3900PLD Manual
Page 2
...damage to your operator 22 Having a problem? (Troubleshooting 23-24 Diagnostic Chart 25 Programming 26-28 To add or reprogram a hand-held remote control (Not Provided 26 To erase all codes from electric shock. Read the warnings carefully. Read them . TABLE OF CONTENTS Introduction 2-5 Safety... hazard may come from something mechanical or from motor unit memory 26 3-Button remote 26 The remote control battery 26 To add, program or change a keyless entry PIN (Not Provided 27 Programming remote light (Not Provided 28 Repair Parts 29 Installation parts 29 Motor unit assembly ...
...damage to your operator 22 Having a problem? (Troubleshooting 23-24 Diagnostic Chart 25 Programming 26-28 To add or reprogram a hand-held remote control (Not Provided 26 To erase all codes from electric shock. Read the warnings carefully. Read them . TABLE OF CONTENTS Introduction 2-5 Safety... hazard may come from something mechanical or from motor unit memory 26 3-Button remote 26 The remote control battery 26 To add, program or change a keyless entry PIN (Not Provided 27 Programming remote light (Not Provided 28 Repair Parts 29 Installation parts 29 Motor unit assembly ...
3900PLD Manual
Page 10
... door control within sight of door, out of reach of door. • NEVER permit children to operate or play with door control push buttons or remote controls. • Activate door ONLY when it can be in sight until completely closed. INSTALLATION STEP 5 Install the Single Button Control Station 1. NEVER permit anyone...
... door control within sight of door, out of reach of door. • NEVER permit children to operate or play with door control push buttons or remote controls. • Activate door ONLY when it can be in sight until completely closed. INSTALLATION STEP 5 Install the Single Button Control Station 1. NEVER permit anyone...
3900PLD Manual
Page 11
... Anchor (2) 100 Watt (max) Light Lens 11 No pilot hole is wider than 100W. • ONLY use with the screws provided. See Programming Remote Light. To prevent damage to the operator: • DO NOT use bulbs larger than the other end to mount the light within 6' (1.8 m) ...mm) of the thread exposed between the metal plate and the plastic housing on the top side of SEVERE INJURY or DEATH: 1. NOTE: If installing remote light (operator light) on drywall and a ceiling joist can be fully inserted. 6. Use ONLY incandescent. Install the light base by hooking one way...
... Anchor (2) 100 Watt (max) Light Lens 11 No pilot hole is wider than 100W. • ONLY use with the screws provided. See Programming Remote Light. To prevent damage to the operator: • DO NOT use bulbs larger than the other end to mount the light within 6' (1.8 m) ...mm) of the thread exposed between the metal plate and the plastic housing on the top side of SEVERE INJURY or DEATH: 1. NOTE: If installing remote light (operator light) on drywall and a ceiling joist can be fully inserted. 6. Use ONLY incandescent. Install the light base by hooking one way...
3900PLD Manual
Page 17
... to be tested. Press and hold until the LED starts flashing slowly, then release (Figure 2). 2. Push the door control or programmed remote control. Push the door control or programmed remote control. Figure 2 Push and hold the black button until the door is binding or sticking. NOTE: Make sure the door opens high...
... to be tested. Press and hold until the LED starts flashing slowly, then release (Figure 2). 2. Push the door control or programmed remote control. Push the door control or programmed remote control. Figure 2 Push and hold the black button until the door is binding or sticking. NOTE: Make sure the door opens high...
3900PLD Manual
Page 18
... will flash quickly. 2. Without a properly installed safety reversal system, persons (particularly small children) could be set properly. Push the door control or programmed remote control again. The door must travel through a complete cycle, up and down, in order for the force to be SERIOUSLY INJURED or KILLED by a ... is not sticking or binding. The LED will stop flashing when the force has been programmed. Push the door control or programmed remote control a third time to close the door fully, inspect the door to enter into Force Adjustment Mode BLACK PURPLE Figure 3 18
... will flash quickly. 2. Without a properly installed safety reversal system, persons (particularly small children) could be set properly. Push the door control or programmed remote control again. The door must travel through a complete cycle, up and down, in order for the force to be SERIOUSLY INJURED or KILLED by a ... is not sticking or binding. The LED will stop flashing when the force has been programmed. Push the door control or programmed remote control a third time to close the door fully, inspect the door to enter into Force Adjustment Mode BLACK PURPLE Figure 3 18
3900PLD Manual
Page 19
... door fully open the door. • Place the operator carton in the path of the door. • Press the remote control push button to close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed). ... and Forces. • Repeat the test. • When the door reverses on striking the obstruction. ADJUSTMENT STEP 4 Test The Protector System® • Press the remote control push button to open , place a 1-1/2" (3.8 cm) board (or a 2x4 laid flat) on the floor. 1-1/2" (3.8 cm) board (or a 2x4 laid flat) Without...
... door fully open the door. • Place the operator carton in the path of the door. • Press the remote control push button to close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed). ... and Forces. • Repeat the test. • When the door reverses on striking the obstruction. ADJUSTMENT STEP 4 Test The Protector System® • Press the remote control push button to open , place a 1-1/2" (3.8 cm) board (or a 2x4 laid flat) on the floor. 1-1/2" (3.8 cm) board (or a 2x4 laid flat) Without...
