Service Manual
Page 3
1.Description of Air Conditioners Working temperature range Rated Maximum Cooling Indoor DB℃ 27 32 WB℃ 19 23 outdoor DB℃ 35 43 WB℃ 24 26 Heating ... mounted type, "F" stands for console type, "U" stands for outdoor of split unit Max. 1 to 3 1.2 Brief Introduction for T1,T2,T3 working condition Type of Conditioner Cooling Only Air T1 18 ℃~43℃ Heat pump -7℃~43℃ Electricity Heating ~43℃ Climate type T2 10℃~35℃ -7℃~35℃...
1.Description of Air Conditioners Working temperature range Rated Maximum Cooling Indoor DB℃ 27 32 WB℃ 19 23 outdoor DB℃ 35 43 WB℃ 24 26 Heating ... mounted type, "F" stands for console type, "U" stands for outdoor of split unit Max. 1 to 3 1.2 Brief Introduction for T1,T2,T3 working condition Type of Conditioner Cooling Only Air T1 18 ℃~43℃ Heat pump -7℃~43℃ Electricity Heating ~43℃ Climate type T2 10℃~35℃ -7℃~35℃...
Service Manual
Page 4
...designer and installer. As a result, the user will be controlled at 10℃. Adopt the much friendlier refrigerant R410a The air conditioner system adopts the greatly friendly refrigerant R410a, which belongs to save power energy is more smoothly. More choice, more conveniently. 10...multi upgrade series, unitary smart DC inverter and HAIER DAC split inverter type The indoor units are universal for the outdoors which is protective for the ozone layer and is no communication wire between indoors. Commercial Air Conditioner 1.4 Product features DC inverter technology, high energy...
...designer and installer. As a result, the user will be controlled at 10℃. Adopt the much friendlier refrigerant R410a The air conditioner system adopts the greatly friendly refrigerant R410a, which belongs to save power energy is more smoothly. More choice, more conveniently. 10...multi upgrade series, unitary smart DC inverter and HAIER DAC split inverter type The indoor units are universal for the outdoors which is protective for the ozone layer and is no communication wire between indoors. Commercial Air Conditioner 1.4 Product features DC inverter technology, high energy...
Service Manual
Page 5
... the failure code chart, you can eliminate the failure soon. Weekly timing function, if connected with a central controller That is convenient for building management. Commercial Air Conditioner on the operation panel. Central control function, if connected with a weekly timer Universal power supply for 50Hz and 60Hz The multi upgrade series adopts universal...
... the failure code chart, you can eliminate the failure soon. Weekly timing function, if connected with a central controller That is convenient for building management. Commercial Air Conditioner on the operation panel. Central control function, if connected with a weekly timer Universal power supply for 50Hz and 60Hz The multi upgrade series adopts universal...
Service Manual
Page 6
...the combination of rows Face area mm TP2M / 7.94 2 m² about 2000 Heat exchanger Type / Diameter Number of 3U19FS1ERA+3*AS09CS1ERA 2. It is a sound pressure noise level. 2. Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB...24℃WB, outdoor temperature(heating): 7 ℃DB/6℃WB The noise level will obviously reduce the total capacity. Specifications Commercial Air Conditioner Item Model 3U19FS1ERA Function Cooling Heating Rating capacity W 5400 6500 Power input (indoor + outdoor) W 1410 1520 Current input (indoor + outdoor) A...
...the combination of rows Face area mm TP2M / 7.94 2 m² about 2000 Heat exchanger Type / Diameter Number of 3U19FS1ERA+3*AS09CS1ERA 2. It is a sound pressure noise level. 2. Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB...24℃WB, outdoor temperature(heating): 7 ℃DB/6℃WB The noise level will obviously reduce the total capacity. Specifications Commercial Air Conditioner Item Model 3U19FS1ERA Function Cooling Heating Rating capacity W 5400 6500 Power input (indoor + outdoor) W 1410 1520 Current input (indoor + outdoor) A...
Service Manual
Page 47
...circuit , and wiring by the manufacturer or its previous state. Incorrect wiring will damage the controller of indoor unit. Communication wire of air conditioner or the unit can not operate. 3. Wiring method Wiring method of orbicular terminals For the connection wire with orbicular terminals, its wiring... cover. The grounding wire and the neutral wire shall be fastened by consumers themselves. -46- Electric wiring The air conditioner must be strictly separated. Wiring method of outdoor unit: Power line Remove the repair board of power line is incorrect.
