OpenSwitch OPX Installation Guide with Enhancement Package Release 3.1.0
Page 6
...of all disk partitions except ONIE. • Update ONIE - Manually configure your switch or the platform-specific Installation Guide at www.dell.com/support. System setup Verify that results in an unsuccessful installation, perform Uninstall OS first to clear the partitions if there is ... the support binary. 6 Installation ONIE discovers network information including the DHCP server, connects to an image server, options to point to the console serial port - See opencompute.org for repair, debugging, and forensics. • Uninstall OS - 3 Installation You can install OpenSwitch OPX ...
...of all disk partitions except ONIE. • Update ONIE - Manually configure your switch or the platform-specific Installation Guide at www.dell.com/support. System setup Verify that results in an unsuccessful installation, perform Uninstall OS first to clear the partitions if there is ... the support binary. 6 Installation ONIE discovers network information including the DHCP server, connects to an image server, options to point to the console serial port - See opencompute.org for repair, debugging, and forensics. • Uninstall OS - 3 Installation You can install OpenSwitch OPX ...
Open Networking Hardware Diagnostic Guide December 2021
Page 6
This tool tests for the next boot. ONIE expansion To view all the tests pass, the diagnostic tools close. onie-boot-mode onie-fwpkg onie-console onie-nos-install onie-discovery-start onie-self-update onie-discovery-stop onie-support onie-syseeprom onie-sysinfo onie-uninstaller Topics: • Boot processes • ...
This tool tests for the next boot. ONIE expansion To view all the tests pass, the diagnostic tools close. onie-boot-mode onie-fwpkg onie-console onie-nos-install onie-discovery-start onie-self-update onie-discovery-stop onie-support onie-syseeprom onie-sysinfo onie-uninstaller Topics: • Boot processes • ...
Open Networking Hardware Diagnostic Guide December 2021
Page 9
... the default username and password. ● Username (BMC): admin ● Username (ONIE and DIAG OS): root ● Password (uppercase): ! onie-boot-mode onie-fwpkg onie-console onie-nos-install onie-discovery-start onie-self-update onie-discovery-stop onie-support onie-syseeprom onie-sysinfo onie-uninstaller Topics: • ONIE installation •...
... the default username and password. ● Username (BMC): admin ● Username (ONIE and DIAG OS): root ● Password (uppercase): ! onie-boot-mode onie-fwpkg onie-console onie-nos-install onie-discovery-start onie-self-update onie-discovery-stop onie-support onie-syseeprom onie-sysinfo onie-uninstaller Topics: • ONIE installation •...
Open Networking Hardware Diagnostic Guide December 2021
Page 10
...the serial port at 115200 baud rate. The selected entry, displaying *, runs automatically in ONIE Rescue mode. based boards. ● Check the console (UART-0/1) used on your system must meet the following requirements: ● Allows a change to make a selection. Therefore, the ONIE images ... firmware interface (UEFI) ONIE-based USB to change . ONIE UEFI-based installation using Embed mode: To install ONIE UEFI on the console. ● The log messages included in this guide are specified using Rangeley or Centerton CPU- Confirm that messages display on your system...
...the serial port at 115200 baud rate. The selected entry, displaying *, runs automatically in ONIE Rescue mode. based boards. ● Check the console (UART-0/1) used on your system must meet the following requirements: ● Allows a change to make a selection. Therefore, the ONIE images ... firmware interface (UEFI) ONIE-based USB to change . ONIE UEFI-based installation using Embed mode: To install ONIE UEFI on the console. ● The log messages included in this guide are specified using Rangeley or Centerton CPU- Confirm that messages display on your system...
Open Networking Hardware Diagnostic Guide December 2021
Page 12
... ONIE Service Discovery Info: Found static url: file:///lib/onie/onie-updater [ 29.744855] random: nonblocking pool is removed. Please press Enter to activate this console. Embed ONIE menu 10. Platform : x86_64-dell__c2538-r0 Version : x.xx.x.x Build Date: 2016-04-26T09:14-0700 [ 4.066378] dummy-irq: no busid passed, refusing all...
... ONIE Service Discovery Info: Found static url: file:///lib/onie/onie-updater [ 29.744855] random: nonblocking pool is removed. Please press Enter to activate this console. Embed ONIE menu 10. Platform : x86_64-dell__c2538-r0 Version : x.xx.x.x Build Date: 2016-04-26T09:14-0700 [ 4.066378] dummy-irq: no busid passed, refusing all...
