Fluke 1623 Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 1623 manuals!
Problems with Fluke 1623?

Ask a Question

Most Recent Fluke 1623 Questions

Fluke 1623-2 Not Powering Up/turning On
I have a fluke 1623-2 and although not store bought, appears to have never been used. With new batte...
(Posted by aspivey97 5 years ago)
How To Connect A Probe For 3 Pole Method
(Posted by rajeshslvrj 8 years ago)

Fluke 1623 Videos

?????????? Fluke 1623
Duration: 1:00
Total Views: 19

Popular Fluke 1623 Manual Pages

Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 2

...model kit comes with the 1623 or 1625 tester, test leads, 4 earth ground stakes, 3 cable reels with wire, 2 clamps, batteries, and manual-all four types of use . Temperature coefficient Intrinsic error Operating error...of earth ground measurement: • 3- the instrument can perform all inside a rugged Fluke carrying case. 1623 Specifications General Display:1999 digit LCD User ...
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 3

...RH[k7]• • •RS[k7]/RA[7 0.2 % Measurement is not performed if the current through the current clamp is too low 3 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers Intrinsic error ± (2 % rdg + 3 d) Operating error ± (5 % rdg + 3 d) Measuring principle: Current and voltage measurement Measuring voltage Vm = 48 V ac Short-circuit current > 50 mA Measure...
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 4

... with current clamp (RA Switch position RA 4-pole Resolution 0.001 7 to 10 7 Measuring range 0.001 7 to 199.9 7 Intrinsic error ± (7 % rdg + 3 d) Operating error ± (10 % rdg + 5 d) Measuring principle: Stakeless measurement of RS, and RH with the recommended current clamps at the minimum distance specified. 4 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 5

...from the distribution system. 5 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers The operating error applies under the rated operating ...1625 Users Manual. and 4-pole with/without clip-on current transformer, resistance 2-pole with additional functions Interference voltage and frequency, earthing resistance 3- the instrument can be 3 V; • resistance of the auxiliary earth...
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 6

... + RH > 10 k7) 250 mm x 133 mm x 187 mm (9.75 in x 5.25 in x 7.35 in function R* 120 dB (162/3, 50 , 60, 400 Hz) Urms = 250 V 6 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers Limits of error Climate class Type of rdg + 5 digit) Measuring sequence Internal resistance Max.
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 8

...manually or automatically (AFC), 55 Hz (R*) 120 dB (162/3, 50, 60, 400 Hz) Max. overload Current and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with a fixed frequency 30 sec. electrode resistance Resolution 0.001 7 0.01 7 0.1 7 17 10 7 Intrinsic error* Operating error... Fluke Corporation 1623 and 1625 GEO Earth Ground Testers ...
Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet - Page 9

....9 7 300 7 to 2999 7 Resolution 0.001 7 0.01 7 0.1 7 17 Intrinsic error ± (2 % of measuring adjustment. 2-pole 9 Fluke Corporation 1623 and 1625 GEO Earth Ground Testers incl. reversal of polarity (2-pole or 4-pole) b 3 V ac or dc, with ... V ac, square pulse > 250 mA ac 94, 105, 111, 128 Hz selected manually or automatically (AFC) Measuring range 0.020 7 to 300 k7 Display range 0.001 7 ...
FE 1623 Users Manual - Page 1

Printed in USA All product names are trademarks of their respective companies. ® 1623 Earth/Ground Tester Users Manual PN 2560327 January 2006 © 2006 Fluke Corporation, All rights reserved.
FE 1623 Users Manual - Page 11

...; E Connection "S" for probe 4 mm ∅ F Connection A for sensing current test clamp G Connection "ES" for earth electrode probe 4 mm ∅ H Connection "E" for the earth/ground electrode to be measured 4 mm ∅ I Battery compartment for starting the selected measurement function. Earth/Ground Tester Safety Regulations 2 1 11 3 FLUKE 1623 max 50 V P2 S 4 5 6 P1 ES 7 plus...
FE 1623 Users Manual - Page 12

Fluke 1623 Users Manual Accessories The following standard accessories were shipped with your Tester: • 6 alkaline AA - type (LR6) batteries • 2 measuring leads 1,5 m • 1 connector cable (for RA 2-pole measurements) • 2 alligator clips • 1 Users Manual Carrying Case The part number for the carrying case for the 1623 Earth/Ground Tester and accessories such as the ...
FE 1623 Users Manual - Page 13

Earth/Ground Tester Accessories Table 2. Basic (Includes manual, 2 leads and 2 clips) Earth Ground Tester - Models and Accessories Table 2 lists the models and accessories. Models and Accessories Description Earth Ground Tester - Fully Loaded (Includes manual, 2 leads and 2 clips, ES162P4, EI-1623) Service Replacement Kit (Includes 2 Leads, 2 Clips) Stake Set for 3 Pole Measurement (Includes...
FE 1623 Users Manual - Page 17

... until a new measurement is started or the rotary switch is in earth/dirt. The "active" symbol indicates that a measurement is turned. 1 2 E ES S H FLUKE 1623 Earth/Ground Tester max 50 V P2 S P1 ES/P1 ES E/C1 S/P2 H/C2 plus FLUKE E >20 m >20 m 3 4 active E ES S H E ES S H Figure 5. Earth/Ground Tester Setup RA 4-pole Measurements Refer to H/C2 and S/P2 as shown below...
FE 1623 Users Manual - Page 21

Stakeless Ground Loop Measurement edv007.eps 13 1 2 E H FLUKE 1623 max 50 V plus FLUKE Earth/Ground Tester Setup 3 4 active E H E H Figure 8.
FE 1623 Users Manual - Page 23

...new test performed. Troubleshooting edv008.eps 15 To be regarded as reliable. 1 U ext >Limit 2 E SH H >Limit E ES S H 3 S >Limit 4 E ES S H E SH FLUKE 1623 max 50 V P2 S plus FLUKE E/C1 S/P2...close together, the magnetic field of a "Stakeless ground loop measurement" reliable? Earth/Ground Tester Troubleshooting conditions (depending mainly on the soil resistivity) this...
FE 1623 Users Manual - Page 29

... avoid possible damage by leaking battery electrolyte. 21 To register your product, visit register.fluke.com Storage In case the instrument is either not used or stored for damage in transit. Earth/Ground Tester Service Service If you suspect that the tester has failed, review this manual to make sure you are operating it , postage paid, to the nearest...

Fluke 1623 Reviews

Do you have an experience with the Fluke 1623 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 1623 Search Terms

The following terms are frequently used to search for Fluke 1623 support:

Ask a New Question
Use the box below to post a new question about Fluke 1623.
Manuals / Documents
Download any of our Fluke 1623 manuals for free!

We have the following 2 documents available for the Fluke 1623:
  • FE 1623 Users Manual
  • Fluke 1623 and 1625 Geo Earth Ground Testers Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1623 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 1623 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls