Fluke ScopeMeter Product Datasheet
Page 3
... Case (C190 or C120) The SCC-kit can "freeze" the last 100 screens and scroll through picture-bypicture or replay as part of the Fluke ScopeMeter 190 series inputs can be ordered separately, or with your ScopeMeter by: • Documenting - All models also have three independently floating isolated inputs...and average over a long period of instrument and accessories. All inputs are instantly recognized and settings adjusted for further analysis. And the standard probes cover a wide application range from the speed and convenience when measuring a number of time.
... Case (C190 or C120) The SCC-kit can "freeze" the last 100 screens and scroll through picture-bypicture or replay as part of the Fluke ScopeMeter 190 series inputs can be ordered separately, or with your ScopeMeter by: • Documenting - All models also have three independently floating isolated inputs...and average over a long period of instrument and accessories. All inputs are instantly recognized and settings adjusted for further analysis. And the standard probes cover a wide application range from the speed and convenience when measuring a number of time.
Fluke ScopeMeter Product Datasheet
Page 4
.... (See technical specifications for details on the test tool in fault-finding, e.g. scope, resistance and continuity measurements • 10:1 Voltage Probe included with large non-linear loads. Meter mode You don't need of simultaneously measuring and checking waveforms. The unique Connect-and-View™...make measurements referenced to 1000 V CAT II are able to fit comfortably in your hand. The Fluke 125 validates the quality of 20 MHz (Fluke 123) or 40 MHz (Fluke 124, 125) the Fluke 120 Series will capture and display almost any signal. It helps you want to a halt. ...
.... (See technical specifications for details on the test tool in fault-finding, e.g. scope, resistance and continuity measurements • 10:1 Voltage Probe included with large non-linear loads. Meter mode You don't need of simultaneously measuring and checking waveforms. The unique Connect-and-View™...make measurements referenced to 1000 V CAT II are able to fit comfortably in your hand. The Fluke 125 validates the quality of 20 MHz (Fluke 123) or 40 MHz (Fluke 124, 125) the Fluke 120 Series will capture and display almost any signal. It helps you want to a halt. ...
Fluke ScopeMeter Product Datasheet
Page 5
...Probe (standard included with a complete accessory package including line voltage adapter and battery pack (installed). Fluke. to 100 V/div. 5 mV/div. ohms - Ordering information Fluke 199C Fluke 199C/S Fluke 196C Fluke 196C/S Fluke 199B Fluke 199B/S Fluke 196B Fluke 196B/S Fluke 192B Fluke 192B/S Fluke 125 Fluke 125/S Fluke 124 Fluke 124/S Fluke 123 Fluke 123... Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz...
...Probe (standard included with a complete accessory package including line voltage adapter and battery pack (installed). Fluke. to 100 V/div. 5 mV/div. ohms - Ordering information Fluke 199C Fluke 199C/S Fluke 196C Fluke 196C/S Fluke 199B Fluke 199B/S Fluke 196B Fluke 196B/S Fluke 192B Fluke 192B/S Fluke 125 Fluke 125/S Fluke 124 Fluke 124/S Fluke 123 Fluke 123... Warranty 190C ScopeMeter Series 190B ScopeMeter Series 120 Series Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B Fluke 125 Fluke 124 Fluke 123 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz...
Fluke 123 and 124 Scopemeter Datasheet
Page 1
... applications. Leave all covered by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. 40 MHz FLUKE-124/003S Industrial ScopeMeter 40 MHz with oscilloscope, multimeter and "paperless" recorder in the harshest industrial environments. Dual-input...probe included standard with Fluke 124 • Up to stop. The included accessories allow hook-up to 1000 V CAT II are truly integrated test tools, with SCC Kit For more information, go to a PC for once again a stable display. Ordering information FLUKE-123/003 Industrial ScopeMeter 20 MHz FLUKE-123...
... applications. Leave all covered by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. 40 MHz FLUKE-124/003S Industrial ScopeMeter 40 MHz with oscilloscope, multimeter and "paperless" recorder in the harshest industrial environments. Dual-input...probe included standard with Fluke 124 • Up to stop. The included accessories allow hook-up to 1000 V CAT II are truly integrated test tools, with SCC Kit For more information, go to a PC for once again a stable display. Ordering information FLUKE-123/003 Industrial ScopeMeter 20 MHz FLUKE-123...
