Hardware Maintenance Manual
Page 6
... Sie alle Sicherheitshinweise, bevor Sie eine Anweisung ausführen. Online support Use the IBM Personal computing solutions (BBS) or the World Wide Web (WWW) to download Diagnostic, BIOS Flash, and Device Driver files. http://www.ibm.com/pc/ iv Netfinity Server HMM Accertarsi di leggere tutti gli avvisi di attenzione e di pericolo prima...
... Sie alle Sicherheitshinweise, bevor Sie eine Anweisung ausführen. Online support Use the IBM Personal computing solutions (BBS) or the World Wide Web (WWW) to download Diagnostic, BIOS Flash, and Device Driver files. http://www.ibm.com/pc/ iv Netfinity Server HMM Accertarsi di leggere tutti gli avvisi di attenzione e di pericolo prima...
Hardware Maintenance Manual
Page 26
... server, the more you can obtain a listing of products that are compatible with the following World Wide Web address: http://www.ibm.com/pc/us/compat/ Jumpers and switches are used to configure the server depend on adapters, drives, or other devices. Configuration ... standards: Peripheral Component Interconnect (PCI) Industry Standard Architecture (ISA) Small Computer System Interface (SCSI) Accelerated Graphics Port (AGP) You can configure system board functions, such as configuration. Reading the instructions 18 Netfinity Server HMM If you install in the server. The steps required to...
... server, the more you can obtain a listing of products that are compatible with the following World Wide Web address: http://www.ibm.com/pc/us/compat/ Jumpers and switches are used to configure the server depend on adapters, drives, or other devices. Configuration ... standards: Peripheral Component Interconnect (PCI) Industry Standard Architecture (ISA) Small Computer System Interface (SCSI) Accelerated Graphics Port (AGP) You can configure system board functions, such as configuration. Reading the instructions 18 Netfinity Server HMM If you install in the server. The steps required to...
Hardware Maintenance Manual
Page 53
... above are controlled by the System Management Controller and the power supply fan is not. If the power-on indicator is not running, or the computer will not power-off, do the following for proper installation. Power supply Note The Front Fan and Disk Fan A are correct, check the following voltages... the system board or riser card. 1 10 11 Pin Signal 1 3.3 V 2 3.3 V 3 COM 4 5 V 5 COM 6 5 V 7 COM 8 POK 20 Function +3.3 V dc +3.3 V dc Ground +5 V dc Ground +5 V dc Ground Power Good IBM Netfinity 3000 -
... above are controlled by the System Management Controller and the power supply fan is not. If the power-on indicator is not running, or the computer will not power-off, do the following for proper installation. Power supply Note The Front Fan and Disk Fan A are correct, check the following voltages... the system board or riser card. 1 10 11 Pin Signal 1 3.3 V 2 3.3 V 3 COM 4 5 V 5 COM 6 5 V 7 COM 8 POK 20 Function +3.3 V dc +3.3 V dc Ground +5 V dc Ground +5 V dc Ground Power Good IBM Netfinity 3000 -
Hardware Maintenance Manual
Page 64
...operate. The declared sound power levels indicate an upper limit, below the theoretical maximum. 56 Netfinity Server HMM Minimum: 180 V ac - The following table contains the environmental specifications for the Netfinity 3000 server. Minimum: 90 V ac - System on : 8% to 80% - Low range:... - Acoustical Noise-Emission Values Average sound-pressure levels: - Size Depth: 445 mm (17.5 in.) Width: 200 mm (7.9 in.) Height: 492 mm (19.4 in your location might exceed the average values stated because of computers...
...operate. The declared sound power levels indicate an upper limit, below the theoretical maximum. 56 Netfinity Server HMM Minimum: 180 V ac - The following table contains the environmental specifications for the Netfinity 3000 server. Minimum: 90 V ac - System on : 8% to 80% - Low range:... - Acoustical Noise-Emission Values Average sound-pressure levels: - Size Depth: 445 mm (17.5 in.) Width: 200 mm (7.9 in.) Height: 492 mm (19.4 in your location might exceed the average values stated because of computers...
