Hardware Maintenance Manual - Page 9

IBM Netfinity 3000 - Type 8476 General Checkout 4 Diagnostics 6 Diagnostic test programs 7 Power-on self-test (POST 8 POST beep codes 9 Error messages 9 POST error messages and beep codes . . . 9 SCSI error messages 9 Diagnostic error messages 9 Software-generated error messages . . . . . 10 Installing files from option diskettes 10 Running the diagnostic test programs 11 Power-on ...
Hardware Maintenance Manual - Page 17

... application program indicates successful completion of complex problems indicated by error messages should be used to identify a failing part. For a list of error codes, see "Symptom-to -FRU index" on the screen. For a list of beep codes, see "Symptom-to -FRU index" on page 160. Type 8476 9 IBM Netfinity 3000 - POST beep codes If Power-On Status is detected...
Hardware Maintenance Manual - Page 20

... Arrow (↓) key to view the error codes and error code descriptions that are malfunctioning or that the POST Startup Errors screen does not appear immediately. In the case of the passwords at the password prompt. When the Configuration/Setup Utility program starts, a screen titled POST Startup Errors appears. (Note that have the password prompt set both power-on and administrator...
Hardware Maintenance Manual - Page 21

... problem with the startup device). When you select Save Settings and then exit from the Configuration/Setup Utility program menu (see "Symptom-to the Configuration/Setup Utility program menu. You will get an error message if you exit from the Configuration/Setup Utility program. To exit from the Configuration/Setup Utility program, press Esc and follow the instructions...
Hardware Maintenance Manual - Page 29

... change the memory-address space used by some hardware options. You need to change the settings. Always run the Configuration/Setup Utility program if you receive an error message instructing you installed or removed SCSI devices, run and exit the Configuration/Setup Utility program, configuration information is to do so. conflict occurs, and the device will...
Hardware Maintenance Manual - Page 30

...POST Startup Error(s) The following error(s) were detected when the system was started: 162 Configuration Change Has Occurred Select one of the following: Continue Exit Setup Note Depending...prompted to enter the Configuration/Setup Utility program to manually update the configuration settings or to enter Configuration/Setup appears, press F1. The Configuration/Setup Utility program menu appears....
Hardware Maintenance Manual - Page 37

... normal operation. However, if you will not be able to access the Configuration/Setup Utility program. IBM Netfinity 3000 - If you must type the administrator password at this mode when power is restored, without operator intervention. If you type the wrong password three times, you start the server, the server operates the same as a modem...
Hardware Maintenance Manual - Page 42

... instructions on the World Wide Web and download the appropriate flash update program. then, press Enter. 4. Note The server supports IDE CD-ROM drives. Go to perform POST and BIOS updates. From the Configuration/Setup Utility program menu, select System Security; Consult the network administrator for information on setting up the network server to http://www.ibm...
Hardware Maintenance Manual - Page 44

...known as Processor 0 ID and Processor Updating. However, many ISA adapters are no switches or jumpers that must manually configure it by setting switches or jumpers on the adapter,...with configuration specifications set on page 20 for Plug and Play is a configuration method that are auto-configuring. If you install a legacy adapter, you must be set in use . Support for information...
Hardware Maintenance Manual - Page 46

...support auto-negotiation will not attach to the Netfinity 3000 server in the network must manually override the settings to the Ethernet documentation for instructions on installing device drivers... full duplex (FDX). ServerGuide includes IBM Update Connector, which the server is connected also supports auto-negotiation. However, except for instructions on a standard Ethernet system can ...
Hardware Maintenance Manual - Page 55

.... To set the ROM operation mode to the appropriate value, set the switch. Normal ROM Operation 12345678 ON OFF ROM Recovery Mode 12345678 ON OFF 3. IBM Netfinity 3000 - Review...ibm.com/support/ on page 142. 2. Create a Flash Utility Diskette, see "System board illustration" on the World Wide Web and download the appropriate flash update program. ROM operation mode switch setting...
Hardware Maintenance Manual - Page 140

...The microprocessor in this section. 2. For information about the appropriate switch settings, see "Microprocessor speed switches settings" on the top of the system board illustration. Place your index fingers... board illustration" on the system board and is referred to the system board. To install a microprocessor: 1. Remove the server side cover (see the label inside the server....
Hardware Maintenance Manual - Page 159

To run the Configuration/Setup Utility program, follow the instructions in the startup sequence, use . When you install an ISA legacy adapter, you do not need to install device drivers after you install or replace options, or after you restart the server, you update the configuration settings. Make a record of the Configuration/Setup Utility program (see "Start options" on page 36...
Hardware Maintenance Manual - Page 171

... 217.) 3. Time and Date Set? 2. System Board 1. Processor IBM Netfinity 3000 - Reseat adapters 2. CMOS Backup Battery (See page 217.) 5. Adapter Memory 2. POST error codes POST Error Code/Symptom 101 System board interrupt failure. 102 System board timer error. 106 110 System board memory parity error. 111 I/O channel parity error. 114 Adapter ROM error. 151 Real-time clock failure...
Hardware Maintenance Manual - Page 233

...whenever the fan assembly is not installed in the installation and configuration procedures. There are no serviceable parts inside the power supplies, power ...problem with one of the server. Caution: Never remove the cover on a power supply or any object weighing more than 50 kg (110 lbs) on top of the rack model of these parts, contact an IBM service technician. Related service...

IBM 847670U Reviews

Do you have an experience with the IBM 847670U that you would like to share?
Earn 750 points for your review!
We have not received any reviews for IBM yet.

Popular IBM 847670U Search Terms

The following terms are frequently used to search for IBM 847670U support:

Ask a New Question
Use the box below to post a new question about IBM 847670U.
Manuals / Documents
Download any of our IBM 847670U manuals for free!

We have the following 1 documents available for the IBM 847670U:
  • Hardware Maintenance Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

IBM Manuals

Find free IBM 847670U - Netfinity 3000 - 70U manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

IBM Reviews

View thousands of IBM 847670U - Netfinity 3000 - 70U user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete IBM customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed IBM customer service rankings, employee comments and much more from our sister site.

IBM Recalls

Find comprehensive IBM recall information updated hourly on RecallOwl.com.