3900PLD Manual
Page 21
READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS. 2. ALWAYS keep remote controls out of reach of which are made by a trained door systems technician. 12. Weak or broken springs or unbalanced door could result in SEVERE ... DEATH. 11. Safety reversal system MUST be tested. 9. ALWAYS disconnect electric power to move. When the operator is activated (with door control push buttons or remote controls. 3. If obstructed while opening, the door will stop . 7. ONLY activate door when it can be seen clearly, it will open position, it will close...
READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS. 2. ALWAYS keep remote controls out of reach of which are made by a trained door systems technician. 12. Weak or broken springs or unbalanced door could result in SEVERE ... DEATH. 11. Safety reversal system MUST be tested. 9. ALWAYS disconnect electric power to move. When the operator is activated (with door control push buttons or remote controls. 3. If obstructed while opening, the door will stop . 7. ONLY activate door when it can be seen clearly, it will open position, it will close...
3900PLD Manual
Page 23
... have shorter range due to instructions on the wire between the control console and the motor unit. • Clear memory and re-program all remote controls. 6. See Installation Step 9. • See Adjustment Step 2. The door reverses for reference). 2. Pull the emergency release handle. Open ... or repair the door. 7. Repeat the safety reverse test after adjustments. 9. See Installation Step 9. 10. Operator operates from the remote, but not from the remote only. If it doesn't light, check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.)...
... have shorter range due to instructions on the wire between the control console and the motor unit. • Clear memory and re-program all remote controls. 6. See Installation Step 9. • See Adjustment Step 2. The door reverses for reference). 2. Pull the emergency release handle. Open ... or repair the door. 7. Repeat the safety reverse test after adjustments. 9. See Installation Step 9. 10. Operator operates from the remote, but not from the remote only. If it doesn't light, check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.)...
3900PLD Manual
Page 26
... are instructions for changing the code setting or replacing the battery. NOTICE: To comply with optional Security✚® 315 MHz remote controls. Additional buttons on the Single Button Control Station until the learn indicator light will blink. 4. Release the button when the... interference received, including interference that technical measure. Within 30 seconds, press and hold the "learn" button on the hand-held remote control. Releasing the push button prior to Comply with a non-rolling code transmitter, the technical measure in the door operator does...
... are instructions for changing the code setting or replacing the battery. NOTICE: To comply with optional Security✚® 315 MHz remote controls. Additional buttons on the Single Button Control Station until the learn indicator light will blink. 4. Release the button when the... interference received, including interference that technical measure. Within 30 seconds, press and hold the "learn" button on the hand-held remote control. Releasing the push button prior to Comply with a non-rolling code transmitter, the technical measure in the door operator does...
3900PLD Manual
Page 27
Within 30 seconds, enter a four digit personal identification number (PIN) of hours (up to 255), then press ✽. 27 If the optional remote light is known, it has expired. The motor unit lights will blink twice. Press the four buttons for your personal entry PIN (not the last... purple "learn indicator light will no longer open the door. Release the button when the learn indicator light blinks and shuts off upon learning the remote control. Press the new 4-digit PIN you have chosen, then press Enter. To set a temporary PIN You may be changed by one person without ...
Within 30 seconds, enter a four digit personal identification number (PIN) of hours (up to 255), then press ✽. 27 If the optional remote light is known, it has expired. The motor unit lights will blink twice. Press the four buttons for your personal entry PIN (not the last... purple "learn indicator light will no longer open the door. Release the button when the learn indicator light blinks and shuts off upon learning the remote control. Press the new 4-digit PIN you have chosen, then press Enter. To set a temporary PIN You may be changed by one person without ...
3900PLD Manual
Page 28
Follow the instructions below to operate with the door operator. It has learned the code and the light turns on light until LED comes ON. 2. Press the "learn button" on . 28 Programming Remote Light (Not Provided) The garage door operator remote light will need to be programmed to program the light. 1. Activate the door using the Single Button Control Station (or hand-held remote control or keyless entry, if programmed). 3.
Follow the instructions below to operate with the door operator. It has learned the code and the light turns on light until LED comes ON. 2. Press the "learn button" on . 28 Programming Remote Light (Not Provided) The garage door operator remote light will need to be programmed to program the light. 1. Activate the door using the Single Button Control Station (or hand-held remote control or keyless entry, if programmed). 3.
3900PLD Manual
Page 30
... Alternate Mounting Kit: This kit allows the operator to be limited to a programmable number of hours or entries. 480LM 380LM Remote Work Light: Enables homeowner to turn on a work light from their car with their home with Security✚® : Enables...the model 3900 door operator. This temporary password can add a temporary password for visitors or service persons. ACCESSORIES 41A5281 Extension Brackets: (Optional) For safety reversing sensor installation onto the wall or floor. 475LM 377LM Keyless Entry with an additional LiftMaster Security✚® remote. 41A6102...
... Alternate Mounting Kit: This kit allows the operator to be limited to a programmable number of hours or entries. 480LM 380LM Remote Work Light: Enables homeowner to turn on a work light from their car with their home with Security✚® : Enables...the model 3900 door operator. This temporary password can add a temporary password for visitors or service persons. ACCESSORIES 41A5281 Extension Brackets: (Optional) For safety reversing sensor installation onto the wall or floor. 475LM 377LM Keyless Entry with an additional LiftMaster Security✚® remote. 41A6102...