Hardware Maintenance Manual
Page 97
... in one end, and the proper connector for the external device on the other computers. The bits-per second (bps) up to send 4 Data terminal ready 9 Ring indicator 5 Signal ground Table 2. device with the Netfinity 3000 server, you must have the proper connector for the SCSI external connector on one ...and receive data and commands at any number of bits at a rate of the pauses between characters. Serial Port Connector Pin-Number Assignments IBM Netfinity 3000 - Type 8476 89 The pin-number assignments conform to communicate with the external device, contact your...
... in one end, and the proper connector for the external device on the other computers. The bits-per second (bps) up to send 4 Data terminal ready 9 Ring indicator 5 Signal ground Table 2. device with the Netfinity 3000 server, you must have the proper connector for the SCSI external connector on one ...and receive data and commands at any number of bits at a rate of the pauses between characters. Serial Port Connector Pin-Number Assignments IBM Netfinity 3000 - Type 8476 89 The pin-number assignments conform to communicate with the external device, contact your...
Hardware Maintenance Manual
Page 112
... The SCSI device ID is connected to 15; The Netfinity 3000 server supports drives that the server supports, go to the integrated SCSI-2 connector. If you install additional SCSI devices, you connect to http://www.ibm.com/pc/us/netfinity/ on its LUN is based on the World Wide Web...UltraSCSI adapter, the devices compete for an internal SCSI hard disk drive in Channel A. SCSI drives: Some drives have a special design called small computer system interface (SCSI). SCSI physical unit numbers: When more information.) If you install wide (16-bit) SCSI devices, you can set the...
... The SCSI device ID is connected to 15; The Netfinity 3000 server supports drives that the server supports, go to the integrated SCSI-2 connector. If you install additional SCSI devices, you connect to http://www.ibm.com/pc/us/netfinity/ on its LUN is based on the World Wide Web...UltraSCSI adapter, the devices compete for an internal SCSI hard disk drive in Channel A. SCSI drives: Some drives have a special design called small computer system interface (SCSI). SCSI physical unit numbers: When more information.) If you install wide (16-bit) SCSI devices, you can set the...
Hardware Maintenance Manual
Page 139
... 131 Installing or replacing microprocessors: This section gives the procedure for the server through the World Wide Web and the IBM Personal Computer Company Bulletin Board System (BBS). Locate the Flash Utility Diskette that is greater than the actual frequency of the microprocessor...the appropriate World Wide Web addresses and bulletin board telephone numbers. IBM Netfinity 3000 - Read "Accessing the system board" on page 212. Perform the POST/BIOS (flash) update procedure (see http://www.ibm.com/pc/us/netfinity/ on the World Wide Web and download the appropriate flash update...
... 131 Installing or replacing microprocessors: This section gives the procedure for the server through the World Wide Web and the IBM Personal Computer Company Bulletin Board System (BBS). Locate the Flash Utility Diskette that is greater than the actual frequency of the microprocessor...the appropriate World Wide Web addresses and bulletin board telephone numbers. IBM Netfinity 3000 - Read "Accessing the system board" on page 212. Perform the POST/BIOS (flash) update procedure (see http://www.ibm.com/pc/us/netfinity/ on the World Wide Web and download the appropriate flash update...
Hardware Maintenance Manual
Page 168
... separated by index, refer to help you replace a FRU. Notes 1. Check the configuration before you decide which FRUs to -FRU index This index supports the Netfinity 3000 - For IBM devices not supported by pauses (intervals without sound). Check speaker connection. 3. Speaker 4. System Board 1. Beeps 1-2-X 4 Description One beep A pause (or break) Two...beeps Four beeps Beep/Symptom 1-1-3 CMOS read/write error 1-1-4 ROM BIOS check error FRU/Action 1. The Symptom-to enable. 2. System Board 160 Netfinity Server HMM Symptom-to have available when servicing the computer.