Open Networking Hardware Diagnostic Guide December 2021
Page 14
.../sda: 31277232 sectors, 14.9 GiB Logical sector size: 512 bytes Disk identifier (GUID): 763E53FF-B894-40FD-B0F9-FBAE2ED4B0B5 Partition table holds up to activate this console. Verify that you are running the correct kernel in EFI Shell Boot0006* UEFI: KingstonDataTraveler 2.01.00 14 14 ONIE installation instructions Verify the ONIE Linux...
.../sda: 31277232 sectors, 14.9 GiB Logical sector size: 512 bytes Disk identifier (GUID): 763E53FF-B894-40FD-B0F9-FBAE2ED4B0B5 Partition table holds up to activate this console. Verify that you are running the correct kernel in EFI Shell Boot0006* UEFI: KingstonDataTraveler 2.01.00 14 14 ONIE installation instructions Verify the ONIE Linux...
Open Networking Hardware Diagnostic Guide December 2021
Page 20
CAUTION: Restoring factory defaults erases any installed OS and requires a long time to activate the console. 3. Restore the factory defaults on your system from the Grub menu using the onie-uninstaller command...internal mass storage device: /dev/sda5 (300MB) Percent complete: 100% Erase complete. Rebooting... done. Sent SIGTERM to the ONIE console. Use the up and down arrow keys to select which entry is going down NOW! Deleting partition 4 from /dev/sda Erasing... ONIE: Rescue. Info: Unmounting kernel filesystems The system is highlighted. machine restart 20 Dell EMC DIAG OS
CAUTION: Restoring factory defaults erases any installed OS and requires a long time to activate the console. 3. Restore the factory defaults on your system from the Grub menu using the onie-uninstaller command...internal mass storage device: /dev/sda5 (300MB) Percent complete: 100% Erase complete. Rebooting... done. Sent SIGTERM to the ONIE console. Use the up and down arrow keys to select which entry is going down NOW! Deleting partition 4 from /dev/sda Erasing... ONIE: Rescue. Info: Unmounting kernel filesystems The system is highlighted. machine restart 20 Dell EMC DIAG OS
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 4
... Power cable clip installation...47 Chapter 6: Fans...49 Components...49 Fan module installation...50 Fan module replacement...51 Chapter 7: Management ports...52 RJ45 console port access...52 MicroUSB-B console port access...53 USB storage mount...54 Before you install an OS...54 Check your switch...55 ONIE service discovery...56 Chapter 8: Specifications...for class A equipment...61 Korean certification of compliance...61 Safety standards and compliance agency certifications 62 Electromagnetic compatibility ...62 Product recycling and disposal...63 Chapter 9: Dell EMC support...64 4 Contents
... Power cable clip installation...47 Chapter 6: Fans...49 Components...49 Fan module installation...50 Fan module replacement...51 Chapter 7: Management ports...52 RJ45 console port access...52 MicroUSB-B console port access...53 USB storage mount...54 Before you install an OS...54 Check your switch...55 ONIE service discovery...56 Chapter 8: Specifications...for class A equipment...61 Korean certification of compliance...61 Safety standards and compliance agency certifications 62 Electromagnetic compatibility ...62 Product recycling and disposal...63 Chapter 9: Dell EMC support...64 4 Contents
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 9
... A 7. RJ45 Ethernet port 1. Three 100GbE QSFP28 ports The S5212F-ON DC switch I /O-side view: 4. 3. MicroUSB-B console port 9. LED status icons The S5224F-ON switch I /O-side view: 2. Stack ID 8. Twelve 25GbE SFP28 ports 3. Eight 100GbE QSFP28 ports 5. MicroUSB-B console port 5. Stack ID 4. Stack ID 4. Reset button 7. Four 100GbE QSFP28 ports The S5212F-ON AC...
