5 VAL6 MONITOR TIME OUT MONITOR MAX TEMP MONITOR ERROR CAUSE RESET LCD TEST PATTERN LCD TEST PATTERN1 LCD TEST PATTERN2 LCD TEST PATTERN3 LCD TEST PATTERN4 TV TEST PATTERN 1 TV TEST PATTERN 2 FRC-N ...SENSITIVITY CH UP KEY SENSITIVITY CH DOWN KEY SENSITIVITY VOL UP KEY SENSITIVITY VOL DOWN KEY SENSITIVITY KEY STRENGTH GET MODE POWER KEY STRENGTH MENU KEY STRENGTH INPUT KEY STRENGTH CH UP KEY STRENGTH CH DOWN KEY STRENGTH VOL UP ...
... 1 2 3 4 5 6 7 8 1 2 3 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 Item CALC RESET VAL1 VAL2 VAL3 VAL4 VAL5 VAL6 MONITOR TIME OUT MONITOR MAX TEMP MONITOR ERROR CAUSE RESET LCD TEST PATTERN LCD TEST PATTERN1 LCD TEST PATTERN2 LCD TEST PATTERN3 LCD TEST PATTERN4 TV TEST PATTERN 1 TV TEST PATTERN 2 FRC-N ...SENSITIVITY CH UP KEY SENSITIVITY CH DOWN KEY SENSITIVITY VOL UP KEY SENSITIVITY VOL DOWN KEY SENSITIVITY KEY STRENGTH GET MODE POWER KEY STRENGTH MENU KEY STRENGTH INPUT KEY STRENGTH CH UP KEY STRENGTH CH DOWN KEY STRENGTH VOL UP ...
Service Manual
Page 42
... detected 22 LCD controller Rom error in the cause of continuous "out of range", PC input mode in the cause of abnormal temperature in the cause of abnormal monitor mode in EEPROM whenever possible. LC-40/46/52/60LE810UN (1st Edition) Page 23 24 Line 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 Item ERROR STANDBY CAUSE1 ERROR STANDBY CAUSE2 ERROR STANDBY...
... detected 22 LCD controller Rom error in the cause of continuous "out of range", PC input mode in the cause of abnormal temperature in the cause of abnormal monitor mode in EEPROM whenever possible. LC-40/46/52/60LE810UN (1st Edition) Page 23 24 Line 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 Item ERROR STANDBY CAUSE1 ERROR STANDBY CAUSE2 ERROR STANDBY...
Service Manual
Page 43
... Before adjustment, check that the pattern for Sharp LCD US. Signal adjustment 8.1. Main microcomputer/monitor microcomputer software writing (Main PWB: QPWBXF452WJZZ) ...mode using the process adjustment remote control. 5 - 9 Press the Enter key to white) 8.2.2 Process mode Adjustment point Process mode Adjustment conditions Adjustment procedure Enter the process adjustment mode...backlight). [Adjustment position] 1/4 3/4 1/2 1/2 8.2. Microcomputer software writing LC-40/46/52/60LE810UN (1st Edition) 7.1. Make adjustment so that the flicker located in the...
... Before adjustment, check that the pattern for Sharp LCD US. Signal adjustment 8.1. Main microcomputer/monitor microcomputer software writing (Main PWB: QPWBXF452WJZZ) ...mode using the process adjustment remote control. 5 - 9 Press the Enter key to white) 8.2.2 Process mode Adjustment point Process mode Adjustment conditions Adjustment procedure Enter the process adjustment mode...backlight). [Adjustment position] 1/4 3/4 1/2 1/2 8.2. Microcomputer software writing LC-40/46/52/60LE810UN (1st Edition) 7.1. Make adjustment so that the flicker located in the...
Service Manual
Page 46
...the adjustment procedure, refer to "Kameyama Model Integrated Monitor WB Adjustment Specification V1.92".) Adjustment Adjustment conditions Adjustment...**** MG2B**** MG2R**** MG2Y**** Point 1 LEV10045 MG1G**** MG1B**** MG1R**** MG1Y**** Writing MSET0003 5 - 12 Process mode 1) Send the "adjustment process" code using the remote control. cution KRSW0001 2) Set the point 6 to ...jig. 2 Automatic [Command] [Adjustment procedure] adjustment exe- Then compare the R and G values; LC-40/46/52/60LE810UN (1st Edition) 9. Point 4 LEV40133 MG4G**** MG4B**** MG4R**** MG4Y**** 7) Set the point 1 ...
...the adjustment procedure, refer to "Kameyama Model Integrated Monitor WB Adjustment Specification V1.92".) Adjustment Adjustment conditions Adjustment...**** MG2B**** MG2R**** MG2Y**** Point 1 LEV10045 MG1G**** MG1B**** MG1R**** MG1Y**** Writing MSET0003 5 - 12 Process mode 1) Send the "adjustment process" code using the remote control. cution KRSW0001 2) Set the point 6 to ...jig. 2 Automatic [Command] [Adjustment procedure] adjustment exe- Then compare the R and G values; LC-40/46/52/60LE810UN (1st Edition) 9. Point 4 LEV40133 MG4G**** MG4B**** MG4R**** MG4Y**** 7) Set the point 1 ...
Service Manual
Page 53
.... In this way, the AV positions, video and audio adjustment settings are displayed with caution. • Usually, the headphones and monitor audio outputs can be changed .). None None • Press the volume UP/DOWN key, and the mute icon appears for menu ...RCD" (loop provided) OFF Function to feed the remote controller-received signal to "Variable". When "AV Mode" key is changed like "Dynamic (Fixed)". - 10)INPUT MODE FIXED LC-40/46/52/60LE810UN (1st Edition) Selection Default Explanation Limit in Setting Exception Remarks Selection between "Variable", "Fixed", "ACON ...
.... In this way, the AV positions, video and audio adjustment settings are displayed with caution. • Usually, the headphones and monitor audio outputs can be changed .). None None • Press the volume UP/DOWN key, and the mute icon appears for menu ...RCD" (loop provided) OFF Function to feed the remote controller-received signal to "Variable". When "AV Mode" key is changed like "Dynamic (Fixed)". - 10)INPUT MODE FIXED LC-40/46/52/60LE810UN (1st Edition) Selection Default Explanation Limit in Setting Exception Remarks Selection between "Variable", "Fixed", "ACON ...
Service Manual
Page 72
...Error description Initial communication from the main CPU 6 - 18 Monitor ERR STBY table Outline: Location: Communication/Power failure detected by the monitor microcomputer is not received. Display 02 03 04 05 06 ... error 8 Start-up time-out Time acquisition time-out Regular communication time-out Lamp failure Monitor temperature failure PS_ON (AC_DET) failure D_POW (DET_13V) failure D_POW (DET_D3V3) failure Panel power...out Preset start-up time-out during the beginning of the process mode A. Page 1 of the process mode A: MONITOR ERR CAUSE "0" if there is cleared to 0 on EEPROM, and ...
...Error description Initial communication from the main CPU 6 - 18 Monitor ERR STBY table Outline: Location: Communication/Power failure detected by the monitor microcomputer is not received. Display 02 03 04 05 06 ... error 8 Start-up time-out Time acquisition time-out Regular communication time-out Lamp failure Monitor temperature failure PS_ON (AC_DET) failure D_POW (DET_13V) failure D_POW (DET_D3V3) failure Panel power...out Preset start-up time-out during the beginning of the process mode A. Page 1 of the process mode A: MONITOR ERR CAUSE "0" if there is cleared to 0 on EEPROM, and ...