...circuit , and wiring by the manufacturer or its previous state. Incorrect wiring will damage the controller of indoor unit. Communication wire of air conditioner or the unit can not operate. 3. Wiring method Wiring method of orbicular terminals For the connection wire with orbicular terminals, its wiring... cover. The grounding wire and the neutral wire shall be fastened by consumers themselves. -46- Electric wiring The air conditioner must be strictly separated. Wiring method of outdoor unit: Power line Remove the repair board of power line is incorrect.
Service Manual
Page 63
...on the top or rear.) Fig. 31 Cover plate (Right) (2) When the voltage is too low and the air conditioner is difficult to the capacity of the room air conditioner. (3) The circuit breaker is insufficient, change the contracted capacity. 1.Mount the cover plate. (Right) (1) Cut a... any gas leakage? ELECTRICAL WIRING WARNING (1) Always use a special branch circuit and install a special receptacle to supply power to the room air conditioner. (2) Use a circuit breaker and receptacle matched to start, contact the power company the voltage raised. When the current contracted capacity is ...
...on the top or rear.) Fig. 31 Cover plate (Right) (2) When the voltage is too low and the air conditioner is difficult to the capacity of the room air conditioner. (3) The circuit breaker is insufficient, change the contracted capacity. 1.Mount the cover plate. (Right) (1) Cut a... any gas leakage? ELECTRICAL WIRING WARNING (1) Always use a special branch circuit and install a special receptacle to supply power to the room air conditioner. (2) Use a circuit breaker and receptacle matched to start, contact the power company the voltage raised. When the current contracted capacity is ...
Service Manual
Page 67
..., using middle static terminal (terminal color is red), the distance between air duct outlet and air conditioner outlet is white), the distance between air duct outlet and air conditioner outlet could be also connected to the air supply inlet. Adjust the wind speed of each air diffuser outlet to keep in the room. See Fig.1. Figure 5 sling dog...
..., using middle static terminal (terminal color is red), the distance between air duct outlet and air conditioner outlet is white), the distance between air duct outlet and air conditioner outlet could be also connected to the air supply inlet. Adjust the wind speed of each air diffuser outlet to keep in the room. See Fig.1. Figure 5 sling dog...
Service Manual
Page 68
...height exceeds 0.9 m, M10 size is needed for air supply and return duct. These screws shall be supported by the beams and then set with space adapting to air conditioner overall dimensions according to the air return shutter. Air duct insulation Insulation layer is the only choice). ...Finally, seal the air duct interface with tinfoil adhesive tape closely. Wooden structure A square ...
...height exceeds 0.9 m, M10 size is needed for air supply and return duct. These screws shall be supported by the beams and then set with space adapting to air conditioner overall dimensions according to the air return shutter. Air duct insulation Insulation layer is the only choice). ...Finally, seal the air duct interface with tinfoil adhesive tape closely. Wooden structure A square ...
Service Manual
Page 133
...the wind screen. 6.Press "ON/OFF"switch, off . Remarks Avoid pressing "ON/OFF" switch frequently. Press "ON/OFF" switch. 5 The air conditioner starts operating, and the light on the wired controller is on the line controller to change . and clock zone "8888"-"888"-"88""8" flicker for ...will display,and set temperature will change to "AUTO"--"HIGH"--"MED"--"LOW"--"AUTO" 5.Press "swing" switch on the basis of the outer air conditioner and system protection. All the switches are invalid at the time. The temperature is on line controller directly The line controller displays the ...
...the wind screen. 6.Press "ON/OFF"switch, off . Remarks Avoid pressing "ON/OFF" switch frequently. Press "ON/OFF" switch. 5 The air conditioner starts operating, and the light on the wired controller is on the line controller to change . and clock zone "8888"-"888"-"88""8" flicker for ...will display,and set temperature will change to "AUTO"--"HIGH"--"MED"--"LOW"--"AUTO" 5.Press "swing" switch on the basis of the outer air conditioner and system protection. All the switches are invalid at the time. The temperature is on line controller directly The line controller displays the ...