Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 3
......19 Expanding an array ...20 Migrating RAID level or stripe size ...20 HP Array Configuration Utility ...22 About ACU...22 Accessing ACU in the offline environment...22 Launching ACU with HP Intelligent Provisioning (Gen8 or later 22 Launching ACU during POST (Gen8 or later 23 Launching ACU from the SmartStart CD (G7 or earlier 23...
......19 Expanding an array ...20 Migrating RAID level or stripe size ...20 HP Array Configuration Utility ...22 About ACU...22 Accessing ACU in the offline environment...22 Launching ACU with HP Intelligent Provisioning (Gen8 or later 22 Launching ACU during POST (Gen8 or later 23 Launching ACU from the SmartStart CD (G7 or earlier 23...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 22
..., and ACU Scripting. Some of multiple methods, you must launch ACU from an ISO image. Starting with HP Intelligent Provisioning (Gen8 or later) 1. It exists in an offline environment. You can configure or maintain detected and supported ProLiant devices, such as setting the boot controller and boot volume. • Accessing ACU in the online...
..., and ACU Scripting. Some of multiple methods, you must launch ACU from an ISO image. Starting with HP Intelligent Provisioning (Gen8 or later) 1. It exists in an offline environment. You can configure or maintain detected and supported ProLiant devices, such as setting the boot controller and boot volume. • Accessing ACU in the online...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 23
...card (on page 24) • Installing the image on a PXE server (on page 25) Booting from an ISO image. Launching ACU during POST (Gen8 or later) 1. The system launches the ACU GUI. ACU opens, scans the local server, and detects controllers. Mounting the image on the Controller/Device...iLO (on page 24) • Burning the image to a CD or DVD (on page 24) • Flashing the image to 2 minutes. Download the HP ProLiant Offline Array Configuration Utility ISO image from the CD, and then loads the SmartStart executable and drivers. 4. Boot the server. The server boots from the...
...card (on page 24) • Installing the image on a PXE server (on page 25) Booting from an ISO image. Launching ACU during POST (Gen8 or later) 1. The system launches the ACU GUI. ACU opens, scans the local server, and detects controllers. Mounting the image on the Controller/Device...iLO (on page 24) • Burning the image to a CD or DVD (on page 24) • Flashing the image to 2 minutes. Download the HP ProLiant Offline Array Configuration Utility ISO image from the CD, and then loads the SmartStart executable and drivers. 4. Boot the server. The server boots from the...
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 63
When moving the logical drive, you can specify every physical drive in the command as an example. Syntax: modify [drives Command examples: HP Array Configuration Utility 63 1+0 (default value) Now, create the new array: => ctrl ch="Lab 4" create type=ld drives=1:13,1:14 size=300 raid=1+0 It is not strictly ....4 GB, OK) array B physicaldrive 1:13 (box 1:bay13, Parallel SCSI, 9.1 GB, OK) physicaldrive 1:14 (box 1:bay14, Parallel SCSI, 9.1 GB, OK) To create a second logical drive on Gen8 Smart Array controllers with SAAP enabled.
When moving the logical drive, you can specify every physical drive in the command as an example. Syntax: modify [drives Command examples: HP Array Configuration Utility 63 1+0 (default value) Now, create the new array: => ctrl ch="Lab 4" create type=ld drives=1:13,1:14 size=300 raid=1+0 It is not strictly ....4 GB, OK) array B physicaldrive 1:13 (box 1:bay13, Parallel SCSI, 9.1 GB, OK) physicaldrive 1:14 (box 1:bay14, Parallel SCSI, 9.1 GB, OK) To create a second logical drive on Gen8 Smart Array controllers with SAAP enabled.
Configuring Arrays on HP Smart Array Controllers Reference Guide
Page 86
When ACU Scripting captures a configuration, it reports volume sizes rounded down to each physical drive. However, if the size does not fit the geometry of all the strips across all ... factor. StripeSize Beginning with smaller controller cache sizes. (The controller must be rounded down to set an exact size without rounding. StripSize Beginning with Gen8 controllers) HP Array Configuration Utility 86 Strip sizes available for this option to read an entire stripe of data that is reduced for StripSize (on the controller and...
When ACU Scripting captures a configuration, it reports volume sizes rounded down to each physical drive. However, if the size does not fit the geometry of all the strips across all ... factor. StripeSize Beginning with smaller controller cache sizes. (The controller must be rounded down to set an exact size without rounding. StripSize Beginning with Gen8 controllers) HP Array Configuration Utility 86 Strip sizes available for this option to read an entire stripe of data that is reduced for StripSize (on the controller and...
HP ProLiant DL380p Gen8 Server User Guide
Page 48
...level as shown in this Gen8 server supports DDR3-1333 RDIMM up to having two single-rank DIMMs on these classifications. HP SmartMemory HP SmartMemory, introduced for spare replacement. HP SmartMemory 1.35V DDR3-1333 Registered memory is performance-tuned for HP ProLiant and BladeSystem servers and provides...enables Lockstep and Online Spare Memory modes. Letters identify the population order. Single-, dual-, and quad-rank DIMMs To understand and configure memory protection modes properly, an understanding of the slot numbers, see "DIMM slot locations (on the same module. A single-rank...
...level as shown in this Gen8 server supports DDR3-1333 RDIMM up to having two single-rank DIMMs on these classifications. HP SmartMemory HP SmartMemory, introduced for spare replacement. HP SmartMemory 1.35V DDR3-1333 Registered memory is performance-tuned for HP ProLiant and BladeSystem servers and provides...enables Lockstep and Online Spare Memory modes. Letters identify the population order. Single-, dual-, and quad-rank DIMMs To understand and configure memory protection modes properly, an understanding of the slot numbers, see "DIMM slot locations (on the same module. A single-rank...
HP ProLiant DL380p Gen8 Server User Guide
Page 92
... Maintenance features. • Intelligent Provisioning provides installation help for various server components. For specific OS support, see the HP website (http://www.hp.com/go /ilo). SPP is available in HP ProLiant Gen8 servers that you can download from HP iLO or HP Intelligent Provisioning and sent to deploy HP ProLiant server configurations. • Intelligent Provisioning assists with 1-minute granularity.
... Maintenance features. • Intelligent Provisioning provides installation help for various server components. For specific OS support, see the HP website (http://www.hp.com/go /ilo). SPP is available in HP ProLiant Gen8 servers that you can download from HP iLO or HP Intelligent Provisioning and sent to deploy HP ProLiant server configurations. • Intelligent Provisioning assists with 1-minute granularity.
HP ProLiant DL380p Gen8 Server User Guide
Page 98
... during boot. • If an optional controller is now available as an embedded utility, starting with HP ProLiant Gen8 servers. To configure arrays, see the HP ROM-Based Setup Utility User Guide on the HP website (http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c01608507/c01608507.pdf). For more than one or more information regarding the...
... during boot. • If an optional controller is now available as an embedded utility, starting with HP ProLiant Gen8 servers. To configure arrays, see the HP ROM-Based Setup Utility User Guide on the HP website (http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c01608507/c01608507.pdf). For more than one or more information regarding the...
Innovative technologies in HP ProLiant Gen8 servers
Page 6
...load conditions to maximize datacenter utilization. Power efficiency For ProLiant Gen8 servers, we developed HP Common Slot Platinum Plus and 750 W Common Slot -48VDC Power Supplies. CS Platinum Plus Power Supplies also support HP Power Discovery Services (Intelligent Power Discovery technology) to... PLUS specifications for multiple equipment configurations so you can use more servers, power supply harmonic currents can potentially limit the maximum attainable utilization. In addition, our engineers increased power factor at http://h20000.www2.hp.com/bc/docs/support/SupportManual/...
...load conditions to maximize datacenter utilization. Power efficiency For ProLiant Gen8 servers, we developed HP Common Slot Platinum Plus and 750 W Common Slot -48VDC Power Supplies. CS Platinum Plus Power Supplies also support HP Power Discovery Services (Intelligent Power Discovery technology) to... PLUS specifications for multiple equipment configurations so you can use more servers, power supply harmonic currents can potentially limit the maximum attainable utilization. In addition, our engineers increased power factor at http://h20000.www2.hp.com/bc/docs/support/SupportManual/...
Innovative technologies in HP ProLiant Gen8 servers
Page 9
...Configuration Utility (ACU) ACU-CLI (command line interface) SNMP agents Web-Based Enterprise Management (WBEM) providers The B-Series controllers (B320i and B120i) use an embedded RAID-on most Smart Array Controllers. The B320i controller supports up to remove the wrong drive. HP SmartDrive For our ProLiant Gen8... servers, we designed the HP SmartDrive for IT personnel. The copy operation reduces the time before an actual drive failure occurs. ...
...Configuration Utility (ACU) ACU-CLI (command line interface) SNMP agents Web-Based Enterprise Management (WBEM) providers The B-Series controllers (B320i and B120i) use an embedded RAID-on most Smart Array Controllers. The B320i controller supports up to remove the wrong drive. HP SmartDrive For our ProLiant Gen8... servers, we designed the HP SmartDrive for IT personnel. The copy operation reduces the time before an actual drive failure occurs. ...
Innovative technologies in HP ProLiant Gen8 servers
Page 11
...-of-the box, single-server deployment and configuration without the complexity of collectively. If some time passes before they occur. HP Active Health System The HP Active Health System is no longer need system and firmware CDs. All the up to the server. This makes deploying ProLiant Gen8 servers up -to-date tools, drivers, and...
...-of-the box, single-server deployment and configuration without the complexity of collectively. If some time passes before they occur. HP Active Health System The HP Active Health System is no longer need system and firmware CDs. All the up to the server. This makes deploying ProLiant Gen8 servers up -to-date tools, drivers, and...
Innovative technologies in HP ProLiant Gen8 servers
Page 12
...data center infrastructure management (DCIM) tools, such as SNMP alerts to help you could import only initial configurations. 12 On ProLiant Gen 8 servers running HP SIM 7.0, users can assign the software and firmware versions that waste data center resources. The software column ... power consumption by email. We let you import physical and power topology configuration updates into Insight Control power management from other management consoles. Health monitoring and alerting On ProLiant Gen8 servers, HP SIM will detect core error conditions within the server and report those error...
...data center infrastructure management (DCIM) tools, such as SNMP alerts to help you could import only initial configurations. 12 On ProLiant Gen 8 servers running HP SIM 7.0, users can assign the software and firmware versions that waste data center resources. The software column ... power consumption by email. We let you import physical and power topology configuration updates into Insight Control power management from other management consoles. Health monitoring and alerting On ProLiant Gen8 servers, HP SIM will detect core error conditions within the server and report those error...