IBM 86802SY - Netfinity 7000 M10 Support and Manuals
Popular IBM 86802SY Manual Pages
Hardware Maintenance Manual - Page 9
... 28 Using the Power-On Password Menu . . . 29 Using the Administrator Password Menu . 31 Start Options 32 Advanced Setup 32 ACPI Control 32 Cache Control 33 PCI Slot/Device Information 33 Memory Settings 33 MPS Version Control 34 Error Logs 34 POST Error Log 34 System Error Log 34 Save Settings 34
© Copyright IBM Corp. 1998
1 Netfinity 7000-M10 -
Hardware Maintenance Manual - Page 12
... Network Adapters and Device Drivers 181 Symptom-to-FRU Index 182 Beep Symptoms 182 No Beep Symptoms 186 Diagnostic Error Codes 187 Error Symptoms 192 Power Control Card LED 194 Power Supply LED Errors 194 POST Error Codes 195 Processor Board LEDs 202 SCSI LEDs 203 SCSI Error Codes 203 SMBUS Error (3-3-2 204 Undetermined Problems 205 System Management Codes 208
4 Netfinity Server...
Hardware Maintenance Manual - Page 17
... following : Checks the operation of the options installed in the server. These programs are stored on self-test or POST. When this occurs, work to help identify and resolve hardware-related problems:
Diagnostic programs Power-on self-test (POST) POST beep codes Error messages Troubleshooting charts System error log Option diskettes
Diagnostic Programs: The server diagnostic...
Hardware Maintenance Manual - Page 21
...error will load. If you do not find a problem but the problem persists during testing and you cannot run the programs. You can only view the error messages in the appropriate password; If the server is set..., follow the instructions on page 205. 4. Type 8680 13 If the diagnostic tests do not have to install a wrap connector on password or administrator password is turned on...
Hardware Maintenance Manual - Page 37
...on prompt. (If necessary, see steps 1 through 4 on the Configuration/Setup Utility main menu.
Netfinity 7000-M10 - system.
You can set of Password No password set , enter the administrator password at the power-on password. You must enter a password each time that you enter the correct password. The administrator password provides access to be changed by the user. If you enter...
Hardware Maintenance Manual - Page 43
... configuration settings. Install software programs. See the installation instructions that might be required to determine the steps that comes with the adapter.
4. The following list provides a preview of the actions that come with it. Reading the instructions helps you to configure the server.
1. See "The Configuration/Setup Utility Program" on page 173.
5. Netfinity 7000-M10...
Hardware Maintenance Manual - Page 53
... to create the diskettes. To install the device drivers with the CoPilot ApplicationGuide CD follow the instructions provided in one of supported operating systems, see http://www.pc.ibm.com/us/netfinity/ on the ApplicationGuide CoPilot CD to finish installing your device drivers. Insert the diskette labelled IBM Netfinity 7000-M10 Device Drivers for Advanced System Management, version...
Hardware Maintenance Manual - Page 73
...system components monitored by IBM servicers in the system management subsystem ...Management Subsystem Logs window:
Load
Refreshes the contents of system problems.
2.
Available values include:
Power supply voltages (including +5...service with an Netfinity Advanced System Management PCI Adapter installed in a Netfinity 7000 server, the event log might contain entries that begin with a Netfinity 7000...
Hardware Maintenance Manual - Page 146
... support hot-swap drives only. You might also need to the information that comes with the internal drive. Remove any other equipment specified in which you need to install the drive. 2. Installing ... SCSI backplane is set any steps that control termination.
Some of the steps are required only during the initial installation of an option.
1. Check the instructions that you have ...
Hardware Maintenance Manual - Page 187
... with your operating system. Set any cables to server components or the adapter. Install the adapter: a. Press the adapter firmly into the expansion slot. Lower the tab 1 over the adapter. Netfinity 7000-M10 - Attention: Expansion-slot covers must be installed on a flat, static-protective surface.
8. Refer to route any cabling instructions. Carefully grasp the adapter...
Hardware Maintenance Manual - Page 189
...-side up, on page 97. Install the adapter: a. d. e. Netfinity 7000-M10 - Set any cables to server components or the adapter. b. Press the adapter firmly into the expansion slot. Refer to your network-adapter documentation for operation of the server.
Verifying Compatibility between Network Adapters and Device Drivers: Your server
supports several types of a network adapter...
Hardware Maintenance Manual - Page 190
...
182 Netfinity Server HMM Check the configuration before you decide which FRUs to the manual for that device. 3.
I /O Board
1. Symptom-to -FRU Index lists symptoms, errors, and the possible causes. The Symptom-to -FRU Index
This index supports Netfinity 7000-M10 -
Note One beeps after successfully completing POST indicated the system is listed first...
Hardware Maintenance Manual - Page 220
...Server HMM
Table 15 (Page 4 of 4). PCI related error: a. Processor Board
C1 (Memory)
1. Replace the FRU for the error in the log. 2. See system error log to determine which DIMM failed on which card. System Management Codes
Code/Description
FRU/Action
C0 (SMI error)
1. See the system error log and follow the instruction for the following problems listed.
Memory Board c.
Hardware Maintenance Manual - Page 244
...model of these parts, contact an IBM service technician.
To avoid personal injury or equipment damage, disconnect the attached power cords, telecommunications systems, networks, and modems before you suspect a problem...and energy levels are no serviceable parts inside the power supplies, power backplane, and AC box. If you open the server covers, unless instructed otherwise in the server; ...
Installation Guide - Page 14
... and it is starting without errors, install the additional network adapters one at a time makes locating a defective adapter much easier.
2 Use the tables provided in this Server
Library to: Update the "Hardware Information" device-records tables with
"Software Installation" on page 13.
12 Netfinity 7000 M10 Express Setup and Installation Installing Additional Options
If you have additional...
IBM 86802SY Reviews
Do you have an experience with the IBM 86802SY that you would like to share?
Earn 750 points for your review!
We have not received any reviews for IBM yet.
Earn 750 points for your review!