Commercial Air Conditioning SERVICE MANUAL MULTI upgrade series Models Indoor: AB09CS1ERA AB12CS1ERA AB18CS1ERA AB24ES1ERA AC12CS1ERA AC18CS1ERA AC24CS1ERA AD09LS1ERA AD12LS1ERA AD18LS1ERA AD24LS1ERA Outdoor: 3U19FS1ERA 4U25HS1ERA 4U30HS1ERA 5U34HS1ERA z DC inverter technology, high energy efficiency, higher EER A+, energy saving for the user z Universal indoor units for multi upgrade series, ...
Service Manual - Page 3

...Air Conditioners Working temperature range Rated Maximum Cooling Indoor DB℃ 27 32 WB℃ 19 23 outdoor DB℃ 35 43 WB℃ 24 26 Heating Indoor DB℃ 20 27 WB℃ 14.5 -- Products code...type, refrigerant is R22 B stands for heat pump type, refrigerant is R407C E stands for heat pump type, refrigerant is R410A N stands for cool only type, refrigerant is ...
Service Manual - Page 4

... and HAIER DAC split inverter type The indoor units are universal for the outdoors which will control refrigerant flow more precisely. Benefit for designer and installer. Multiple control types The indoor unit can match with multiple indoor units, up to EASY STOCK series. Auto-restart function (optional) All indoor units have already installed the air conditioner...
Service Manual - Page 5

... building management. Central control function, if connected with a weekly timer Universal power supply for 50Hz and 60Hz The multi upgrade series adopts universal power supply for 50Hz and 60Hz, which is convenient for design. Commercial Air Conditioner on the operation panel. Then according to the failure code chart, you can eliminate the failure soon.
Service Manual - Page 6

... piping installation will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. Specifications Commercial Air Conditioner Item Model 3U19FS1ERA Function Cooling... dB(A) kg / kg 35 52/-/63/-/51/ 53 Type / Charge kg R410A /1.9 Refrigerant No need to recharge total liquid piping length m 30 Recharge g/m 20 Piping Pipe size...
Service Manual - Page 10

...Model AB09CS1ERA Function cooling heating Capacity kW 2.6 2.9 Sensible heat ratio 0.71 / Dehumidifying capacity 10‐³×m³/h 1.5 Power Supply 1PH,220-230V 50-60HZ Type × Number CENTRIFUGALX1 Fan Speed(H-M-L) Fan motor output power r/min kW 690/620/560 0.03 Air.../ Shipping) kg / kg 2.8 / 4.8 Refrigerant Type R410A Pipe Liquid Gas mm φ6.35...
Service Manual - Page 11

... Model Function Capacity kW Sensible heat ratio Dehumidifying capacity 10‐³×m³/h Power Supply Type × Number Fan Speed(H-M-L) Fan motor output power r/min kW Air-flow...20/18 wired Fresh air hole dimension Electricity Heater Noise level ---sound presure (H-M-L) Noise level ---sound power (H-M-L) Weight (Net / Shipping) Refrigerant Type Pipe Liquid Gas...
Service Manual - Page 47

... its repair center or other similar qualified person.The connecting cable must be strictly separated. Electric wiring The air conditioner must be... grounding wire is incorrect. The electric leakage breaker must be replaced by wire cover. The wiring method of straight terminals. Slightly... to confirm it must be installed. Wiring method Wiring method of orbicular terminals For the connection...
Service Manual - Page 49

...installed in the system) after the unit starts, the CN4 ON SW1 1234 CN1 Errors...is 230V. To test heating,set the lowest temperature at 30 OC..., refer to operate through the instruction manual. Seven-segment numeric display 1) ...code. Please kindly explain to our customers how to the service manual. Wiring Error Check This product is capable of automatic checking of refrigerant...
Service Manual - Page 63

... and install a special receptacle to supply power to the room air conditioner. (2) Use a circuit breaker and receptacle matched to the capacity of the room air conditioner. (3) The circuit breaker is installed in accordance with the operating manual: (1) Starting and stopping method, operation switching, temperature adjustment, timer, air flow switching, and other electrical appliances.
Service Manual - Page 67

... Unit M8 broad lock ring M8 nut Installation for air duct of air diffuser air diffuser Fig1: Duct connected -66- See Fig.1. >_]]VbTZR\ _^UZdZ_^Vb The distance between air duct outlet and air conditioner outlet is according to the length of actually installed air duct and in service behavior of the static pressure terminal: Installation sketch map for long and short...
Service Manual - Page 68

... return connected 3. as follows with space adapting to air conditioner overall dimensions according to the air return inlet of the indoor unit. Knife embedded part Guide plate embedded part Iron reinforcement Foundation bolt Pipe suspension foundation bolt -67- These screws shall be supported by the beams and then set with tinfoil adhesive tape closely. Square wood Suspension...
Service Manual - Page 77

...4 OFF OFF ON ON --------- 5678 definition cooling only heat pump (default) set ON if frost easily set dip switch Small service PCB:0151800076 SW1 definition: 1 OFF ON OFF OFF OFF ON 2 OFF OFF...73 74 1111 76 77 78 79 Note: "0" means the dip switch is "ON" SW7: pre-set OFF if hard to frost(default) Max. OFF --- running current is 11A normal control (default) OFF ...
Service Manual - Page 132

...SET RECOVERY CHECK FILTER RESET ON/OFF Time switch It is off function. SYS. The mode is as follows: No display-air change (automatic)air change (RECOVERY)-air... speed Swing switch Open and close air change switch It is on and ...switch It is used for changing set temperature MODE AUTO FAN ONLY ...NO. Clock, timing and address setting Air change function. C ROOM TEMP. The...
Service Manual - Page 133

... "8888"-"888"-"88""8" flicker for two seconds. Remarks Avoid pressing "ON/OFF" switch frequently. Note Several seconds after the operation of the line controller, the setting of the outer air conditioner and system protection. The wind temperature may not be displayed). 1. MODE FAN SWING HEALTH TEMP CLOCK TIME TIMER...

Haier 3U19FS1ERA Reviews

Do you have an experience with the Haier 3U19FS1ERA that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Haier yet.

Popular Haier 3U19FS1ERA Search Terms

The following terms are frequently used to search for Haier 3U19FS1ERA support:

Ask a New Question
Use the box below to post a new question about Haier 3U19FS1ERA.
Manuals / Documents
Download any of our Haier 3U19FS1ERA manuals for free!

We have the following 1 documents available for the Haier 3U19FS1ERA:
  • Service Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Haier Manuals

Find free Haier 3U19FS1ERA manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Haier Reviews

View thousands of Haier 3U19FS1ERA user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Haier customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Haier customer service rankings, employee comments and much more from our sister site.

Haier Recalls

Find comprehensive Haier recall information updated hourly on RecallOwl.com.