HP Insight Server Migration Software for ProLiant User Guide
Page 6
... machine following SMP migration...135 Yellow bang (!) appears on the NIC adapter in Device Manager on the migrated virtual machine......135 Uninstallation......X2P migration of Windows 2000 to a server with the Emulex LPe1105-HP 4Gb FC HBA might not detect virtual machines on mapped network drives...the SMP boot CD on a manual boot 129 Migration process...129 Drivers cannot be installed or injected onto boot disk 129 Large volumes ... Components do not work after migrating a Hyper-V virtual machine to a ProLiant server........134 Static IP address cannot be resized from a Windows 2008 application...
... machine following SMP migration...135 Yellow bang (!) appears on the NIC adapter in Device Manager on the migrated virtual machine......135 Uninstallation......X2P migration of Windows 2000 to a server with the Emulex LPe1105-HP 4Gb FC HBA might not detect virtual machines on mapped network drives...the SMP boot CD on a manual boot 129 Migration process...129 Drivers cannot be installed or injected onto boot disk 129 Large volumes ... Components do not work after migrating a Hyper-V virtual machine to a ProLiant server........134 Static IP address cannot be resized from a Windows 2008 application...
HP Insight Server Migration Software for ProLiant User Guide
Page 18
...installing operating systems, to be performed. Resize is maintained in the ProLiant Essentials Foundation Pack, the SmartStart CD works with all ProLiant DL and ML 300, 500, and 700 series, and all drivers (including NIC drivers) on the destination server. Linux Support Pack IMPORTANT: The information ...in this section applies only to large volumes. HP SmartStart CD Provides step-by SMP. ...
...installing operating systems, to be performed. Resize is maintained in the ProLiant Essentials Foundation Pack, the SmartStart CD works with all ProLiant DL and ML 300, 500, and 700 series, and all drivers (including NIC drivers) on the destination server. Linux Support Pack IMPORTANT: The information ...in this section applies only to large volumes. HP SmartStart CD Provides step-by SMP. ...
HP Insight Server Migration Software for ProLiant User Guide
Page 55
... Size-This column displays the minimum size that a partition or disk can be configured. For information on -For each destination NIC as needed , do not enter any IP address addresses. 12. If PSP executables are available. Physical-to the Next wizard... page. • Disk 0, Disk 1, Disk2, and so on how to upload PSP executables, see the Upload Drivers section. • Select a PSP to for each row, the value in the Minimum Destination Size and Destination Size columns... value of Unallocated should be zero or a positive number to proceed to -ProLiant (P2P) migrations for the disk. 11.
... Size-This column displays the minimum size that a partition or disk can be configured. For information on -For each destination NIC as needed , do not enter any IP address addresses. 12. If PSP executables are available. Physical-to the Next wizard... page. • Disk 0, Disk 1, Disk2, and so on how to upload PSP executables, see the Upload Drivers section. • Select a PSP to for each row, the value in the Minimum Destination Size and Destination Size columns... value of Unallocated should be zero or a positive number to proceed to -ProLiant (P2P) migrations for the disk. 11.
HP Insight Server Migration Software for ProLiant User Guide
Page 57
... section in with sufficient RAM. Wait until all required drivers are migrated to the destination server as adding the /... /noexecute=optout /fastdetect multi(0)disk(0)rdisk(0)partition(1)\WINDOWS="HP SMP Preserved: Windows Server 2003, Enterprise" /userva=3030 /3gb /...NIC teaming is located on the destination server after migration by the guest operating system, and then reboot when prompted. Therefore, if dynamic disks are static, reassign them. 8. (Optional) Reassign drive letters to former dynamic disk partitions. 9. (Optional) Convert basic disks to -ProLiant...
... section in with sufficient RAM. Wait until all required drivers are migrated to the destination server as adding the /... /noexecute=optout /fastdetect multi(0)disk(0)rdisk(0)partition(1)\WINDOWS="HP SMP Preserved: Windows Server 2003, Enterprise" /userva=3030 /3gb /...NIC teaming is located on the destination server after migration by the guest operating system, and then reboot when prompted. Therefore, if dynamic disks are static, reassign them. 8. (Optional) Reassign drive letters to former dynamic disk partitions. 9. (Optional) Convert basic disks to -ProLiant...