FE 123 & 124 Users Manual
Page 6
Fluke 123/124 Users Manual Freezing the Screen...16 Holding a Stable Reading 16 Making Relative Measurements 17 Selecting Auto/Manual Ranges 18 Changing the Graphic Representation on ... TrendPlotting a Waveform 22 Acquiring the Waveform 23 Triggering on a Waveform 27 Saving and Recalling a Setup and a Screen 32 Making Cursor Measurements 35 Using the 10:1 Probe for High Frequency Measurements 38 Using a Printer ...39 Using FlukeView® Software 41 2 Maintaining the Test Tool 43 About this Chapter ...43 Cleaning the Test...
Fluke 123/124 Users Manual Freezing the Screen...16 Holding a Stable Reading 16 Making Relative Measurements 17 Selecting Auto/Manual Ranges 18 Changing the Graphic Representation on ... TrendPlotting a Waveform 22 Acquiring the Waveform 23 Triggering on a Waveform 27 Saving and Recalling a Setup and a Screen 32 Making Cursor Measurements 35 Using the 10:1 Probe for High Frequency Measurements 38 Using a Printer ...39 Using FlukeView® Software 41 2 Maintaining the Test Tool 43 About this Chapter ...43 Cleaning the Test...
FE 123 & 124 Users Manual
Page 10
Fluke 123/124 Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit. (see Figure 1.): # Description 1 Fluke Test Tool 2 Rechargeable Battery Pack 3 Power Adapter/Battery Charger 4 Shielded Test Leads with Black Ground Leads 5 Test Lead Black...14 Hard Carrying Case 15 10:1 Voltage Probe Note When new, the rechargeable battery pack is not fully charged. See Chapter 2. Fluke 123 Model 123 NiCd 1x Fluke 123/S Model 123 NiCd 2x) • • • • • Fluke 124 Model 124 NiMH 1x • Fluke 124/S Model 124 NiMH 2x) ...
Fluke 123/124 Users Manual Unpacking the Test Tool Kit The following items are included in your test tool kit. (see Figure 1.): # Description 1 Fluke Test Tool 2 Rechargeable Battery Pack 3 Power Adapter/Battery Charger 4 Shielded Test Leads with Black Ground Leads 5 Test Lead Black...14 Hard Carrying Case 15 10:1 Voltage Probe Note When new, the rechargeable battery pack is not fully charged. See Chapter 2. Fluke 123 Model 123 NiCd 1x Fluke 123/S Model 123 NiCd 2x) • • • • • Fluke 124 Model 124 NiMH 1x • Fluke 124/S Model 124 NiMH 2x) ...
FE 123 & 124 Users Manual
Page 13
... of more than 4800 VA: • Use only insulated voltage probes, test leads and adapters supplied with the Test Tool, or indicated as suitable for the Fluke 123/124 Test Tool. • Before use, inspect voltage probes, test leads and accessories for mechanical damage and replace when damaged.... • Remove all probes, test leads and accessories that are more commonly available you might...
... of more than 4800 VA: • Use only insulated voltage probes, test leads and adapters supplied with the Test Tool, or indicated as suitable for the Fluke 123/124 Test Tool. • Before use, inspect voltage probes, test leads and accessories for mechanical damage and replace when damaged.... • Remove all probes, test leads and accessories that are more commonly available you might...
FE 123 & 124 Users Manual
Page 31
... the SCOPE OPTIONS submenu. Highlight SINGLE SHOT. (2x) Accept the set up for a single shot on the input A waveform, do the following : • Connect the probe to the signal to indicate the most recent change in a reading.
... the SCOPE OPTIONS submenu. Highlight SINGLE SHOT. (2x) Accept the set up for a single shot on the input A waveform, do the following : • Connect the probe to the signal to indicate the most recent change in a reading.
FE 123 & 124 Users Manual
Page 37
.... To trigger on a random video line, continue from a trigger waveform. Open the VIDEO TRIGGER submenu. Highlight RANDOM. See Figure 1-17. To choose the isolated trigger probe, select 'EXT' in point of the previous example as follows: Highlight VIDEO on A. Select PAL. Isolated Triggering Use the optically isolated trigger...
