Owner's Manual
Page 2
This thermostat works with virtually all System Types - Call 1-800-468-1502 for the most common system We are here to help. Installation is preset for wiring assistance before returning the thermostat to match your heating/cooling system - It is Easy Label wires and remove your old thermostat Install and wire your new thermostat Set your new thermostat to the store. 69-2206EF-01 ii
This thermostat works with virtually all System Types - Call 1-800-468-1502 for the most common system We are here to help. Installation is preset for wiring assistance before returning the thermostat to match your heating/cooling system - It is Easy Label wires and remove your old thermostat Install and wire your new thermostat Set your new thermostat to the store. 69-2206EF-01 ii
Owner's Manual
Page 4
Old thermostat Cover 69-2206EF-01 M28099 2 Remove Old Thermostat Remove old thermostat but leave wallplate with wires attached. Leave wallplate in place Is there a sealed tube containing mercury? If so, see back cover for proper disposal instructions.
Old thermostat Cover 69-2206EF-01 M28099 2 Remove Old Thermostat Remove old thermostat but leave wallplate with wires attached. Leave wallplate in place Is there a sealed tube containing mercury? If so, see back cover for proper disposal instructions.
Owner's Manual
Page 5
Wire Labels M28100 M28093 69-2206EF-01 3 Label Wires with Tags Label the wires using the supplied wire labels as you disconnect them.
Wire Labels M28100 M28093 69-2206EF-01 3 Label Wires with Tags Label the wires using the supplied wire labels as you disconnect them.
Owner's Manual
Page 8
See page 21. Have a Heat Pump system? 6 Connect Wires Simply match wire labels. Labels don't match? See pages 22-23. Call 1-800-468-1502 for wiring assistance. 69-2206EF-01 We are here to help. CONVENTIONAL SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES CONVENTIONAL WIRE HOLE C W2 WY G G Y2 Y W RC R R M28070 Remove metal jumper if you have both R and Rc wires.
See page 21. Have a Heat Pump system? 6 Connect Wires Simply match wire labels. Labels don't match? See pages 22-23. Call 1-800-468-1502 for wiring assistance. 69-2206EF-01 We are here to help. CONVENTIONAL SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES CONVENTIONAL WIRE HOLE C W2 WY G G Y2 Y W RC R R M28070 Remove metal jumper if you have both R and Rc wires.
Owner's Manual
Page 14
Advanced Installation System setup 13 Wiring 21 Troubleshooting 24 Customer assistance 26 Limited warranty 27
Advanced Installation System setup 13 Wiring 21 Troubleshooting 24 Customer assistance 26 Limited warranty 27
Owner's Manual
Page 15
RTH7600 0120 20 System & Fan Schedule Clock & More M27522 Step 2 Press and hold the center key until the screen changes (approximately 5 seconds). 0120 20 System Fan Done M27523 ASSISTANCE TROUBLESHOOTING 13 69-2206EF-01 SETUP WIRING ASybsotuetmyosuertunpew thermostat Step 1 Press System & Fan.
RTH7600 0120 20 System & Fan Schedule Clock & More M27522 Step 2 Press and hold the center key until the screen changes (approximately 5 seconds). 0120 20 System Fan Done M27523 ASSISTANCE TROUBLESHOOTING 13 69-2206EF-01 SETUP WIRING ASybsotuetmyosuertunpew thermostat Step 1 Press System & Fan.
Owner's Manual
Page 16
Press DONE to previous selections made. NOTE: Some functions in the following pages may not appear due to save & exit. Press s t to change setting. SETUP WIRING Advanced Installation Guide ACbhoauntgiynogursentetwingthsermostat See pages 15-20 to change Function Settings. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 14 Function Setting 0120 20 Go Back Next Done M27524 Press NEXT to advance to next function.
Press DONE to previous selections made. NOTE: Some functions in the following pages may not appear due to save & exit. Press s t to change setting. SETUP WIRING Advanced Installation Guide ACbhoauntgiynogursentetwingthsermostat See pages 15-20 to change Function Settings. ASSISTANCE TROUBLESHOOTING 69-2206EF-01 14 Function Setting 0120 20 Go Back Next Done M27524 Press NEXT to advance to next function.
Owner's Manual
Page 17
... change the last two digits of the year: 01 - 99 (i.e., 2001 - 2099) 0140 Month Setting Press s/t to change the current month: 01 - 12 (i.e., January - SETUP WIRING RTH7600 ASybsotuetmyosuertunpew thermostat NOTE: If you set the time and date as shown on page 10, press NEXT to function 0170 and go to navigate...
... change the last two digits of the year: 01 - 99 (i.e., 2001 - 2099) 0140 Month Setting Press s/t to change the current month: 01 - 12 (i.e., January - SETUP WIRING RTH7600 ASybsotuetmyosuertunpew thermostat NOTE: If you set the time and date as shown on page 10, press NEXT to function 0170 and go to navigate...
Owner's Manual
Page 18
.... 4 Heat only with fan: Gas, oil or electric heat without central air condi- ASSISTANCE TROUBLESHOOTING 69-2206EF-01 16 SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to select your system Type type: 1 Heat/cool: Gas, oil or electric heating.... 8 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2 cooling stages (wires on Y and Y2). 9 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1 cooling stage (wire on Y). 10 Heat/Cool Multiple stages: 1 heat stage (wire on Y and Y2). tioning only. 7 Heat pump...
