EN104 Installation Guide
Page 2
... Model EN104 hub), eight (on the Model EN108 hub), and sixteen (on the Model EN116 hub) vista 10BASE-T network ports (RJ-45) that refers to collectively as the Model EN104/EN108/EN116 hub. Each hub is listed individually when information is jabbering • Automatic polarity detection for small businesses, home offices, and lowdensity workgroups of the NETGEAR™ Model EN104, Model EN108, or Model...
... Model EN104 hub), eight (on the Model EN108 hub), and sixteen (on the Model EN116 hub) vista 10BASE-T network ports (RJ-45) that refers to collectively as the Model EN104/EN108/EN116 hub. Each hub is listed individually when information is jabbering • Automatic polarity detection for small businesses, home offices, and lowdensity workgroups of the NETGEAR™ Model EN104, Model EN108, or Model...
EN104 Installation Guide
Page 3
... Contents Model EN104 hub or Model EN108 hub 10 BASE-T HUB EN104 LINK Rx Pwr Col 10 BASE-T HUB EN108 Pwr Col 1 2 3 4 or Model EN116 hub LINK Rx 5 6 7 8 10 BASE-T HUB EN116 Pwr Col 1 2 3 4 5 6 7 8 1 2 3 4 LINK Rx 5 6 7 8 Mounting kit Power adapter Installation guide, Warranty & Owner Registration Card, Support Information Card 8731FA Verify that your package contains the following: • Model EN104 hub, Model EN108 hub, or Model EN116 hub...
... Contents Model EN104 hub or Model EN108 hub 10 BASE-T HUB EN104 LINK Rx Pwr Col 10 BASE-T HUB EN108 Pwr Col 1 2 3 4 or Model EN116 hub LINK Rx 5 6 7 8 10 BASE-T HUB EN116 Pwr Col 1 2 3 4 5 6 7 8 1 2 3 4 LINK Rx 5 6 7 8 Mounting kit Power adapter Installation guide, Warranty & Owner Registration Card, Support Information Card 8731FA Verify that your package contains the following: • Model EN104 hub, Model EN108 hub, or Model EN116 hub...
EN104 Installation Guide
Page 4
... button Front Panel of the Model EN108 hub 10 BASE-T HUB EN108 Pwr Col 1 2 3 4 LINK Rx 5 6 7 8 Front Panel of the Model EN116 hub 10 BASE-T HUB EN116 Pwr Col 1 2 3 4 5 6 7 8 1 2 3 4 LINK Rx 5 6 7 8 8732FA Vista 10BASE-T Network Ports with Built-in LEDs The front panel of the Model EN104 hub has four RJ-45 10BASE-T ports, the Model EN108 hub has eight RJ-45 10BASE...
... button Front Panel of the Model EN108 hub 10 BASE-T HUB EN108 Pwr Col 1 2 3 4 LINK Rx 5 6 7 8 Front Panel of the Model EN116 hub 10 BASE-T HUB EN116 Pwr Col 1 2 3 4 5 6 7 8 1 2 3 4 LINK Rx 5 6 7 8 8732FA Vista 10BASE-T Network Ports with Built-in LEDs The front panel of the Model EN104 hub has four RJ-45 10BASE-T ports, the Model EN108 hub has eight RJ-45 10BASE...
EN104 Installation Guide
Page 5
...supplied to a PC. This uplink configuration eliminates the need to select Normal (MDI-X) wiring for connection to a hub or a switch through port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on the top right corner of each vista 10BASE-T port) Active (for BNC) Rx (for BNC...) Active (for AUI) Rx (for connection to the hub. Normal/Uplink Push Button The Normal/Uplink push button allows ...
...supplied to a PC. This uplink configuration eliminates the need to select Normal (MDI-X) wiring for connection to a hub or a switch through port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on the top right corner of each vista 10BASE-T port) Active (for BNC) Rx (for BNC...) Active (for AUI) Rx (for connection to the hub. Normal/Uplink Push Button The Normal/Uplink push button allows ...
EN104 Installation Guide
Page 6
... -+ Rear Panel of the Model EN108 hub AUI Active Rx BNC Active Rx 12Vdc 1.2A -+ Rear Panel of the Model EN116 hub 8738FA Model EN104/EN108/EN116 Ethernet Hub Installation Guide The rear panel also includes a DC power receptacle. The rear panel of the Model EN108 hub and the Model EN116 hub also has an AUI port in... addition to a backbone network using thin coaxial cable. Rear Panel The rear panel of the hub has a BNC port that you can use to connect to a...
