Fluke 902 HVAC Clamp Meter Datasheet - Page 1
Fluke 902
True-rms HVAC Clamp Meter
Technical Data
Heating, ventilation, air conditioning (HVAC) technicians require a service tool that can consistently keep up with True RMS technology and a CAT III 600 V rating, the Fluke 902 helps technicians do their demands.
The Fluke 902 expands the existing line of variable frequency drives
Features include:
• Capacitance • DC ...
Fluke 902 HVAC Clamp Meter Datasheet - Page 2
Ordering Information
Fluke-902 HVAC Clamp Meter Included AA alkaline batteries (2) Users manual (w/safety information) Soft carrying case TL75 Test Leads (1 pair) 80BK Integrated DMM Temperature Probe (1)
Optional accessories
H3 Clamp Meter Holster
• Rugged fabric holster includes
flap for lead storage and built-in
belt loop
• Also used on Fluke 320 and
330 Series Clamp Meters
TL223 ...
FE 902 Users Manual - Page 1
Printed in China. All product names are trademarks of their respective companies. ®
902
HVAC Clamp Meter
Users Manual
PN 2547887 May 2006 Rev. 1, 3/07 © 2006-2007 Fluke Corporation. All rights reserved.
FE 902 Users Manual - Page 5
Temperature Measurement 15 5. Proper AC Current Measurement 17 6. Testing a Flame Rod 13 4. Display Features 8 3. Battery Replacement 22
iii List of Figures
Figure
Title
Page
1. 902 HVAC Clamp Meter Features 6 2. Display Features 9
List of Tables
Table
Title
Page
1. 902 HVAC Clamp Meter Features 7 2.
FE 902 Users Manual - Page 7
... HVAC Clamp Meter ("the Meter") that measures: • AC current • DC current (up to 200 µA for flame rod testing) • AC and DC voltages • Capacitance • Resistance • Continuity • Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case...
FE 902 Users Manual - Page 9
...could damage the Meter or the equipment under test. Contact with voltages higher than 600 V or a frequency higher than 400 Hz fundamental.
The Meter may be rendered. • Never use and
follow these instructions: • Read the Users Manual before use the Meter on a circuit with the conductor could result in the
Users Manual; HVAC Clamp Meter Contacting Fluke
Safety Information...
FE 902 Users Manual - Page 10
...where the low batteries affect the readings, the Meter locks and no measurements can lead to local and national safety codes. Individual protective equipment must be made until the..., replace the batteries as soon as the low battery indicator (B) appears. Such voltages pose a shock hazard.
• Clean the case with voltages above 60 V dc or 30 V ac rms or 42 V ac peak. 902 Users Manual
...
FE 902 Users Manual - Page 11
...W
Risk of danger.
HVAC Clamp Meter Symbols
Symbols
The following symbols are found on the Meter or in this product as unsorted municipal waste. Important information. T
Double insulation
B
Battery
)
Complies with Canadian and US Standards
P
Conforms to relevant Australian standards
Inspected and licensed by TÜV Product Services
5 See Users Manual.
Conforms to relevant...
FE 902 Users Manual - Page 12
902 Users Manual
Getting Acquainted with the Meter
Refer to Figures 1 and 2 and Tables 1 and 2 to become more acquainted with the Meter's features.
COM CAT µAV
600V efu0001.eps
Figure 1. 902 HVAC Clamp Meter Features
6
FE 902 Users Manual - Page 16
V 2. Turn the rotary switch to take the measurement. The Meter reading appears on the display. The display reflects the chosen voltage mode.
4. 902 Users Manual
Using the Meter
AC and DC Voltage Measurement
To measure AC or DC voltage: 1. Use the test leads to .
3. Insert the test leads into the Meter. Press A to choose AC or DC voltage. Note When a measured...
FE 902 Users Manual - Page 18
... to G. 4. Turn the rotary switch on the Meter to Figure 3): 1. Turn the heating unit off and locate the wire between the
flame sensor probe and control-module wire.
5. Refer to the heating unit documentation for HVAC flame rod testing. 902 Users Manual
Microamps µA Measurement
The µA dc (G) function on the Meter is primarily for what the
desired reading...
FE 902 Users Manual - Page 20
... 30 V ac, 42 V peak or 60 V dc to take the measurement. The reading appears on the display.
902 Users Manual 1. The display reflects the chosen temperature mode. 4. Connect the 80BK Integrated DMM Temperature
Probe to the input jacks noting correct polarity of the probe. 2. Note To meet stated accuracy, the 80BK and Meter must be at the same...
FE 902 Users Manual - Page 22
... jaws, below the horizontal line located on the clamp. Also note that the measured wire be measured at a time for a correct measurement (see Figure 1. 902 Users Manual
Capacitance
Turn off circuit power, then disconnect and discharge the capacitor before making current
measurements. • Do not hold the Meter anywhere beyond
the tactile barrier, see Figure...
FE 902 Users Manual - Page 24
... the minimum and maximum input values. K is displayed. 3. When a new high or low is detected, the Meter beeps. Press Jto step through the minimum (MIN) and present readings. 4. To pause MIN MAX recording without erasing..., press Jfor at least two seconds.
18 Put the Meter into the desired measurement function
and range. 2. 902 Users Manual
Backlight
Press C to toggle the backlight on .
FE 902 Users Manual - Page 30
902 Users Manual
General Specifications
Operating Temperature -10 °C to +50 °C
Storage Temperature -40 °C to +60 °C
Operating Humidity
Non condensing (< 10 °C)
90 % RH (10 °C to 30 °C)
75 % RH (30 °C to 40 °C)
45 % RH (40 °C to 50 °C)
(Without Condensation)
Operating Altitude
2500 meters above mean sea level
Storage Altitude...