Haier AU60NFIERA Support and Manuals

Get Help and Manuals for this Haier item

View All Support Options Below
Free Haier AU60NFIERA manuals!
Problems with Haier AU60NFIERA?

Ask a Question

Most Recent Haier AU60NFIERA Questions

The Indoor Unit Pcv District Setting For 1 Hp To 2 Hp
I want to know how to give the district setting of AU60NFIERA on the indoor unit PCV district to mak...
(Posted by mgmhtet8816 5 years ago)

Popular Haier AU60NFIERA Manual Pages

Installation Instructions - Page 6

4. Refrigerant circuit AU282FHERA Ta one-way valve Tc strainer PMV strainer Te accumulator liquid pipe strainer SV2 outdoor 4-way valve gas pipe strainer oil segregator OP strainer oil return capillary Ts Td compressor LP gas-liquid segregator 图例 connected disconnected Tc2 PMV Ta indoor Tc1 06
Installation Instructions - Page 7

AU48NFIERA AU60NFIERA Ta 室外 HEX one-way valve Te Tc strainer PMV strainer accumulator strainer SV2 liquid pipe 4-way valve gas pipe strainer SV1 strainer oil segregator strainer OP oil return capillary Td Ts compressor LP gas-liquid segregator legend outdoor connected disconnected PMV Tc2 Ta Tc1 indoor 07
Installation Instructions - Page 25

....1 4.77 14.5 4.86 14.8 4.92 15.3 5.02 16.0 5.17 16.6 5.26 17.7 5.41 18.8 5.56 19.4 5.66 20.0 5.71 20.6 5.80 21.4 5.85 22.0 5.90 AU60NFIERA heating mode indoor temp.℃DB 18.0 20.0 21.0 TC PI TC PI TC PI KW KW KW KW KW KW 12.7 4.02 12.7 4.24...
Installation Instructions - Page 43

.9/ Gnlltmhb`shnm vhqd enq vhqdc bnmsqnkkdq vhqd kdmfsg.l/ vhqd rodb vhqd kdmfsg.l/ vhqd rodb 7766 :766 `mc 4866 :866 `mc 4966 649ll8 9.93bnqd/ rghdkcdc vhqd 64;ll8 9 .93bnqd/ rghdkcdc vhqd 64=;ll8 9 .93bnqd/ rghdkcdc vhqd ~066 `mc B166 ~166 `mc B366 748;ll8 9.93bnqd/ rghdkcdc vhqd 8ll8 9 .93bnqd/ rghdkcdc vhqd `4 Wghdkcdc k`xdq ne bnlltmhb`shnm vhqd ltrs ad d`qsgdc `s nmd dmc4 a4 Xgd sns...
Installation Instructions - Page 63

... signal interference? no Check outdoor mainboard. Make necessary replacement 63 Troubleshooting: 1.Communication failure Is number of indoor and outdoor units no Use shielded wire. yes Is indoor unit address properly set separately? Shield layer should be grounded at single point Are communication wire and power cable set ? yes Is shielded wire used for communication...
Installation Instructions - Page 64

... Replace sensor 3.EEPROM failure no Re-wire as the wiring diagram Replace the power module 64 Over current protection Check if the compressor current yes Check the system, fan motor, is broken? no Check the wiring condition yes no EEPROM chip installed firmly Reinstall in right direction yes Is the PCB poorly w elded...
Installation Instructions - Page 65

... balance pressure and running pressure to see if the refrigerant is high, if SV2 by thermometer too high? yes cleaning no yes Adjustment or replacement When TD is too much or lack. yes Conduct...EEV work normally no Replace TD sensor sensor in system? Evacuate and recharge no Check fan motor and capacitor yes Is filter or heat exchanger dirty? yes no Repair outdoor EEV Is actual ...
Installation Instructions - Page 66

... piping twisted or deformed? no no Replace high pressure switch pressure gauge above 3MPa? Is there air in good condition? and if indoor fan motor and indoor EEV work properly during heating cycle? Is reading of outdoor unit open? yes Are stop valve yes Repair or replacement if outdoor fan motor work properly during...
Installation Instructions - Page 67

... low protection Are connectors of refrigerant? no Replace low pressure switch yes If outdoor stop valves of gas pipe no Repair fan motor and EEV yes If the filter and heat exchanger are open totally Open stop valve yes Is piping twisted or deformed? 7 . no Adjust and maintain no Replace PCB Is pressure valve...
Installation Instructions - Page 68

...control wire is correct 10.Failure code from 24 to 27, from 30 to 40 Re-electrified, check if the failure disappears no Replace power module 11. Failure code 28 and 29: Check if...Suction temperature protection Measure if the actual air return temperature is over 40degree yes no Check if the wiring between them is normal yes Check if the sequence of refrigerant; if the system is normal; if...

Haier AU60NFIERA Reviews

Do you have an experience with the Haier AU60NFIERA that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Haier yet.

Popular Haier AU60NFIERA Search Terms

The following terms are frequently used to search for Haier AU60NFIERA support:

Ask a New Question
Use the box below to post a new question about Haier AU60NFIERA.
Manuals / Documents
Download any of our Haier AU60NFIERA manuals for free!

We have the following 1 documents available for the Haier AU60NFIERA:
  • Installation Instructions

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier AU60NFIERA manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier AU60NFIERA user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.