Owner's Manual
Page 16
...a frequency on one page, that setting is a vertical flasher along a scale. Select MENU > Setup > Sonar Setup > Fish Symbols. 2. echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual When using a dual-beam transducer, you configure the appearance of suspended targets on one page, that are ... pages. 1. A-Scope The A-Scope is applied to see . The 200 kHz frequency shows better detail, has a narrower beam, and is typically used to see more fish. When you can be used in detecting fish that setting is easier to cover a larger area. Select a frequency....
...a frequency on one page, that setting is a vertical flasher along a scale. Select MENU > Setup > Sonar Setup > Fish Symbols. 2. echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual When using a dual-beam transducer, you configure the appearance of suspended targets on one page, that are ... pages. 1. A-Scope The A-Scope is applied to see . The 200 kHz frequency shows better detail, has a narrower beam, and is typically used to see more fish. When you can be used in detecting fish that setting is easier to cover a larger area. Select a frequency....
Owner's Manual
Page 17
... of the alarm setting. 4. echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual Using the echo 2. The alarm setting appears. 4. Select an option: • Select to sound an alarm for all fish sizes. • Select to sound an alarm for large fish only. Select an option: ...when the device is turned off . 1. From any page, select MENU > Setup > Alarms. 2. From any page, select MENU > Setup > Alarms > Fish. 2. Select Done or Confirm. 13 The alarm setting appears. 4. Turning On the A-Scope From the Full Screen page (page 4), select MENU > Setup > ...
... of the alarm setting. 4. echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual Using the echo 2. The alarm setting appears. 4. Select an option: • Select to sound an alarm for all fish sizes. • Select to sound an alarm for large fish only. Select an option: ...when the device is turned off . 1. From any page, select MENU > Setup > Alarms. 2. From any page, select MENU > Setup > Alarms > Fish. 2. Select Done or Confirm. 13 The alarm setting appears. 4. Turning On the A-Scope From the Full Screen page (page 4), select MENU > Setup > ...
Owner's Manual
Page 22
... a mild detergent solution. 2. Select the language. 18 echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual Shallow and deep water performance is used with the echo device, it can damage plastic components. 1. Wipe the device dry. However, when this transducer is maximized because the echo series shows more fish when shallow, and reaches deep to show...
... a mild detergent solution. 2. Select the language. 18 echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual Shallow and deep water performance is used with the echo device, it can damage plastic components. 1. Wipe the device dry. However, when this transducer is maximized because the echo series shows more fish when shallow, and reaches deep to show...
Owner's Manual
Page 24
Index Index A alarms battery voltage 13 beeper 2 drift 14 fish 13 shallow and deep water 13 temperature 13 A-Scope 12 B backlight 1 battery voltage alarm...alarm 13 depth line 11 depth log duration 6 scale 6 viewing 6, 7 depth scale 9 drift alarm 14 F factory settings, restoring 19 fish alarm 13 symbols 12 Flasher page 8 frequency selecting 12 split screen 5 Full Screen page 4 G gain setting automatically 14 setting manually 14... sensor, calibrating 17 speed, showing 15 Split Frequency page 5 split size 5 echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual
Index Index A alarms battery voltage 13 beeper 2 drift 14 fish 13 shallow and deep water 13 temperature 13 A-Scope 12 B backlight 1 battery voltage alarm...alarm 13 depth line 11 depth log duration 6 scale 6 viewing 6, 7 depth scale 9 drift alarm 14 F factory settings, restoring 19 fish alarm 13 symbols 12 Flasher page 8 frequency selecting 12 split screen 5 Full Screen page 4 G gain setting automatically 14 setting manually 14... sensor, calibrating 17 speed, showing 15 Split Frequency page 5 split size 5 echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual
Owner's Manual
Page 25
Index Split Zoom page 5 surface noise 15 symbols, fish 12 system information 19 T temperature alarm 13 temperature log duration 7 scale 7 viewing 7 temperature offset 17 temperature, showing 15 Z zoom adjusting automatically 10 adjusting manually 9 split screen 5 U units of measure 19 V version, software 19 voltage alarm 13 W water speed odometer, displaying 16 sensor, calibrating 17 showing 15 water temperature alarm 13 water temperature offset 17 water temperature, showing 15 echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual 21
Index Split Zoom page 5 surface noise 15 symbols, fish 12 system information 19 T temperature alarm 13 temperature log duration 7 scale 7 viewing 7 temperature offset 17 temperature, showing 15 Z zoom adjusting automatically 10 adjusting manually 9 split screen 5 U units of measure 19 V version, software 19 voltage alarm 13 W water speed odometer, displaying 16 sensor, calibrating 17 showing 15 water temperature alarm 13 water temperature offset 17 water temperature, showing 15 echo 200, echo 300c, echo 500c, and echo 550c Owner's Manual 21