HP P6300/P6500 EVA Installation Guide (5697-2485, September 2013)
Page 5
P6300 to P6350 or P6500 to P6550. • Determine if the FC host ports will be lossy or lossless and if iSCSI and/or FCoE are factory configured for fabric-attached. See the P6000 QuickSpecs for SFP transceiver and cable part numbers. To change to direct-attached mode, see... EVA Upgrade Instructions - Overview 5 The P63x0/P65x0 EVAs are being supported. NOTE: If also upgrading from P6300/P6500 to P6350/P6550, respectively, see HP P6000 Enterprise Virtual Array Compatibility Reference. • A CD/DVD drive attached to either the management server or the server attached to the ...
P6300 to P6350 or P6500 to P6550. • Determine if the FC host ports will be lossy or lossless and if iSCSI and/or FCoE are factory configured for fabric-attached. See the P6000 QuickSpecs for SFP transceiver and cable part numbers. To change to direct-attached mode, see... EVA Upgrade Instructions - Overview 5 The P63x0/P65x0 EVAs are being supported. NOTE: If also upgrading from P6300/P6500 to P6350/P6550, respectively, see HP P6000 Enterprise Virtual Array Compatibility Reference. • A CD/DVD drive attached to either the management server or the server attached to the ...
HP P6300/P6500 EVA Installation Guide (5697-2485, September 2013)
Page 11
... 3 P63x0/P65x0 FCoE management and data connectivity example NOTE: For the minimum supported configuration and other configuration information, see the QuickSpecs at least 6 of the possible 36 target WWNs, the target portal and two storage target ports for each iSCSI/FCoE module... example Figure 3 (page 11) illustrates a simplified multi-protocol data and management configuration. common management zone. Once this connectivity is established, HP P6000 Command View can be used to be managed. Proceed to initialize the storage system and then navigate to the Hardware > iSCSI Devices ...
... 3 P63x0/P65x0 FCoE management and data connectivity example NOTE: For the minimum supported configuration and other configuration information, see the QuickSpecs at least 6 of the possible 36 target WWNs, the target portal and two storage target ports for each iSCSI/FCoE module... example Figure 3 (page 11) illustrates a simplified multi-protocol data and management configuration. common management zone. Once this connectivity is established, HP P6000 Command View can be used to be managed. Proceed to initialize the storage system and then navigate to the Hardware > iSCSI Devices ...
HP P6300/P6500 EVA Installation Guide (5697-2485, September 2013)
Page 19
...and redundant sources of power Make sure that you have two high-line power feeds installed near your installation. Consider using the HP Enterprise Configurator (eCO) to provide adequate clearance around the front and back of the racks. For protection against a power-...source failure, obtain and include two uninterruptible power supplies in an approved environment. For power consumption specifications, see the QuickSpecs document at: http://www.hp.com/go/P6000 Remove product from different grids or even entirely different sources. Verify that contents match your expectations and ...
...and redundant sources of power Make sure that you have two high-line power feeds installed near your installation. Consider using the HP Enterprise Configurator (eCO) to provide adequate clearance around the front and back of the racks. For protection against a power-...source failure, obtain and include two uninterruptible power supplies in an approved environment. For power consumption specifications, see the QuickSpecs document at: http://www.hp.com/go/P6000 Remove product from different grids or even entirely different sources. Verify that contents match your expectations and ...
HP P6300/P6500 EVA User Guide (5697-2486, September 2013)
Page 31
...specifications about PDU support with the P63x0/P65x0 EVA, see the HP Power Distribution Units website: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/pdu.html The standard power configuration for any HP Enterprise Virtual Array rack is distributed to the right PDM in...index.html Power distribution units AC power is the fully redundant configuration. For information about specific PDU models, see the HP P6300/P6500 Enterprise Virtual Arrays QuickSpecs. All PDMs are located (side by side in a PDM pair with a compatible wall receptacle. • One ...
...specifications about PDU support with the P63x0/P65x0 EVA, see the HP Power Distribution Units website: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/pdu.html The standard power configuration for any HP Enterprise Virtual Array rack is distributed to the right PDM in...index.html Power distribution units AC power is the fully redundant configuration. For information about specific PDU models, see the HP P6300/P6500 Enterprise Virtual Arrays QuickSpecs. All PDMs are located (side by side in a PDM pair with a compatible wall receptacle. • One ...
HP P6300/P6500 EVA User Guide (5697-2486, September 2013)
Page 52
For more information, refer to the Enterprise Virtual Array QuickSpecs and associated release notes. HP-UX To create virtual disks for your configuration. Enter the command # ioscan ...the insf command: # insf -e NOTE: Lowercase e assigns device special files only to the new devices-in HP P6000 Command View. • Ensure that the host WWN number is set correctly (to the host you are...disk is presented to access the virtual disk: • Verify that the correct host is correct for HP-UX, scan the bus and then create volume groups on the storage system. 2. Creating and presenting virtual...
For more information, refer to the Enterprise Virtual Array QuickSpecs and associated release notes. HP-UX To create virtual disks for your configuration. Enter the command # ioscan ...the insf command: # insf -e NOTE: Lowercase e assigns device special files only to the new devices-in HP P6000 Command View. • Ensure that the host WWN number is set correctly (to the host you are...disk is presented to access the virtual disk: • Verify that the correct host is correct for HP-UX, scan the bus and then create volume groups on the storage system. 2. Creating and presenting virtual...
HP P6000 Enterprise Virtual Array Disk Drive Firmware Support (5697-2829)
Page 6
... but remain the latest and only recommended versions for use with EVA3000/5000. See the QuickSpecs on these array models for example, 200 2 TB drives or 400 1 TB drives). HP Command View EVA Version 9.4 is the only active version that supports the EVA3000/5000 family... limit per disk group is supported with XCS 10001000 or later. 6 Table 2 15K RPM Fibre Channel drives (continued) Type HP model displayed in HP EVA Recommended Supported controller software P6000 Command View firmware version version BF450DA483 HP09 6.2x0, 0953x000,2 10001000 or later BF450D6189 HP04 6.2x0...
... but remain the latest and only recommended versions for use with EVA3000/5000. See the QuickSpecs on these array models for example, 200 2 TB drives or 400 1 TB drives). HP Command View EVA Version 9.4 is the only active version that supports the EVA3000/5000 family... limit per disk group is supported with XCS 10001000 or later. 6 Table 2 15K RPM Fibre Channel drives (continued) Type HP model displayed in HP EVA Recommended Supported controller software P6000 Command View firmware version version BF450DA483 HP09 6.2x0, 0953x000,2 10001000 or later BF450D6189 HP04 6.2x0...