... -+ Rear Panel of the Model EN108 hub AUI Active Rx BNC Active Rx 12Vdc 1.2A -+ Rear Panel of the Model EN116 hub 8738FA Model EN104/EN108/EN116 Ethernet Hub Installation Guide The rear panel also includes a DC power receptacle. The rear panel of the Model EN108 hub and the Model EN116 hub also has an AUI port in... addition to a backbone network using thin coaxial cable. Rear Panel The rear panel of the hub has a BNC port that you can use to connect to a...
EN104 Installation Guide
Page 7
... Operating humidity Ventilation Operating conditions Service access Power Wiring hardware Requirement Ambient temperature between the mounting holes on the back of the hub and mark the wall to match the location of 90%, noncondensing. Minimum 12 inches (19.68 cm) front and back for...hub. Front and back clearance for ventilation. Minimum 2 inches (5.08 cm) on a flat least 2 inches of electromagnetic noise (such as punchdown blocks. Make sure your hub on all sides for cables and wiring hardware such as photocopy machine or arc welder). Model EN104/EN108/EN116 Ethernet Hub...
... Operating humidity Ventilation Operating conditions Service access Power Wiring hardware Requirement Ambient temperature between the mounting holes on the back of the hub and mark the wall to match the location of 90%, noncondensing. Minimum 12 inches (19.68 cm) front and back for...hub. Front and back clearance for ventilation. Minimum 2 inches (5.08 cm) on a flat least 2 inches of electromagnetic noise (such as punchdown blocks. Make sure your hub on all sides for cables and wiring hardware such as photocopy machine or arc welder). Model EN104/EN108/EN116 Ethernet Hub...
EN104 Installation Guide
Page 8
... interface to the RJ-45 ports on your hub by using port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on your PC or server and the hub to a PC, use a regular straightthrough UTP cable. Connect a PC to the Hub You can connect PCs, Apple Macintosh computers,... UNIX workstations, or any of the RJ-45 ports on the Model EN116 hub, set the Normal/Uplink push button to Normal. (The Model EN108 hub is shown in the illustration.) Pwr Col 1 2 3 4 5 6 ...
... interface to the RJ-45 ports on your hub by using port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on your PC or server and the hub to a PC, use a regular straightthrough UTP cable. Connect a PC to the Hub You can connect PCs, Apple Macintosh computers,... UNIX workstations, or any of the RJ-45 ports on the Model EN116 hub, set the Normal/Uplink push button to Normal. (The Model EN108 hub is shown in the illustration.) Pwr Col 1 2 3 4 5 6 ...
EN104 Installation Guide
Page 9
...type of users supported on the Hub Model EN104 hub: Ports 1-3 Ports 1-3 Model EN108 hub: Ports 1-7 Ports 1-7 Model EN116 hub: Ports 1-15 Ports 1-15 Connecting Device Cable Used PC, server, or router Hub or switch PC, server, or router Hub or switch PC, server, or router Hub or switch Straight-through cable Crossover ...through cable Crossover cable Set the Normal/Uplink Push Button If you are connecting to port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on the Model EN116 hub, are MDI-X (or Normal) ports. The 10BASE-T ports can be used to 100 meters (m) ...
...type of users supported on the Hub Model EN104 hub: Ports 1-3 Ports 1-3 Model EN108 hub: Ports 1-7 Ports 1-7 Model EN116 hub: Ports 1-15 Ports 1-15 Connecting Device Cable Used PC, server, or router Hub or switch PC, server, or router Hub or switch PC, server, or router Hub or switch Straight-through cable Crossover ...through cable Crossover cable Set the Normal/Uplink Push Button If you are connecting to port 4 on the Model EN104 hub, port 8 on the Model EN108 hub, or port 16 on the Model EN116 hub, are MDI-X (or Normal) ports. The 10BASE-T ports can be used to 100 meters (m) ...
EN104 Installation Guide
Page 10
... path goes from hub 4 to hub 2, to hub 1, to hub 3, and then to five, as shown in any communication path to hub 5. Model EN104 hub 10 BASE-T HUB EN104 Pwr LINK Rx Col Model EN108 hub Normal 10 BASE-T HUB EN108 Pwr Col 1 2 3 4 LINK Rx 5 6 7 8 Model EN116 hub Uplink 10 BASE-T HUB EN116 Pwr Col 1 2 3 4 5 6 7 8 1 2 3 4 LINK Rx 5 6 7 8 Uplink 8733FA Model EN104/EN108/EN116 Ethernet Hub Installation Guide When...