.... To trigger on a random video line, continue from a trigger waveform. Open the VIDEO TRIGGER submenu. Highlight RANDOM. See Figure 1-17. To choose the isolated trigger probe, select 'EXT' in point of the previous example as follows: Highlight VIDEO on A. Select PAL. Isolated Triggering Use the optically isolated trigger...
FE 123 & 124 Users Manual
Page 46
... as follows to adapt the Test Tool's voltage readout to this Probe is for High Frequency Measurements. The example below is recommended when you measure high frequency signals in relation to input B: Open the Scope menu. Fluke 123/124 Users Manual The reading now shows the risetime from 10%-90...% of the trace amplitude and the voltage at the cursors in circuits with a model VP40 10:1 Probe. Press ENTER Select 10:1 V
... as follows to adapt the Test Tool's voltage readout to this Probe is for High Frequency Measurements. The example below is recommended when you measure high frequency signals in relation to input B: Open the Scope menu. Fluke 123/124 Users Manual The reading now shows the risetime from 10%-90...% of the trace amplitude and the voltage at the cursors in circuits with a model VP40 10:1 Probe. Press ENTER Select 10:1 V
FE 123 & 124 Users Manual
Page 47
... model VP40 such as supplied with the Test Tool is always adapted correctly to adjust these Probes is not necessary. Other 10:1 Probes however must be adjusted for optimal High Frequency performance. How to its inputs: high frequency adjustment is explained in the voltage ...readout. Observe that the 10 times attenuation of the Probe is compensated in Chapter 2 under 'Using and Adjusting 10:1 Scope Probes'. 1 Using The Test Tool Using a Printer Using a Printer To print a (graphic) hard copy of the present ...
... model VP40 such as supplied with the Test Tool is always adapted correctly to adjust these Probes is not necessary. Other 10:1 Probes however must be adjusted for optimal High Frequency performance. How to its inputs: high frequency adjustment is explained in the voltage ...readout. Observe that the 10 times attenuation of the Probe is compensated in Chapter 2 under 'Using and Adjusting 10:1 Scope Probes'. 1 Using The Test Tool Using a Printer Using a Printer To print a (graphic) hard copy of the present ...
FE 123 & 124 Users Manual
Page 54
...-blade screwdriver. 46 Figure 2-2. Install a new battery pack. Contact your authorized FLUKE Service Center for recycling information. Disconnect the test leads and probes both at the source and at the test tool. 2. Locate the battery access cover on the bottom rear. Fluke 123/124 Users Manual Replacing and Disposing of the battery compartment. 6. Lift... Figure 2-2.) 1. Replacing the Battery Pack 4. Take the battery pack out of the Rechargeable Battery Pack Warning To avoid electrical shock, remove the test leads and probes before replacing the battery pack.
...-blade screwdriver. 46 Figure 2-2. Install a new battery pack. Contact your authorized FLUKE Service Center for recycling information. Disconnect the test leads and probes both at the source and at the test tool. 2. Locate the battery access cover on the bottom rear. Fluke 123/124 Users Manual Replacing and Disposing of the battery compartment. 6. Lift... Figure 2-2.) 1. Replacing the Battery Pack 4. Take the battery pack out of the Rechargeable Battery Pack Warning To avoid electrical shock, remove the test leads and probes before replacing the battery pack.
FE 123 & 124 Users Manual
Page 55
...Fluke 123 use the Fluke BP130 Ni-MH battery pack . 8. You need to the red input A jack. To adjust probes, do the following: 2 Maintaining the Test Tool Using and Adjusting 10:1 Scope Probes • Connect the 10:1 scope probe from the gray input B jack to adjust other scope probes (e.g. Adjusting Scope Probes 47 For Fluke... 124 it is recommended to use the Fluke BP120 Ni-Cd (standard) or BP130 Ni-MH...
...Fluke 123 use the Fluke BP130 Ni-MH battery pack . 8. You need to the red input A jack. To adjust probes, do the following: 2 Maintaining the Test Tool Using and Adjusting 10:1 Scope Probes • Connect the 10:1 scope probe from the gray input B jack to adjust other scope probes (e.g. Adjusting Scope Probes 47 For Fluke... 124 it is recommended to use the Fluke BP120 Ni-Cd (standard) or BP130 Ni-MH...