... A 7. RJ45 Ethernet port 1. Three 100GbE QSFP28 ports The S5212F-ON DC switch I /O-side view: 4. 3. MicroUSB-B console port 9. LED status icons The S5224F-ON switch I /O-side view: 2. Stack ID 8. Twelve 25GbE SFP28 ports 3. Eight 100GbE QSFP28 ports 5. MicroUSB-B console port 5. Stack ID 4. Stack ID 4. Reset button 7. Four 100GbE QSFP28 ports The S5212F-ON AC...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 10
..., one Micro-USB type-B console port, one 10/100/1000 Base-T Ethernet management port, one USB type-A port for the external storage, and for the S5212F-ON switch that has the management ports on the PSU-side of the switch. Fan modules 4. AC PSU units The S5224F-ON switch PSU-side view...: 10 S5200F-ON Series switch DC PSUs 9. RJ45 Ethernet port 8. Fan modules 8. Luggage tag 7. 5. RJ45 console port The S5212F-ON AC and DC switches have a reset button on the I /O-side of...
..., one Micro-USB type-B console port, one 10/100/1000 Base-T Ethernet management port, one USB type-A port for the external storage, and for the S5212F-ON switch that has the management ports on the PSU-side of the switch. Fan modules 4. AC PSU units The S5224F-ON switch PSU-side view...: 10 S5200F-ON Series switch DC PSUs 9. RJ45 Ethernet port 8. Fan modules 8. Luggage tag 7. 5. RJ45 console port The S5212F-ON AC and DC switches have a reset button on the I /O-side of...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 11
Luggage tag 7. USB Type A 6. RJ45 console port 1. Fans 8. 1. Holes for ground lug installation Features The S5200F-ON Series switch offers the following features: ● Ports: ○ S5212F-ON-twelve 25GbE SFP28 ports and three 100GbE QSFP28 ports ○ S5224F-ON-twenty-four 25GbE SFP28 ports and four... 200GbE QSFP-DD ports ○ S5296F-ON-ninety-six 25GbE SFP28 ports and eight 100GbE QSFP28 ports ● One MicroUSB-B console port ● One RJ45 console port ● One USB Type A port for more file storage ● Four-core Intel Denverton central processing unit (CPU)...
Luggage tag 7. USB Type A 6. RJ45 console port 1. Fans 8. 1. Holes for ground lug installation Features The S5200F-ON Series switch offers the following features: ● Ports: ○ S5212F-ON-twelve 25GbE SFP28 ports and three 100GbE QSFP28 ports ○ S5224F-ON-twenty-four 25GbE SFP28 ports and four... 200GbE QSFP-DD ports ○ S5296F-ON-ninety-six 25GbE SFP28 ports and eight 100GbE QSFP28 ports ● One MicroUSB-B console port ● One RJ45 console port ● One USB Type A port for more file storage ● Four-core Intel Denverton central processing unit (CPU)...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 52
... access • USB storage mount • Before you install an OS • Check your switch • ONIE service discovery RJ45 console port access For the S5224F-ON, S5232F-ON, and S5248F-ON switches, the management ports are on the PSU-side of the switch. For the S5212F-ON ... the I/O-side of the switch. Out-of -band management port (top); RJ45 console port (bottom) The S5212F-ON AC switch management ports: 52 Management ports Out-of -band management port (top); Your output may vary. The S5224F-ON, S5232F-ON, or S5248F-ON switch management ports: 1. NOTE: The output...
... access • USB storage mount • Before you install an OS • Check your switch • ONIE service discovery RJ45 console port access For the S5224F-ON, S5232F-ON, and S5248F-ON switches, the management ports are on the PSU-side of the switch. For the S5212F-ON ... the I/O-side of the switch. Out-of -band management port (top); RJ45 console port (bottom) The S5212F-ON AC switch management ports: 52 Management ports Out-of -band management port (top); Your output may vary. The S5224F-ON, S5232F-ON, or S5248F-ON switch management ports: 1. NOTE: The output...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 53
...port number, for example, your terminal software emulation program, such as follows: Management ports 53 Connect the USB-A end of cable into the switch console port. 2. Open your laptop). 2. Confirm that is disconnected from the panel or server, your switch may not boot. Out-of -band ... emulation program are sent to the serial port can support the required 115200 baud rate. Select the correct com port. 7. 1. RS-232 console port (bottom) The S5212F-ON DC switch management ports: 1. Out-of -band management port (top); Install the provided RJ45 connector-side of...