... path goes from hub 4 to hub 2, to hub 1, to hub 3, and then to five, as shown in any communication path to hub 5. Model EN104 hub 10 BASE-T HUB EN104 Pwr LINK Rx Col Model EN108 hub Normal 10 BASE-T HUB EN108 Pwr Col 1 2 3 4 LINK Rx 5 6 7 8 Model EN116 hub Uplink 10 BASE-T HUB EN116 Pwr Col 1 2 3 4 5 6 7 8 1 2 3 4 LINK Rx 5 6 7 8 Uplink 8733FA Model EN104/EN108/EN116 Ethernet Hub Installation Guide When...
EN104 Installation Guide
Page 11
.... connector BNC 50 terminator Model EN104 hub Model EN108 hub Model EN116 hub BNC 50 terminator 8736FA Note: Ethernet specifications limit a BNC segment to 30 BNC connections, specify a minimum of 1.64 feet (0.5 m) between the hubs in the coaxial cable between any two stations, and limit segments to hubs. You can connect other Model EN104/EN108/EN116 hubs, servers, workstations, or...
.... connector BNC 50 terminator Model EN104 hub Model EN108 hub Model EN116 hub BNC 50 terminator 8736FA Note: Ethernet specifications limit a BNC segment to 30 BNC connections, specify a minimum of 1.64 feet (0.5 m) between the hubs in the coaxial cable between any two stations, and limit segments to hubs. You can connect other Model EN104/EN108/EN116 hubs, servers, workstations, or...
EN104 Installation Guide
Page 12
... the AUI port must have the signal quality error (SQE) test function disabled. Thick coaxial cable Cable terminator device AUI cable 10BASE-5 transceiver Model EN108 hub and Model EN116 hubs 8737FA Note: Ethernet specifications limit thick coaxial segments to 100 stations and 1,640 feet (500 m) in length, and they specify... connecting a thick coaxial segment. Connect to a Network Using the AUI Port The AUI port on the rear panel (found only on the Model EN108 hub and the Model EN116 hub) is limited to 164 feet (50 m). Model EN104/EN108/EN116 Ethernet Hub Installation Guide
... the AUI port must have the signal quality error (SQE) test function disabled. Thick coaxial cable Cable terminator device AUI cable 10BASE-5 transceiver Model EN108 hub and Model EN116 hubs 8737FA Note: Ethernet specifications limit thick coaxial segments to 100 stations and 1,640 feet (500 m) in length, and they specify... connecting a thick coaxial segment. Connect to a Network Using the AUI Port The AUI port on the rear panel (found only on the Model EN108 hub and the Model EN116 hub) is limited to 164 feet (50 m). Model EN104/EN108/EN116 Ethernet Hub Installation Guide
EN104 Installation Guide
Page 13
When power has been applied to the power outlet on the wall. Verify Installation To complete the installation, connect the power cord first to the power receptacle on the hub rear panel and then to the hub: • The green Pwr (Power) LED on the front panel is on. • The green Link LED on each connected port is on. • The green Active LED on each connected AUI port is on. • The green Active LED on each connected BNC port is on. Model EN104/EN108/EN116 Ethernet Hub Installation Guide If encounter any problems, refer to "Troubleshooting" on page 4.
When power has been applied to the power outlet on the wall. Verify Installation To complete the installation, connect the power cord first to the power receptacle on the hub rear panel and then to the hub: • The green Pwr (Power) LED on the front panel is on. • The green Link LED on each connected port is on. • The green Active LED on each connected AUI port is on. • The green Active LED on each connected BNC port is on. Model EN104/EN108/EN116 Ethernet Hub Installation Guide If encounter any problems, refer to "Troubleshooting" on page 4.
EN104 Installation Guide
Page 14
...half-duplex mode. Make sure that your transceiver documentation for instructions on when the port is data transmission. Model EN104/EN108/EN116 Ethernet Hub Installation Guide There is not detecting data transmission. The hub is not compatible with a BNC 50 terminator at a time to both ends. If you may have... SQE. Check for a bad cable, cable pairs that are segment the network with an Ethernet switch such connected on the as a NETGEAR Ethernet switch or to upgrade network that there is terminated with devices that each segment is power to isolate the defective unit on the...
...half-duplex mode. Make sure that your transceiver documentation for instructions on when the port is data transmission. Model EN104/EN108/EN116 Ethernet Hub Installation Guide There is not detecting data transmission. The hub is not compatible with a BNC 50 terminator at a time to both ends. If you may have... SQE. Check for a bad cable, cable pairs that are segment the network with an Ethernet switch such connected on the as a NETGEAR Ethernet switch or to upgrade network that there is terminated with devices that each segment is power to isolate the defective unit on the...