FE 123 & 124 Users Manual
Page 56
Highlight ADJUST 10:1 PROBE. Open the PROBES submenu. Open the PROBE AC ADJUST submenu. A square wave appears on the screen. 48 Adjust the trimmer screw in the probe housing to normal mode. Return to give an optimum square wave. Highlight PROBE AC ADJUST. Fluke 123/124 Users Manual Open the SCOPE INPUTS menu.
Highlight ADJUST 10:1 PROBE. Open the PROBES submenu. Open the PROBE AC ADJUST submenu. A square wave appears on the screen. 48 Adjust the trimmer screw in the probe housing to normal mode. Return to give an optimum square wave. Highlight PROBE AC ADJUST. Fluke 123/124 Users Manual Open the SCOPE INPUTS menu.
FE 123 & 124 Users Manual
Page 60
Compact Soft Case Soft Carrying Case Isolated Trigger Probe Print Adapter Cable for Windows® 10:1 Scope Probe VP40. Fluke 123/124 Users Manual Optional Accessories Item Software & Cable Carrying Case Kit (Supplied with Fluke 124, 124/S Optically Isolated RS-232 Adapter/Cable. Supplied with Fluke 123/S, 124/S FlukeView® ScopeMeter® Software for Parallel Printers Ordering Code...
Compact Soft Case Soft Carrying Case Isolated Trigger Probe Print Adapter Cable for Windows® 10:1 Scope Probe VP40. Fluke 123/124 Users Manual Optional Accessories Item Software & Cable Carrying Case Kit (Supplied with Fluke 124, 124/S Optically Isolated RS-232 Adapter/Cable. Supplied with Fluke 123/S, 124/S FlukeView® ScopeMeter® Software for Parallel Printers Ordering Code...
FE 123 & 124 Users Manual
Page 70
... Oscilloscope Vertical Frequency Response DC Coupled: excluding probes and test leads (via BB120 Fluke 123: DC to 20 MHz (-3 dB) Fluke 124: DC to 40 MHz (-3 dB) with STL120 1:1 shielded test leads DC to 12.5 MHz (-3 dB) DC to 20 MHz (-6 dB) with VP40 10:1 probe Fluke 123 (optional accessory): DC to 20 MHz (-3... dB) Fluke 124 (standard accessory): DC to 40 MHz (-3 dB) AC Coupled (LF roll off): excluding probes and test leads 10 Hz (-3 dB) with STL120 10 Hz (-3dB) with 10 MΩ...
... Oscilloscope Vertical Frequency Response DC Coupled: excluding probes and test leads (via BB120 Fluke 123: DC to 20 MHz (-3 dB) Fluke 124: DC to 40 MHz (-3 dB) with STL120 1:1 shielded test leads DC to 12.5 MHz (-3 dB) DC to 20 MHz (-6 dB) with VP40 10:1 probe Fluke 123 (optional accessory): DC to 20 MHz (-3... dB) Fluke 124 (standard accessory): DC to 40 MHz (-3 dB) AC Coupled (LF roll off): excluding probes and test leads 10 Hz (-3 dB) with STL120 10 Hz (-3dB) with 10 MΩ...
FE 123 & 124 Users Manual
Page 71
Horizontal Scope Modes Normal, Single, Roll Ranges Normal: equivalent sampling (Fluke 123) ..... 20 ns to 500 ns/div equivalent sampling (Fluke 124) ..... 10 ns to 500 ns/div real time sampling 1 µs to 5 s/div Single (real time 1 µs to 5 s/div Roll (real ... across the screen. 4 Specifications Dual Input Oscilloscope Trigger Screen Update Free Run, On Trigger Source A, B, EXT EXTernal via optically isolated trigger probe ITP120 (optional accessory) Sensitivity A and B (Fluke 123) @ DC to 5 MHz 0.5 divisions or 5 mV @ 25 MHz 1.5 divisions @ 40 MHz 4 divisions Sensitivity A and...