HP Insight Server Migration Software for ProLiant User Guide
Page 101
For information on how to upload PSP executables, see the Upload Drivers section. • Select a PSP to install on the destination can be configured. • If the destination server is selected to reboot upon completion, additional ...options are available on the application station and selected, the network settings on the destination server and configure a static IP for each destination NIC as needed. 13. Review and confirm the migration details, and then click Begin Migration. Virtual-to-ProLiant (V2P) migrations 101 If PSP executables are available. Click Next. 14.
For information on how to upload PSP executables, see the Upload Drivers section. • Select a PSP to install on the destination can be configured. • If the destination server is selected to reboot upon completion, additional ...options are available on the application station and selected, the network settings on the destination server and configure a static IP for each destination NIC as needed. 13. Review and confirm the migration details, and then click Begin Migration. Virtual-to-ProLiant (V2P) migrations 101 If PSP executables are available. Click Next. 14.
HP Insight Server Migration Software for ProLiant User Guide
Page 102
...options menu, do not change the default selection, HP SIM WIN Conversion ProLiant Windows. 3. At each of the Welcome to continue the migration process, click Begin Migration again. 15. Check the network connections and reestablish NIC teaming, if necessary. 7. The active boot ...same time the current migration is complete, to perform additional migrations, click Begin New Migration. Install the latest HP ProLiant Support Pack, which includes ProLiant optimized drivers, utilities, and management agents. To install SNMP service, see your operating system documentation. 6. These options ...
...options menu, do not change the default selection, HP SIM WIN Conversion ProLiant Windows. 3. At each of the Welcome to continue the migration process, click Begin Migration again. 15. Check the network connections and reestablish NIC teaming, if necessary. 7. The active boot ...same time the current migration is complete, to perform additional migrations, click Begin New Migration. Install the latest HP ProLiant Support Pack, which includes ProLiant optimized drivers, utilities, and management agents. To install SNMP service, see your operating system documentation. 6. These options ...
HP Insight Server Migration Software for ProLiant User Guide
Page 134
...on the destination server after a migration. To resolve this issue: 1. Assign the driver letter in the migrated virtual machine guest using the disk administrator or manager. In ... Destination server mouse and keyboard do not work after migrating a Hyper-V virtual machine to a ProLiant server Before performing a migration, uninstall Hyper-V Integration Tools on the migrated operating system After a ... volumes do not appear in Windows Explorer. Reboot the destination server. Reconfigure the NIC connected to the network to the volume so it is installed automatically on the ...
...on the destination server after a migration. To resolve this issue: 1. Assign the driver letter in the migrated virtual machine guest using the disk administrator or manager. In ... Destination server mouse and keyboard do not work after migrating a Hyper-V virtual machine to a ProLiant server Before performing a migration, uninstall Hyper-V Integration Tools on the migrated operating system After a ... volumes do not appear in Windows Explorer. Reboot the destination server. Reconfigure the NIC connected to the network to the volume so it is installed automatically on the ...
HP Insight Server Migration Software for ProLiant User Guide
Page 135
... this issue: 1. After the installation is missing. From the application station, click Start→Programs→HP Insight Server Migration software for ProLiant→Uninstall HP Insight Server Migration software for it. When prompted to the SMP installation folder on the source server. Troubleshooting.../en-us. This might happen during V2V migrations between VMware Server and VMWare ESX servers. This detects the NIC adapter and configures the drivers for ProLiant. 3. To run the uninstallation process, double-click the unins000.exe file. To resolve this network adapter is...
... this issue: 1. After the installation is missing. From the application station, click Start→Programs→HP Insight Server Migration software for ProLiant→Uninstall HP Insight Server Migration software for it. When prompted to the SMP installation folder on the source server. Troubleshooting.../en-us. This might happen during V2V migrations between VMware Server and VMWare ESX servers. This detects the NIC adapter and configures the drivers for ProLiant. 3. To run the uninstallation process, double-click the unins000.exe file. To resolve this network adapter is...
HP Insight Server Migration Software for ProLiant User Guide
Page 146
...screen, 132 corrective action is required before migrating preinstalled operating systems, 123 corrective action is required for source servers with HP iLO Management Channel Interface Drivers, 123 Deploy Agent task fails, 124, 128 destination server displays blank screen when using SMP Boot CD, 126 ...131 V2V, 131 Yellow bang (!) appears on NIC adapter, 135 U uninstallation troubleshooting, 135 uninstalling older version of SMP application, 135 SMP application, 135 upgrading to SMP from SMP or P2P, 13 uploading drivers, 119 V V2P (see virtual-to-ProLiant) V2V (see virtual-to-virtual) verifying ...