EN104 Installation Guide
Page 15
Network Interface Cards Make sure the network interface cards installed in the workstations are in your area, refer to the hub off and then back on. If the problem continues and you have been installed. For the phone number of the hub by resetting it. Hub Integrity If required, verify the integrity of the representative in working condition and the software drivers have completed all the preceding diagnoses, contact NETGEAR Customer Support. Model EN104/EN108/EN116 Ethernet Hub Installation Guide Turn power to the Support Information Card.
Network Interface Cards Make sure the network interface cards installed in the workstations are in your area, refer to the hub off and then back on. If the problem continues and you have been installed. For the phone number of the hub by resetting it. Hub Integrity If required, verify the integrity of the representative in working condition and the software drivers have completed all the preceding diagnoses, contact NETGEAR Customer Support. Model EN104/EN108/EN116 Ethernet Hub Installation Guide Turn power to the Support Information Card.
EN104 Installation Guide
Page 16
... (UL 1950) CUL TUV licensed (EN 60 950) T-Mark Model EN104/EN108/EN116 Ethernet Hub Installation Guide Technical Specifications General Specifications Network Protocol and Standards Compatibility IEEE 802.3i, 10BASE-T, 10BASE-2, 10BASE-5 Ethernet Data Rate 10 Mbps, Manchester encoded Interface 10BASE-T ports (RJ-45), BNC port, AUI port (Model EN108 hub and Model EN116 hub only) Max.
... (UL 1950) CUL TUV licensed (EN 60 950) T-Mark Model EN104/EN108/EN116 Ethernet Hub Installation Guide Technical Specifications General Specifications Network Protocol and Standards Compatibility IEEE 802.3i, 10BASE-T, 10BASE-2, 10BASE-5 Ethernet Data Rate 10 Mbps, Manchester encoded Interface 10BASE-T ports (RJ-45), BNC port, AUI port (Model EN108 hub and Model EN116 hub only) Max.
EN104 Installation Guide
Page 17
...DC, 1 A), Australia Power adapter (7.5 V DC, 1 A), Japan Order code PWR-002-004 PWR-002-005 PWR-002-006 PWR-002-008 PWR-002-010 EN108, EN116 Power adapter (12 V DC, 1.2 A), North America Power adapter (12 V DC, 1.2 A), Japan Power adapter (12 V DC, 1.2 A), Europe Power... DC, 1.2 A), United Kingdom Power adapter (12 V DC, 1.2 A), Australia Model EN104/EN108/EN116 Ethernet Hub Installation Guide Replacement Power Adapter If, for any reason, the power adapter for any of the hubs fails, contact NETGEAR immediately to order a replacement adapter. Use the following table when ordering a speci...
...DC, 1 A), Australia Power adapter (7.5 V DC, 1 A), Japan Order code PWR-002-004 PWR-002-005 PWR-002-006 PWR-002-008 PWR-002-010 EN108, EN116 Power adapter (12 V DC, 1.2 A), North America Power adapter (12 V DC, 1.2 A), Japan Power adapter (12 V DC, 1.2 A), Europe Power... DC, 1.2 A), United Kingdom Power adapter (12 V DC, 1.2 A), Australia Model EN104/EN108/EN116 Ethernet Hub Installation Guide Replacement Power Adapter If, for any reason, the power adapter for any of the hubs fails, contact NETGEAR immediately to order a replacement adapter. Use the following table when ordering a speci...
EN104 Installation Guide
Page 18
...EN 55 022 Statement This is used in a residential area or in an adjacent area thereto, radio interference may occur due to the products described in the BMPT-AmtsblVfg 243/1991 and Vfg 46/ 1992. Canadian Department of Communications Radio Interference Regulations This digital apparatus (NETGEAR Model EN104 hub, Model EN108 hub, and Model EN116 hub...subject to take appropriate measures. Windows® is hereby certified that the NETGEAR Model EN104 hub, Model EN108 hub, and Model EN116 hub are aimed at their respective holders. Information is in the first category (...
...EN 55 022 Statement This is used in a residential area or in an adjacent area thereto, radio interference may occur due to the products described in the BMPT-AmtsblVfg 243/1991 and Vfg 46/ 1992. Canadian Department of Communications Radio Interference Regulations This digital apparatus (NETGEAR Model EN104 hub, Model EN108 hub, and Model EN116 hub...subject to take appropriate measures. Windows® is hereby certified that the NETGEAR Model EN104 hub, Model EN108 hub, and Model EN116 hub are aimed at their respective holders. Information is in the first category (...