... separated by index, refer to help you replace a FRU. Notes 1. Check the configuration before you decide which FRUs to -FRU index This index supports the Netfinity 3000 - For IBM devices not supported by pauses (intervals without sound). Check speaker connection. 3. Speaker 4. System Board 1. Beeps 1-2-X 4 Description One beep A pause (or break) Two...beeps Four beeps Beep/Symptom 1-1-3 CMOS read/write error 1-1-4 ROM BIOS check error FRU/Action 1. The Symptom-to enable. 2. System Board 160 Netfinity Server HMM Symptom-to have available when servicing the computer.
Hardware Maintenance Manual
Page 171
...Board 1. System Board 1. If not, suspect that is not supported by the current POST/BIOS. System Board 1. Run the Extended Memory Diagnostic tests. 1. Processor IBM Netfinity 3000 - Memory Module 2. System Board 1. Run Setup and verify Configuration 2. Reseat adapters 2. CMOS Backup Battery (See page 217.) 3. POST error codes POST Error ...Update the Flash BIOS to the latest level 2. Time and Date Set? 2. Run Setup 2. Power-on external devices first, then power-on computer. 4. Check System Summary menu for memory size change. 2. FRU/Action 1. Any Adapter 3.
...Board 1. System Board 1. If not, suspect that is not supported by the current POST/BIOS. System Board 1. Run the Extended Memory Diagnostic tests. 1. Processor IBM Netfinity 3000 - Memory Module 2. System Board 1. Run Setup and verify Configuration 2. Reseat adapters 2. CMOS Backup Battery (See page 217.) 3. POST error codes POST Error ...Update the Flash BIOS to the latest level 2. Time and Date Set? 2. Run Setup 2. Power-on external devices first, then power-on computer. 4. Check System Summary menu for memory size change. 2. FRU/Action 1. Any Adapter 3.
Hardware Maintenance Manual
Page 172
...Administration password 2. C2 Security 1. Riser Card, if installed 1. System Board 1. System Board 1. Keyboard 2. System Board 164 Netfinity Server HMM This is information only, no 8603 error. FRU/Action 1. Run Configuration 2. Keyboard 3. Riser Card, if installed.... 1. System Board 1. Keyboard Cable 4. Keyboard Cable 3. System Board 3. Covers were removed from the computer. 1. System Board 2. System Board 1. Memory Test 2. Enter the administrator password 1. System Board 1. Memory Module 3. System Board 1....
...Administration password 2. C2 Security 1. Riser Card, if installed 1. System Board 1. System Board 1. Keyboard 2. System Board 164 Netfinity Server HMM This is information only, no 8603 error. FRU/Action 1. Run Configuration 2. Keyboard 3. Riser Card, if installed.... 1. System Board 1. Keyboard Cable 4. Keyboard Cable 3. System Board 3. Covers were removed from the computer. 1. System Board 2. System Board 1. Memory Test 2. Enter the administrator password 1. System Board 1. Memory Module 3. System Board 1....
Hardware Maintenance Manual
Page 199
... boot (startup) file name. Press Ctrl+Alt+Del to another computer, an error message generated by the TFTP session will contain a message prefix of 2). M91 MTFTP canceled by keystroke. M93 Unknown MTFTP parameter (operation code). M98 Cannot open timeout. CD-ROM Drive IBM Netfinity 3000 - M33 Unknown TFTP parameter (operation code). M40 DHCP canceled...
... boot (startup) file name. Press Ctrl+Alt+Del to another computer, an error message generated by the TFTP session will contain a message prefix of 2). M91 MTFTP canceled by keystroke. M93 Unknown MTFTP parameter (operation code). M98 Cannot open timeout. CD-ROM Drive IBM Netfinity 3000 - M33 Unknown TFTP parameter (operation code). M40 DHCP canceled...
Hardware Maintenance Manual
Page 203
...Check for interrupt conflicts with ISA devices. The PCI BIOS is securely attached. 2. Run the Configuration/Setup Utility program on another computer that the network cable is not configuring the Ethernet controller or adapter correctly. Make sure that you are found , reserve the...controller interrupt Utility as 0 or 255. Check Cables 3. The Configuration/Setup Utility program reports No PCI Bus. Type 8476 195 IBM Netfinity 3000 - The server stops running when loading device drivers. If conflicts are found , reserve the ISA interrupts (see "ISA legacy resources...
