Use and Care Manual
Page 1
As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR® ...;aise For a French version of this manual, visit our Website at GEAppliances.com. Write the model and serial numbers here: Model Serial Find these numbers on a label on the front of the base pan behind the front...Filter 11 Front Grille 10 Grille and Case 10 Outdoor Coils 10 Installation Instructions Before You Begin 12, 13 Installing a J-Model in an Existing Wall Case 14 Through-the-Wall Installation 15 Window Installation (Optional 16-21 Troubleshooting Tips 22 Normal Operating...
As an ENERGY STAR® partner, GE has determined that this product meets the ENERGY STAR® ...;aise For a French version of this manual, visit our Website at GEAppliances.com. Write the model and serial numbers here: Model Serial Find these numbers on a label on the front of the base pan behind the front...Filter 11 Front Grille 10 Grille and Case 10 Outdoor Coils 10 Installation Instructions Before You Begin 12, 13 Installing a J-Model in an Existing Wall Case 14 Through-the-Wall Installation 15 Window Installation (Optional 16-21 Troubleshooting Tips 22 Normal Operating...
Use and Care Manual
Page 3
... Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com USE OF EXTENSION CORDS-115-Volt models only WARNING! USE OF ADAPTER PLUGS-115-Volt models only WARNING! Can cause injury or death. ■ We strongly recommend against the use of an adapter plug...conditioner until a proper ground has been established. ■ Attaching the adapter ground terminal to break with any of the 230/208-volt models. ■ If you must be aligned with the larger slot in the connection of the cord be made to a properly grounded 2-...
... Operating Instructions Care and Cleaning Installation Instructions Troubleshooting Tips Consumer Support GEAppliances.com USE OF EXTENSION CORDS-115-Volt models only WARNING! USE OF ADAPTER PLUGS-115-Volt models only WARNING! Can cause injury or death. ■ We strongly recommend against the use of an adapter plug...conditioner until a proper ground has been established. ■ Attaching the adapter ground terminal to break with any of the 230/208-volt models. ■ If you must be aligned with the larger slot in the connection of the cord be made to a properly grounded 2-...
Use and Care Manual
Page 4
... controls on the air conditioner control panel indicate the selected settings. Air Conditioner Controls Lights beside the touch pads on the air conditioner-Cool Only Models Appearance may vary.
... controls on the air conditioner control panel indicate the selected settings. Air Conditioner Controls Lights beside the touch pads on the air conditioner-Cool Only Models Appearance may vary.
Use and Care Manual
Page 6
Air Conditioner Controls Lights beside the touch pads on the air conditioner-Heat/Cool Models Appearance may vary. Indicator lights on the air conditioner controls will show the mode selected. TEMP Increase + /Decrease - Each touch will set the time in ...
Air Conditioner Controls Lights beside the touch pads on the air conditioner-Heat/Cool Models Appearance may vary. Indicator lights on the air conditioner controls will show the mode selected. TEMP Increase + /Decrease - Each touch will set the time in ...
Use and Care Manual
Page 8
... continuously. The owner is down (continuous). The default setting is responsible for future use) Fan Cycle/Continuous - Remote Thermostat (on some models) When this switch is enabled (UP), it allows the indoor fan to operate with the compressor. Remove the front grille. 2. Fan ...Cycle/Continuous - The default setting is enabled (UP), it allows the indoor fan to run continuously with the heater operation. Heat (on some models) Class 2 (on /off with a Class 2 Remote Control Wall Thermostat. Fan Cycle/Continuous - When CLOSED, only the air inside air discharge...
... continuously. The owner is down (continuous). The default setting is responsible for future use) Fan Cycle/Continuous - Remote Thermostat (on some models) When this switch is enabled (UP), it allows the indoor fan to operate with the compressor. Remove the front grille. 2. Fan ...Cycle/Continuous - The default setting is enabled (UP), it allows the indoor fan to run continuously with the heater operation. Heat (on some models) Class 2 (on /off with a Class 2 Remote Control Wall Thermostat. Fan Cycle/Continuous - When CLOSED, only the air inside air discharge...
Use and Care Manual
Page 9
... and tighten screws securely. 4 After all desired connections have been made to any circuit. Special care must be controlled by a remote thermostat. Class 2 (on some models) The controls are located under front grille 9 When connected, the unit will be in connecting the wires. NOTE: The number 3 dip switch must be made...
... and tighten screws securely. 4 After all desired connections have been made to any circuit. Special care must be controlled by a remote thermostat. Class 2 (on some models) The controls are located under front grille 9 When connected, the unit will be in connecting the wires. NOTE: The number 3 dip switch must be made...