...screen, 132 corrective action is required before migrating preinstalled operating systems, 123 corrective action is required for source servers with HP iLO Management Channel Interface Drivers, 123 Deploy Agent task fails, 124, 128 destination server displays blank screen when using SMP Boot CD, 126 ...131 V2V, 131 Yellow bang (!) appears on NIC adapter, 135 U uninstallation troubleshooting, 135 uninstalling older version of SMP application, 135 SMP application, 135 upgrading to SMP from SMP or P2P, 13 uploading drivers, 119 V V2P (see virtual-to-ProLiant) V2V (see virtual-to-virtual) verifying ...
HP Insight Management Agents architecture for Windows servers
Page 6
...) Interface information (Interface name, IPv4 address) Ethernet statistics NIC teaming configuration Source MIB-II, Windows OS, NIC miniport driver MIB-II, Windows OS NIC miniport driver, Windows OS Teaming intermediate driver 6 Table 4. NIC agent The NIC agent collects and stores information about the network controllers installed ...of information collected and displayed for SMI-S is collected through the Insight Management Agents. Multi-host storage on HP support for the network controllers. Additional information on the network, such as belonging to the single host server...
...) Interface information (Interface name, IPv4 address) Ethernet statistics NIC teaming configuration Source MIB-II, Windows OS, NIC miniport driver MIB-II, Windows OS NIC miniport driver, Windows OS Teaming intermediate driver 6 Table 4. NIC agent The NIC agent collects and stores information about the network controllers installed ...of information collected and displayed for SMI-S is collected through the Insight Management Agents. Multi-host storage on HP support for the network controllers. Additional information on the network, such as belonging to the single host server...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 1
...ProLiant server platforms 8 Supported components for ProLiant servers 10 Software drivers...10 Management software ...10 Storage options ...11 Tape options ...13 Network interface controllers ...14 IPMI and WS-Management ...15 IPMI and WS-Management for the HP ProLiant 100 Series servers 16 HP IPMI Provider for HP BladeSystem servers and ProLiant... 2008 upgrades 19 Upgrade policies ...20 Installing the ProLiant Support Pack ...20 Getting PSP updates ...20 NIC Teaming driver...20 Appendix A: known issues and workarounds 23 ProLiant servers with Windows Server 2008 23 Windows Server 2008...
...ProLiant server platforms 8 Supported components for ProLiant servers 10 Software drivers...10 Management software ...10 Storage options ...11 Tape options ...13 Network interface controllers ...14 IPMI and WS-Management ...15 IPMI and WS-Management for the HP ProLiant 100 Series servers 16 HP IPMI Provider for HP BladeSystem servers and ProLiant... 2008 upgrades 19 Upgrade policies ...20 Installing the ProLiant Support Pack ...20 Getting PSP updates ...20 NIC Teaming driver...20 Appendix A: known issues and workarounds 23 ProLiant servers with Windows Server 2008 23 Windows Server 2008...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 14
...digital signature. HP-branded drivers are only available on the software and drivers website: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. Supported ProLiant Gigabit Ethernet NICs Gigabit NIC Driver Location NC1020 NC150T... 9 9 Supported architecture x86 x64 9 9 99 9 9 9 9 14 Network interface controllers Table 5 lists supported ProLiant network interface controllers (NICs) supported by Windows Server 2008. However, corresponding NIC drivers from Intel and Broadcom are available on the Windows Server 2008 media may not be available on...