...Check for interrupt conflicts with ISA devices. The PCI BIOS is securely attached. 2. Run the Configuration/Setup Utility program on another computer that the network cable is not configuring the Ethernet controller or adapter correctly. Make sure that you are found , reserve the...controller interrupt Utility as 0 or 255. Check Cables 3. The Configuration/Setup Utility program reports No PCI Bus. Type 8476 195 IBM Netfinity 3000 - The server stops running when loading device drivers. If conflicts are found , reserve the ISA interrupts (see "ISA legacy resources...
Hardware Maintenance Manual
Page 206
...adapter from the system, and replacing that adapter does not correct the problem, suspect the system board then the processor board(s). 198 Netfinity Server HMM Notes If you suspect a software mismatch is inoperative. If the LEDs indicate the power supplies are here because the ...List is incorrect, or the system is causing failures (solid or intermittent), be sure to see "Configuration conflicts" on the computer) Modem, printer, mouse, or non-IBM devices Each adapter Drives Memory-Module Kits (Minimum requirement = 1 bank of 64 MB DIMMs) Note Minimum operating requirements vary ...
...adapter from the system, and replacing that adapter does not correct the problem, suspect the system board then the processor board(s). 198 Netfinity Server HMM Notes If you suspect a software mismatch is inoperative. If the LEDs indicate the power supplies are here because the ...List is incorrect, or the system is causing failures (solid or intermittent), be sure to see "Configuration conflicts" on the computer) Modem, printer, mouse, or non-IBM devices Each adapter Drives Memory-Module Kits (Minimum requirement = 1 bank of 64 MB DIMMs) Note Minimum operating requirements vary ...
Hardware Maintenance Manual
Page 219
and Canada 258 Trademarks 260 © Copyright IBM Corp. 2000 211 Safety information 212 General safety 212 Electrical safety 213 Safety inspection guide 214 Handling electrostatic discharge-sensitive devices 216 Grounding requirements 216 ... procedures are designed to help you isolate problems. They are written with the assumption that you have model-specific training on all computers, or that are familiar with the computers, functions, terminology, and service information provided in this supplement and the PS/2 Hardware Maintenance Manual (part number 83G8990, form number S52G-9971...
and Canada 258 Trademarks 260 © Copyright IBM Corp. 2000 211 Safety information 212 General safety 212 Electrical safety 213 Safety inspection guide 214 Handling electrostatic discharge-sensitive devices 216 Grounding requirements 216 ... procedures are designed to help you isolate problems. They are written with the assumption that you have model-specific training on all computers, or that are familiar with the computers, functions, terminology, and service information provided in this supplement and the PS/2 Hardware Maintenance Manual (part number 83G8990, form number S52G-9971...
Hardware Maintenance Manual
Page 220
... muscles; Never move suddenly or twist when you start the machine, ensure that might be hazardous to the customer. 212 Netfinity Server HMM Before you attempt to ensure general safety: Observe good housekeeping in the moving parts of the machines during and after... maintenance. Ensure that can stand safely without slipping. 2. After service, reinstall all covers correctly before servicing an IBM mobile computer. Reinstall all safety shields, guards, labels, and ground wires. Use a slow lifting force. Do not wear loose clothing that your...
... muscles; Never move suddenly or twist when you start the machine, ensure that might be hazardous to the customer. 212 Netfinity Server HMM Before you attempt to ensure general safety: Observe good housekeeping in the moving parts of the machines during and after... maintenance. Ensure that can stand safely without slipping. 2. After service, reinstall all covers correctly before servicing an IBM mobile computer. Reinstall all safety shields, guards, labels, and ground wires. Use a slow lifting force. Do not wear loose clothing that your...