Horizontal Scope Modes Normal, Single, Roll Ranges Normal: equivalent sampling (Fluke 123) ..... 20 ns to 500 ns/div equivalent sampling (Fluke 124) ..... 10 ns to 500 ns/div real time sampling 1 µs to 5 s/div Single (real time 1 µs to 5 s/div Roll (real ... across the screen. 4 Specifications Dual Input Oscilloscope Trigger Screen Update Free Run, On Trigger Source A, B, EXT EXTernal via optically isolated trigger probe ITP120 (optional accessory) Sensitivity A and B (Fluke 123) @ DC to 5 MHz 0.5 divisions or 5 mV @ 25 MHz 1.5 divisions @ 40 MHz 4 divisions Sensitivity A and...
FE 123 & 124 Users Manual
Page 73
...1:1 (shielded) test leads 60 Hz (6 Hz with 10:1 probe 1.5% 50 Hz (5 Hz with 10:1 probe 2% 33 Hz (3.3 Hz with 10:1 probe 5% 10 Hz (1 Hz with 10:1 probe, add probe uncertainty +1%. Dual Input Meter The accuracy of all measurements is ...independent of any signal crest factor. For voltage measurements with 10:1 probe 30% DC Rejection (only VAC 50 dB Common Mode Rejection (CMRR) ....... >100 dB @ DC... 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz (Fluke 123) or 70MHz (Fluke 124) Frequency Range in Continuous Autoset 15 Hz (1 Hz) to 20 MHz (excl.
...1:1 (shielded) test leads 60 Hz (6 Hz with 10:1 probe 1.5% 50 Hz (5 Hz with 10:1 probe 2% 33 Hz (3.3 Hz with 10:1 probe 5% 10 Hz (1 Hz with 10:1 probe, add probe uncertainty +1%. Dual Input Meter The accuracy of all measurements is ...independent of any signal crest factor. For voltage measurements with 10:1 probe 30% DC Rejection (only VAC 50 dB Common Mode Rejection (CMRR) ....... >100 dB @ DC... 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz (Fluke 123) or 70MHz (Fluke 124) Frequency Range in Continuous Autoset 15 Hz (1 Hz) to 20 MHz (excl.
FE 123 & 124 Users Manual
Page 74
... Users Manual Accuracy: @1 Hz to 1 MHz 0.5% +2 counts) @1 to 10 MHz 1.0% +2 counts) @10 to 50 MHz (Fluke 123 2.5% +2 counts) @10 to 70 MHz (Fluke 124 2.5% +2 counts) (50 MHz in Autorange) Full Scale Reading 10 000 counts Duty Cycle (DUTY) Range 2% to 98% Frequency...to 1 MHz 0.5% +2 counts) @1 MHz to 5 MHz 5 degrees Resolution 1 degree as VDC, VAC, VAC+DC, or PEAK (add current probe uncertainty) Temperature (TEMP) ... with optional current probe Ranges......... probe uncertainty) Decibel (dB) 0 dBV 1V 0 dBm (600Ω /50 1 mW referenced to 600Ω or 50Ω dB on VDC,...
... Users Manual Accuracy: @1 Hz to 1 MHz 0.5% +2 counts) @1 to 10 MHz 1.0% +2 counts) @10 to 50 MHz (Fluke 123 2.5% +2 counts) @10 to 70 MHz (Fluke 124 2.5% +2 counts) (50 MHz in Autorange) Full Scale Reading 10 000 counts Duty Cycle (DUTY) Range 2% to 98% Frequency...to 1 MHz 0.5% +2 counts) @1 MHz to 5 MHz 5 degrees Resolution 1 degree as VDC, VAC, VAC+DC, or PEAK (add current probe uncertainty) Temperature (TEMP) ... with optional current probe Ranges......... probe uncertainty) Decibel (dB) 0 dBV 1V 0 dBm (600Ω /50 1 mW referenced to 600Ω or 50Ω dB on VDC,...
FE 123 & 124 Users Manual
Page 79
Max. Frequency for VP40 10:1 Voltage Probe 71 Frequency for BB120 and STL120 Figure 4-2. Max. Input Voltage v.s. Input Voltage v.s. 4 Specifications Safety Figure 4-1.
Max. Frequency for VP40 10:1 Voltage Probe 71 Frequency for BB120 and STL120 Figure 4-2. Max. Input Voltage v.s. Input Voltage v.s. 4 Specifications Safety Figure 4-1.