Use and Care Manual
Page 10
... case. Front Grille The front grille can be professionally steam cleaned, a service available through your GE service outlet. Grille Tab 10 Outdoor Coils The coils on the top of the base pan.... from the wall outlet before cleaning. Pull the filter out. 2. Grille Tab On some models On some models To replace: Hook the tabs on the front grille even with dirt or soot they may... be removed for more thorough cleaning and to locate the model and serial numbers on the case and snap into place. To remove: 1. Replace the screws and...
... case. Front Grille The front grille can be professionally steam cleaned, a service available through your GE service outlet. Grille Tab 10 Outdoor Coils The coils on the top of the base pan.... from the wall outlet before cleaning. Pull the filter out. 2. Grille Tab On some models On some models To replace: Hook the tabs on the front grille even with dirt or soot they may... be removed for more thorough cleaning and to locate the model and serial numbers on the case and snap into place. To remove: 1. Replace the screws and...
Use and Care Manual
Page 11
...Replacement filters are installed correctly. 3 Reattach the cover by pushing it back into place. Air Filter To remove the air filter, on some models: Carefully pull the tab forward, up and out. A clogged filter reduces cooling, heating and air flow. To replace the air filter: Replace...days. Do not use rechargeable batteries. ■ Remove the batteries from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers. To remove the air filter, on other models: FRONT FRONT Pull it should be used for a long time. 11 Turn the ...
...Replacement filters are installed correctly. 3 Reattach the cover by pushing it back into place. Air Filter To remove the air filter, on some models: Carefully pull the tab forward, up and out. A clogged filter reduces cooling, heating and air flow. To replace the air filter: Replace...days. Do not use rechargeable batteries. ■ Remove the batteries from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers. To remove the air filter, on other models: FRONT FRONT Pull it should be used for a long time. 11 Turn the ...
Use and Care Manual
Page 12
...circuit breaker. Answer these instructions completely and carefully. • IMPORTANT - What is the model number of the GE warranty. D What type of the wall case currently in use ? Risk of a new GE Wall Case. Where a 2-prong wall outlet is encountered, it replaced with a properly grounded...an architectural grille attached to a wall case to ensure proper airflow. 12 GE strongly recommends the removal of the old wall case and the installation of electric shock. J-MODEL QUALIFYING QUESTIONS J-model air conditioners may fit in use ? B What are the dimensions of outdoor...
...circuit breaker. Answer these instructions completely and carefully. • IMPORTANT - What is the model number of the GE warranty. D What type of the wall case currently in use ? Risk of a new GE Wall Case. Where a 2-prong wall outlet is encountered, it replaced with a properly grounded...an architectural grille attached to a wall case to ensure proper airflow. 12 GE strongly recommends the removal of the old wall case and the installation of electric shock. J-MODEL QUALIFYING QUESTIONS J-model air conditioners may fit in use ? B What are the dimensions of outdoor...
Use and Care Manual
Page 13
Installation Instructions Read these kits for all other brands not listed All GE Models GE RAB13, 14 & 15 (ACLB & RCL Chassis) Hotpoint ACXB10 & 11 (ACTB Chassis) Whirlpool Type 23W Wall Case GE RAB30 ("F" models) Fedders Wall Case "A" RAK126 Westinghouse Wall Case (Type 2626D73H01) RAB46, 47 & 48 Use these ... device. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use this kit to a "J" model chassis. Fits all GE models and other brands not listed. Fits Whirlpool wall cases 257⁄ 8″W x 161⁄ 2″H x 231⁄ 8″D....
Installation Instructions Read these kits for all other brands not listed All GE Models GE RAB13, 14 & 15 (ACLB & RCL Chassis) Hotpoint ACXB10 & 11 (ACTB Chassis) Whirlpool Type 23W Wall Case GE RAB30 ("F" models) Fedders Wall Case "A" RAK126 Westinghouse Wall Case (Type 2626D73H01) RAB46, 47 & 48 Use these ... device. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use this kit to a "J" model chassis. Fits all GE models and other brands not listed. Fits Whirlpool wall cases 257⁄ 8″W x 161⁄ 2″H x 231⁄ 8″D....
Use and Care Manual
Page 14
Installation Instructions INSTALLING A J-MODEL IN AN EXISTING WALL CASE Read these instructions completely and carefully. 1 REMOVE LOCKING PLATE ON FRONT LEFT SIDE Locking plate Remove screw 4 REINSTALL LOCKING PLATE ...
Installation Instructions INSTALLING A J-MODEL IN AN EXISTING WALL CASE Read these instructions completely and carefully. 1 REMOVE LOCKING PLATE ON FRONT LEFT SIDE Locking plate Remove screw 4 REINSTALL LOCKING PLATE ...