Hardware Maintenance Manual
Page 223
...and frame ground. Check that the power-supply cover fasteners (screws or rivets) have not been removed or tampered with the power off the computer. Explosive hazards, such as a damaged CRT face or bulging capacitor Mechanical hazards, such as to measure third-wire ground continuity for worn,..., or pinched cables. 8. Use a meter to the safety of fire or smoke damage. 7. Check inside the unit for any obvious non-IBM alterations. Consider these conditions and the safety hazards they present: Electrical hazards, especially primary power (primary voltage on the frame can cause serious or...
...and frame ground. Check that the power-supply cover fasteners (screws or rivets) have not been removed or tampered with the power off the computer. Explosive hazards, such as a damaged CRT face or bulging capacitor Mechanical hazards, such as to measure third-wire ground continuity for worn,..., or pinched cables. 8. Use a meter to the safety of fire or smoke damage. 7. Check inside the unit for any obvious non-IBM alterations. Consider these conditions and the safety hazards they present: Electrical hazards, especially primary power (primary voltage on the frame can cause serious or...
Hardware Maintenance Manual
Page 224
...a charge even when you use coax or connector-outside shells on ac-operated computers. Use the round ground-prong of a grounding system is desirable but not ... ESD common ground or reference point when working on your body. Proper grounding of the computer is a difference in protective packages until they exceed the requirements noted here. 2. Protect...is required for operator safety and correct system function. Handling electrostatic discharge-sensitive devices Any computer part containing transistors or integrated circuits (ICs) should be verified by equalizing the charge...
...a charge even when you use coax or connector-outside shells on ac-operated computers. Use the round ground-prong of a grounding system is desirable but not ... ESD common ground or reference point when working on your body. Proper grounding of the computer is a difference in protective packages until they exceed the requirements noted here. 2. Protect...is required for operator safety and correct system function. Handling electrostatic discharge-sensitive devices Any computer part containing transistors or integrated circuits (ICs) should be verified by equalizing the charge...
Hardware Maintenance Manual
Page 262
Laser compliance statement Some IBM Personal Computer models are also sold separately as options. When a CD-ROM drive is a laser product. The CD-ROM drive is certified to conform to the requirements ...) 825 and CENELEC EN 60 825 for Class 1 laser products. L'utilizzo di controlli, regolazioni o l'esecuzione di procedure diverse da quelle specificate possono provocare l'esposizione a 254 Netfinity Server HMM Elsewhere, the drive is certified in hazardous radiation exposure. Pour éviter tout risque d'exposition au rayon laser, respectez les consignes de ré...
Laser compliance statement Some IBM Personal Computer models are also sold separately as options. When a CD-ROM drive is a laser product. The CD-ROM drive is certified to conform to the requirements ...) 825 and CENELEC EN 60 825 for Class 1 laser products. L'utilizzo di controlli, regolazioni o l'esecuzione di procedure diverse da quelle specificate possono provocare l'esposizione a 254 Netfinity Server HMM Elsewhere, the drive is certified in hazardous radiation exposure. Pour éviter tout risque d'exposition au rayon laser, respectez les consignes de ré...
Hardware Maintenance Manual
Page 266
... Education Business Unit Customized Operational Services EduQuest (Educational Computers) End User HelpDesk Support IBM Anti-Virus Services IBM Authorized Dealer Referrals IBM Dealer Referral IBM Information Referral Service IBM Service IBM PC HelpCenter and HelpDesk IBM Technical Manuals Multimedia Information Center Multimedia HelpCenter OS/2 Information Line OS/2 Support Services Prodigy Prodigy User Questions Technical Coordinator Program SystemXtra for...
... Education Business Unit Customized Operational Services EduQuest (Educational Computers) End User HelpDesk Support IBM Anti-Virus Services IBM Authorized Dealer Referrals IBM Dealer Referral IBM Information Referral Service IBM Service IBM PC HelpCenter and HelpDesk IBM Technical Manuals Multimedia Information Center Multimedia HelpCenter OS/2 Information Line OS/2 Support Services Prodigy Prodigy User Questions Technical Coordinator Program SystemXtra for...