EL1SS Repair Parts Instructions Manual
Page 1
...the screws (4) securing the existing logic board from the logic board. Reattach the faceplate to the housing and set aside. Reconnect power to LiftMaster. 7. If applicable, return the logic board to the unit. 15. Position the new logic board on a flat surface and prop the... Disconnect electric power at the fuse box BEFORE proceeding. • ALL electrical connections MUST be returned to the logic board. 13. EL1SS TELEPHONE ENTRY SYSTEM REPAIR PARTS INSTRUCTIONS Replace the Logic Board NOTE: After the new logic board is reconnected. If applicable, carefully remove ...
...the screws (4) securing the existing logic board from the logic board. Reattach the faceplate to the housing and set aside. Reconnect power to LiftMaster. 7. If applicable, return the logic board to the unit. 15. Position the new logic board on a flat surface and prop the... Disconnect electric power at the fuse box BEFORE proceeding. • ALL electrical connections MUST be returned to the logic board. 13. EL1SS TELEPHONE ENTRY SYSTEM REPAIR PARTS INSTRUCTIONS Replace the Logic Board NOTE: After the new logic board is reconnected. If applicable, carefully remove ...
EL1SS Sell Sheet Manual
Page 1
...steel faceplate with visitors, grant or deny access, all at the gate or door. D © 2015 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMTECAEL1S 7/15 Safety and Security • Vacation mode locks the system down when no additional monthly ...CODES 200 (4- W x 6-1/4 in . Durability. pad mount pedestal, the 2x2 in . steel for long lasting durability. The LiftMaster® EL1SS Telephone Intercom and Access Control System provides wired telephone intercom communication and secure access control at an exceptional value. With the...
...steel faceplate with visitors, grant or deny access, all at the gate or door. D © 2015 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMTECAEL1S 7/15 Safety and Security • Vacation mode locks the system down when no additional monthly ...CODES 200 (4- W x 6-1/4 in . Durability. pad mount pedestal, the 2x2 in . steel for long lasting durability. The LiftMaster® EL1SS Telephone Intercom and Access Control System provides wired telephone intercom communication and secure access control at an exceptional value. With the...
EL1SS Installation and Programming Manual
Page 13
... 75 - 150 feet 150 - 250 feet 250 - 500 feet AC POWER WIRE SIZE 18 AWG 18 AWG 18 AWG 16 AWG 12 AWG NOTE: LiftMaster is for proper depth Earth ground rod Other ground sources within 12 feet of access control panel Ground to metallic cold water pipe Ground to... cause damage to the unit only. Check local building codes before installation. 11 Dedicated 10 Amp Minimum Circuit Breaker 12 Vac Power (included) The EL1SS MUST be wired back to install the unit for conflicts between the information listed in most cases. INTRODUCTION INSTALLATION TESTING PROGRAMMING EARTH GROUND ROD To...
... 75 - 150 feet 150 - 250 feet 250 - 500 feet AC POWER WIRE SIZE 18 AWG 18 AWG 18 AWG 16 AWG 12 AWG NOTE: LiftMaster is for proper depth Earth ground rod Other ground sources within 12 feet of access control panel Ground to metallic cold water pipe Ground to... cause damage to the unit only. Check local building codes before installation. 11 Dedicated 10 Amp Minimum Circuit Breaker 12 Vac Power (included) The EL1SS MUST be wired back to install the unit for conflicts between the information listed in most cases. INTRODUCTION INSTALLATION TESTING PROGRAMMING EARTH GROUND ROD To...