.... 4 Heat only with fan: Gas, oil or electric heat without central air condi- ASSISTANCE TROUBLESHOOTING 69-2206EF-01 16 SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to select your system Type type: 1 Heat/cool: Gas, oil or electric heating.... 8 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2 cooling stages (wires on Y and Y2). 9 Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1 cooling stage (wire on Y). 10 Heat/Cool Multiple stages: 1 heat stage (wire on Y and Y2). tioning only. 7 Heat pump...
Owner's Manual
Page 19
... Valve (for heat or cooling: pumps only) 0 Cooling changeover valve: Use this setting if you connected a wire labeled "O" to the O/B terminal (see page 22). 1 Heating changeover valve: Use this setting if you connected a wire labeled "B" to navigate between functions. SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to the O/B terminal (see page 23).
... Valve (for heat or cooling: pumps only) 0 Cooling changeover valve: Use this setting if you connected a wire labeled "O" to the O/B terminal (see page 22). 1 Heating changeover valve: Use this setting if you connected a wire labeled "B" to navigate between functions. SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to the O/B terminal (see page 23).
Owner's Manual
Page 20
SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to select your heating system: 9 Electric furnace: Electric heating systems. 5 Gas or oil furnace: Standard gas/oil ...
SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to select your heating system: 9 Electric furnace: Electric heating systems. 5 Gas or oil furnace: Standard gas/oil ...
Owner's Manual
Page 21
...). 1 Automatic changeover (Heat/ Cool/Auto/Off). Note: System maintains minimum 3°F difference between functions. Automatically turns on Heat or Cool based on room temperature. SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to navigate between heat and cool settings. 0320 Temperature Press s/t to set the temperature Format (°F/°C) display format...
...). 1 Automatic changeover (Heat/ Cool/Auto/Off). Note: System maintains minimum 3°F difference between functions. Automatically turns on Heat or Cool based on room temperature. SETUP WIRING ASybsotuetmyosuertunpew thermostat RTH7600 See page 14 to navigate between heat and cool settings. 0320 Temperature Press s/t to set the temperature Format (°F/°C) display format...
Owner's Manual
Page 22
SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to save and exit setup. Function Settings & Options 0500 Furnace Filter Press s/t to set the desired Change ...
SETUP WIRING Advanced Installation Guide ASybsotuetmyosuertunpew thermostat See page 14 to save and exit setup. Function Settings & Options 0500 Furnace Filter Press s/t to set the desired Change ...
Owner's Manual
Page 23
... the C terminal. If your old thermostat had 2 C or C1 wires, wrap each separately with electrical tape and do not match terminals, connect wires as shown here (see notes, below). SETUP AWbiroiuntg-yocuornnveewnttiohnearml soyssttaetm RTH7600 Alternate wiring (conventional systems) If labels do not connect them. WIRING ASSISTANCE TROUBLESHOOTING RC Rc 2 R R 2 W W Y Y G G C C 3 Y2 Y2 W2 W2 M28076...
... the C terminal. If your old thermostat had 2 C or C1 wires, wrap each separately with electrical tape and do not match terminals, connect wires as shown here (see notes, below). SETUP AWbiroiuntg-yocuornnveewnttiohnearml soyssttaetm RTH7600 Alternate wiring (conventional systems) If labels do not connect them. WIRING ASSISTANCE TROUBLESHOOTING RC Rc 2 R R 2 W W Y Y G G C C 3 Y2 Y2 W2 W2 M28076...
Owner's Manual
Page 24
... on thermostat, see page 23. Labels don't match? Use a screwdriver to each have a wire connected, use a small piece of wire to connect them to loosen screws, insert wires into the wall opening. SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES HEAT PUMP WIRE HOLE HEAT PUMP C Aux Aux OYG G E Y L O/B RC R R M28104 ASSISTANCE TROUBLESHOOTING 69-2206EF-01...
... on thermostat, see page 23. Labels don't match? Use a screwdriver to each have a wire connected, use a small piece of wire to connect them to loosen screws, insert wires into the wall opening. SCREW INSERT WIRES THEN TIGHTEN SCREWS LABELED WIRES HEAT PUMP WIRE HOLE HEAT PUMP C Aux Aux OYG G E Y L O/B RC R R M28104 ASSISTANCE TROUBLESHOOTING 69-2206EF-01...
Owner's Manual
Page 25
... there is attached to each other. 2 3 ASSISTANCE TROUBLESHOOTING 35 5 6 46 M28077 23 69-2206EF-01 If E and Aux terminals do not each have a wire 6 connected, use a small piece of wire to connect them to the C terminal, stop now and contact a qualified contractor for help . If your old thermostat had both V and VR...
... there is attached to each other. 2 3 ASSISTANCE TROUBLESHOOTING 35 5 6 46 M28077 23 69-2206EF-01 If E and Aux terminals do not each have a wire 6 connected, use a small piece of wire to connect them to the C terminal, stop now and contact a qualified contractor for help . If your old thermostat had both V and VR...
Owner's Manual
Page 26
... make sure it is set to match heat is set to match your heating equipment (see page 17). ASSISTANCE TROUBLESHOOTING 69-2206EF-01 24 SETUP WIRING Advanced Installation Guide Troubleshooting If you have difficulty with your heating and cooling equipment (see page 16). If thermostat is in Emergency Heat mode, contact...
... make sure it is set to match heat is set to match your heating equipment (see page 17). ASSISTANCE TROUBLESHOOTING 69-2206EF-01 24 SETUP WIRING Advanced Installation Guide Troubleshooting If you have difficulty with your heating and cooling equipment (see page 16). If thermostat is in Emergency Heat mode, contact...
Owner's Manual
Page 27
SETUP WIRING Troubleshooting RTH7600 Heating or cool- Make sure the temperature is heat mode, or properly configured for your system warm air in Changeover Valve to respond. ...