Use and Care Manual
Page 15
... wall. The cord length for improved caulking. Flashing - Inside Top of wall to be undercut at about 45° for the 115-volt models is available close to the hole location or make arrangements to install a receptacle. extension inside of the building. extension out from dripping inside wall... or with 1/4″ min. extension out from the trim molding 15 For the 230/208-volt models the cord length is 65″ to the right and 39″ to the left. 2 SUPPORT REQUIREMENTS FOR AIR CONDITIONER The air conditioner ...
... wall. The cord length for improved caulking. Flashing - Inside Top of wall to be undercut at about 45° for the 115-volt models is available close to the hole location or make arrangements to install a receptacle. extension inside of the building. extension out from dripping inside wall... or with 1/4″ min. extension out from the trim molding 15 For the 230/208-volt models the cord length is 65″ to the right and 39″ to the left. 2 SUPPORT REQUIREMENTS FOR AIR CONDITIONER The air conditioner ...
Use and Care Manual
Page 22
Problem Air conditioner does not start Air conditioner does not cool or heat (some models), press the DECREASE - Power failure. Airflow is escaping. Cold air is restricted. The batteries are no curtains, blinds or furniture blocking the front of the ... the air conditioner from the case front to melt. • Check the position of the air conditioner. • In COOL mode or HEAT mode (some models) as it should be inserted correctly. • Replace the batteries. • This is normal for service.
Problem Air conditioner does not start Air conditioner does not cool or heat (some models), press the DECREASE - Power failure. Airflow is escaping. Cold air is restricted. The batteries are no curtains, blinds or furniture blocking the front of the ... the air conditioner from the case front to melt. • Check the position of the air conditioner. • In COOL mode or HEAT mode (some models) as it should be inserted correctly. • Replace the batteries. • This is normal for service.
Use and Care Manual
Page 23
...after delivery. ■ Product not accessible to a defect in Canada, contact Gordon Williams Corp. If you may also have serial number and model number available when calling for a particular purpose, are , consult your local or state consumer affairs office or your dealer or installer. Some states... or consequential damages. EXCLUSION OF IMPLIED WARRANTIES-Your sole and exclusive remedy is located in this four-year limited additional warranty, GE will also provide, free of merchantability or fitness for service. If the product is product repair as provided in an area ...
...after delivery. ■ Product not accessible to a defect in Canada, contact Gordon Williams Corp. If you may also have serial number and model number available when calling for a particular purpose, are , consult your local or state consumer affairs office or your dealer or installer. Some states... or consequential damages. EXCLUSION OF IMPLIED WARRANTIES-Your sole and exclusive remedy is located in this four-year limited additional warranty, GE will also provide, free of merchantability or fitness for service. If the product is product repair as provided in an area ...
Quick Specs
Page 1
...calculated by Underwriters Laboratories 390256 Premium, Deluxe and Value Model Wall Case Dimensions (in inches) 15-5/8 For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. 16-7/8... air flow areas. Specification Created 9/09 Listed by the Association of Home Appliance Manufacturers' standards. Do not restrict air flow areas. AJCQ10DCD GE® ENERGY STAR® 230/208 Volt Built-in Room Air Conditioner Wall Case Dimensions and Installation Information (in inches) Note:...
...calculated by Underwriters Laboratories 390256 Premium, Deluxe and Value Model Wall Case Dimensions (in inches) 15-5/8 For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. 16-7/8... air flow areas. Specification Created 9/09 Listed by the Association of Home Appliance Manufacturers' standards. Do not restrict air flow areas. AJCQ10DCD GE® ENERGY STAR® 230/208 Volt Built-in Room Air Conditioner Wall Case Dimensions and Installation Information (in inches) Note:...
Quick Specs
Page 3
AJCQ10DCD GE® ENERGY STAR® 230/208 Volt Built-in Room Air Conditioner Features and Benefits • R-410A Refrigerant • 10,400/10,200 Cooling BTU • 9.4/9.4 EER • 230/208 Volts • Energy Star® qualified • Electronic controls with remote • Electronic digital thermostat • Four-way air direction • Up-front, washable air filter • 3 cool/3 fan speeds • Unit dimensions: 14-7/8"W x 24-3/4"H x 19-7/8"D • Model AJCQ10DCD - Soft Gray AJCQ12DCD Specification Created 9/09 390256
AJCQ10DCD GE® ENERGY STAR® 230/208 Volt Built-in Room Air Conditioner Features and Benefits • R-410A Refrigerant • 10,400/10,200 Cooling BTU • 9.4/9.4 EER • 230/208 Volts • Energy Star® qualified • Electronic controls with remote • Electronic digital thermostat • Four-way air direction • Up-front, washable air filter • 3 cool/3 fan speeds • Unit dimensions: 14-7/8"W x 24-3/4"H x 19-7/8"D • Model AJCQ10DCD - Soft Gray AJCQ12DCD Specification Created 9/09 390256