...port number, for example, your terminal software emulation program, such as follows: Management ports 53 Connect the USB-A end of cable into the switch console port. 2. Open your laptop). 2. Confirm that is disconnected from the panel or server, your switch may not boot. Out-of -band ... emulation program are sent to the serial port can support the required 115200 baud rate. Select the correct com port. 7. 1. RS-232 console port (bottom) The S5212F-ON DC switch management ports: 1. Out-of -band management port (top); Install the provided RJ45 connector-side of...
EMC PowerSwitch S5200F-ON Series Installation Guide February 2022
Page 55
... Check your switch, see the Open Networking Hardware Diagnostic Guide at the ONIE prompt. Run the onie-sysinfo command at www.dell.com/support. ONIE Install boots with ONIE Discovery Service (factory default boot) ONIE: Rescue Starts ONIE without ONIE Discovery Service Useful... installed OS During the initial setup, the switch boots to configure your switch To confirm that ONIE is working properly, use the RJ45 or MicroUSB console port. NOTE: After you have securely installed and powered on the S5200F-ON Series switch, to ONIE Install. |*ONIE: Install OS | | ONIE: Rescue...
... Check your switch, see the Open Networking Hardware Diagnostic Guide at the ONIE prompt. Run the onie-sysinfo command at www.dell.com/support. ONIE Install boots with ONIE Discovery Service (factory default boot) ONIE: Rescue Starts ONIE without ONIE Discovery Service Useful... installed OS During the initial setup, the switch boots to configure your switch To confirm that ONIE is working properly, use the RJ45 or MicroUSB console port. NOTE: After you have securely installed and powered on the S5200F-ON Series switch, to ONIE Install. |*ONIE: Install OS | | ONIE: Rescue...
EMC PowerSwitch S5200-ON Series BMC User Guide March 2021
Page 6
... with kernel 4.9.30. Use ipmitool for Trade Agreement Act-qualified (TAA) switches. NOTE: The BMC out-of the network interface using ipmitool from the microprocessor console: ○ # ipmitool lan set 1 ipaddr 6 Hardware and software support NOTE: Although there are : ● Linux version: 4.9.30 ● ipmitool version: 1.8.18 ● ipmi driver that...
... with kernel 4.9.30. Use ipmitool for Trade Agreement Act-qualified (TAA) switches. NOTE: The BMC out-of the network interface using ipmitool from the microprocessor console: ○ # ipmitool lan set 1 ipaddr 6 Hardware and software support NOTE: Although there are : ● Linux version: 4.9.30 ● ipmitool version: 1.8.18 ● ipmi driver that...
EMC PowerSwitch S5200-ON Series BMC User Guide March 2021
Page 30
... admin/admin (but only valid for the IPMI commands for mc info and change of the administrator password) BMC console login username/password sysadmin/superuser BMC console login username/password - after a switch restore Name BMC OOB Setting Enabled for non-TAA and disabled for TAA ... to default Disabled BMC WEB Enabled for non-TAA and disabled for TAA BMC console - after restore to confirm change administrator password) admin/admin BMC WEB - after restore to default Disabled BMC console Enabled for non-TAA and disabled for TAA BMC WEB - after a switch restore...
... admin/admin (but only valid for the IPMI commands for mc info and change of the administrator password) BMC console login username/password sysadmin/superuser BMC console login username/password - after a switch restore Name BMC OOB Setting Enabled for non-TAA and disabled for TAA ... to default Disabled BMC WEB Enabled for non-TAA and disabled for TAA BMC console - after restore to confirm change administrator password) admin/admin BMC WEB - after restore to default Disabled BMC console Enabled for non-TAA and disabled for TAA BMC WEB - after a switch restore...
EMC PowerSwitch S5200-ON Series BMC User Guide March 2021
Page 38
...; ipmi_evt-initial script the runs the imput getevt -s command for example, Terminal mode. ○ ipmiutil sol (isol)-start or stop an IPMI serial-over-LAN console session. ○ ipmiutil sunoem (isunoem)-Sun OEM functions. ○ ipmiutil wdt (iwdt)-show and set the IPMI system event log (SEL) time according to the...
...; ipmi_evt-initial script the runs the imput getevt -s command for example, Terminal mode. ○ ipmiutil sol (isol)-start or stop an IPMI serial-over-LAN console session. ○ ipmiutil sunoem (isunoem)-Sun OEM functions. ○ ipmiutil wdt (iwdt)-show and set the IPMI system event log (SEL) time according to the...