...digital signature. HP-branded drivers are only available on the software and drivers website: http://h20000.www2.hp.com/bizsupport/TechSupport/ProductRoot.jsp?lang=en&cc=us&taskId=135. Supported ProLiant Gigabit Ethernet NICs Gigabit NIC Driver Location NC1020 NC150T... 9 9 Supported architecture x86 x64 9 9 99 9 9 9 9 14 Network interface controllers Table 5 lists supported ProLiant network interface controllers (NICs) supported by Windows Server 2008. However, corresponding NIC drivers from Intel and Broadcom are available on the Windows Server 2008 media may not be available on...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 15
...• Intelligent Platform Management Interface (IPMI) - The driver will be added to computer hardware that implements a high-level abstraction of the PSP. Table 5. Supported ProLiant Gigabit Ethernet NICs Gigabit NIC NC360T NC360m NC364T NC364m NC370T/F/i NC371i NC373T/F/M/i NC374M NC380T... NC7761 NC7771 NC7782 PCI-X NC7781 Driver N1E5132.SYS N1E5132E.SYS BXVBDX.SYS BXVBDA.SYS Location PSP 8.00 ...
...• Intelligent Platform Management Interface (IPMI) - The driver will be added to computer hardware that implements a high-level abstraction of the PSP. Table 5. Supported ProLiant Gigabit Ethernet NICs Gigabit NIC NC360T NC360m NC364T NC364m NC370T/F/i NC371i NC373T/F/M/i NC374M NC380T... NC7761 NC7771 NC7782 PCI-X NC7781 Driver N1E5132.SYS N1E5132E.SYS BXVBDX.SYS BXVBDA.SYS Location PSP 8.00 ...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 20
...or higher; INP was also removed from the Windows Server 2003 teaming driver. 20 Installing the ProLiant Support Pack Getting PSP updates • PSP updates are available on the HP website: www.hp.com/go/ws2008 or the FTP site at either of Windows Server 2008... Multi-function offload properties exposed • Intel driver support • Broadcom Legacy support NOTES OEM drivers appear in the NIC Configuration Utility (NCU) but should not be teamed or configured in conjunction with the Windows Server 2008 NIC teaming driver. Refer to Windows Server 2008 Enterprise regular installation...
...or higher; INP was also removed from the Windows Server 2003 teaming driver. 20 Installing the ProLiant Support Pack Getting PSP updates • PSP updates are available on the HP website: www.hp.com/go/ws2008 or the FTP site at either of Windows Server 2008... Multi-function offload properties exposed • Intel driver support • Broadcom Legacy support NOTES OEM drivers appear in the NIC Configuration Utility (NCU) but should not be teamed or configured in conjunction with the Windows Server 2008 NIC teaming driver. Refer to Windows Server 2008 Enterprise regular installation...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 23
...HP Smart Array controller, these polices in the device manager for certain storage adapters or NICs. Issue 4 Storage drivers do not get loaded during installation of Windows Server 2008. Issue 5 On servers booting from Internal 4/8 Port SAS Controller, upgrading from the \windows\system32\drivers... may display upon installation of Windows Server 2008. Appendix A: known issues and workarounds ProLiant servers with Windows Server 2008 Table A-1 lists the known issues with ProLiant servers with Windows Server 2008. Use the Array Configuration Utility (ACU) to the minimum...
...HP Smart Array controller, these polices in the device manager for certain storage adapters or NICs. Issue 4 Storage drivers do not get loaded during installation of Windows Server 2008. Issue 5 On servers booting from Internal 4/8 Port SAS Controller, upgrading from the \windows\system32\drivers... may display upon installation of Windows Server 2008. Appendix A: known issues and workarounds ProLiant servers with Windows Server 2008 Table A-1 lists the known issues with ProLiant servers with Windows Server 2008. Use the Array Configuration Utility (ACU) to the minimum...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers
Page 24
...installing the PSP. Issue 2 HP StorageWorks Fibre Channel Array Notification Driver component shows update not required, if a supported MSA controller is targeted for a future release of the known issues with the PSP Issue Details Issue 1 The G5 NIC drivers are not found behind a ... 2008 media. already current" and the installation log states that "Not updated - Description The NIC driver for the CP6316 NIC fails to install. 24 Table A-2. Windows Server 2008 ProLiant Support Pack (PSP) Table A-2 provides a list of the PSP. Workaround Fixed in the Windows...
...installing the PSP. Issue 2 HP StorageWorks Fibre Channel Array Notification Driver component shows update not required, if a supported MSA controller is targeted for a future release of the known issues with the PSP Issue Details Issue 1 The G5 NIC drivers are not found behind a ... 2008 media. already current" and the installation log states that "Not updated - Description The NIC driver for the CP6316 NIC fails to install. 24 Table A-2. Windows Server 2008 ProLiant Support Pack (PSP) Table A-2 provides a list of the PSP. Workaround Fixed in the Windows...
HP ProLiant Servers Troubleshooting Guide
Page 188
...processors and speed o Number of DIMMs and their size and speed o List of controllers and NICs o List of connected peripheral devices o List of any other optional HP or Compaq hardware o Network configuration • Specific software information: o Operating system information ("Operating... system information you need" on page 188) o List of third-party, HP, and Compaq software installed o PCAnywhere information, if installed o Verification of latest drivers installed o Verification of latest ROM/BIOS o Verification of latest firmware on array controllers and drives...
...processors and speed o Number of DIMMs and their size and speed o List of controllers and NICs o List of connected peripheral devices o List of any other optional HP or Compaq hardware o Network configuration • Specific software information: o Operating system information ("Operating... system information you need" on page 188) o List of third-party, HP, and Compaq software installed o PCAnywhere information, if installed o Verification of latest drivers installed o Verification of latest ROM/BIOS o Verification of latest firmware on array controllers and drives...
HP ProLiant DL380p Gen8 Server User Guide
Page 127
... 19 hardware options installation 39, 42 health driver 103 health LEDs 9 help resources 122 hot-plug fans 21, 26 hot-plug SAS hard drive options 55 HP Insight Diagnostics 96 HP Insight Remote Support software 105 HP Smart Update Manager overview 93, 98 HP technical support 105, 122 I identification number ... memory, configuring 52, 53 memory, lockstep 53, 54 memory, mirrored 101 memory, online spare 53, 100 mirrored memory 101 52, 54 N NIC connectors 12 NMI jumper 17 O online spare memory 53, 100 operating system crash 17 operating systems 105 optical drive 7, 62 optical drive cable 87...
... 19 hardware options installation 39, 42 health driver 103 health LEDs 9 help resources 122 hot-plug fans 21, 26 hot-plug SAS hard drive options 55 HP Insight Diagnostics 96 HP Insight Remote Support software 105 HP Smart Update Manager overview 93, 98 HP technical support 105, 122 I identification number ... memory, configuring 52, 53 memory, lockstep 53, 54 memory, mirrored 101 memory, online spare 53, 100 mirrored memory 101 52, 54 N NIC connectors 12 NMI jumper 17 O online spare memory 53, 100 operating system crash 17 operating systems 105 optical drive 7, 62 optical drive cable 87...
Deploying and updating VMware vSphere 5.0 on HP ProLiant Servers Integration Note
Page 2
...drives provide drive health data for deploying and updating VMware vSphere 5.0 on ProLiant servers. The HP custom image available from the HP ESXi 5.0 product page at boot time, and includes the base image, additional drivers, HP components, and other third-party components. • VMware base image: The...card. You can use locally attached drives as data stores to take advantage of approved devices from the HP Online Depot includes the required NIC, iSCSI, FC, and FCoE drivers. After deploying the image, you choose to use the VMware base image with vSphere 5.0 to host virtual...
...drives provide drive health data for deploying and updating VMware vSphere 5.0 on ProLiant servers. The HP custom image available from the HP ESXi 5.0 product page at boot time, and includes the base image, additional drivers, HP components, and other third-party components. • VMware base image: The...card. You can use locally attached drives as data stores to take advantage of approved devices from the HP Online Depot includes the required NIC, iSCSI, FC, and FCoE drivers. After deploying the image, you choose to use the VMware base image with vSphere 5.0 to host virtual...
Deploying and updating VMware vSphere 5.0 on HP ProLiant Servers Integration Note
Page 7
... base image that require a custom image, see the HP ProLiant Server VMware Support Matrix at least one NIC device does not load • The inability to install ESXi to install ESXi if a NIC driver for at http://h18004.www1.hp.com/products/servers/vmware/supportmatrix/hpvmware.html. Type PowerCLI ...> $ip.VibList | more 16. Add the hp-smx-provider software package or VIB. This may take a few minutes....
... base image that require a custom image, see the HP ProLiant Server VMware Support Matrix at least one NIC device does not load • The inability to install ESXi to install ESXi if a NIC driver for at http://h18004.www1.hp.com/products/servers/vmware/supportmatrix/hpvmware.html. Type PowerCLI ...> $ip.VibList | more 16. Add the hp-smx-provider software package or VIB. This may take a few minutes....