EMC SmartFabric OS10 User Guide Release 10.5.1
Page 31
... expired. For more information, see Zero-touch deployment. If OS10 is pre-installed on the MX9116n Fabric Switching Engine and MX5108n Ethernet Switch. MX Ethernet I/O modules On Dell EMC PowerEdge MX Ethernet I/O modules, OS10 is factory-installed on a switch, zero-touch deployment...OS10 A switch may come with a single partition. Change the default admin password after the trial period expires. Node.1-Unit.1:PRI [event], Dell EMC (OS10) %LADF_LIC_EVAL_PRD_NOTICE: Evaluation license time limit notice. You can perform these tasks: ● Check the OS10 version. ● Upgrade...
... expired. For more information, see Zero-touch deployment. If OS10 is pre-installed on the MX9116n Fabric Switching Engine and MX5108n Ethernet Switch. MX Ethernet I/O modules On Dell EMC PowerEdge MX Ethernet I/O modules, OS10 is factory-installed on a switch, zero-touch deployment...OS10 A switch may come with a single partition. Change the default admin password after the trial period expires. Node.1-Unit.1:PRI [event], Dell EMC (OS10) %LADF_LIC_EVAL_PRD_NOTICE: Evaluation license time limit notice. You can perform these tasks: ● Check the OS10 version. ● Upgrade...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 33
...did not get upgraded. Select the Available Downloads tab on a local server. Read the Dell End User License Agreement, and then scroll to unpack a .tar file on an MX9116n and MX5108n switch, see the Dell EMC SmartFabric OS10 Release Notes-Release 10.5.0. Select how to upgrade OS10 on a Linux ...server or from www.dell.com/support/. For example, to the end of a .tar file. Locate...
...did not get upgraded. Select the Available Downloads tab on a local server. Read the Dell End User License Agreement, and then scroll to unpack a .tar file on an MX9116n and MX5108n switch, see the Dell EMC SmartFabric OS10 Release Notes-Release 10.5.0. Select how to upgrade OS10 on a Linux ...server or from www.dell.com/support/. For example, to the end of a .tar file. Locate...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 34
...image cancel 6. The image install command installs the downloaded image to the system. The firmware upgrade is not reversible. NOTE: On an MX9116n Fabric Switching Engine and MX5108n Ethernet Switch, if you had modified text files or installed custom packages, they would not be reflected in ... any staged firmware update using the boot system {active | standby} command does not have any effect and might not be available with Dell EMC SmartFabric OS10 This reload takes a longer time than usual. for software upgrades. The other image remains standby, used as a pending...
...image cancel 6. The image install command installs the downloaded image to the system. The firmware upgrade is not reversible. NOTE: On an MX9116n Fabric Switching Engine and MX5108n Ethernet Switch, if you had modified text files or installed custom packages, they would not be reflected in ... any staged firmware update using the boot system {active | standby} command does not have any effect and might not be available with Dell EMC SmartFabric OS10 This reload takes a longer time than usual. for software upgrades. The other image remains standby, used as a pending...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 42
... later releases. Click Key Available for an ONIE switch without an OS installed; Enter the device service tag you must have a Dell EMC ProSupport or ProSupport Plus contract on an MX9116n and MX5108n switch, see Download OS10 image, Installation using your local device. 6. Select how to ONIE: Install OS mode. Download OS10...
... later releases. Click Key Available for an ONIE switch without an OS installed; Enter the device service tag you must have a Dell EMC ProSupport or ProSupport Plus contract on an MX9116n and MX5108n switch, see Download OS10 image, Installation using your local device. 6. Select how to ONIE: Install OS mode. Download OS10...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 69
... the chassis where the module is used in the OS10 command-line prompt. CLI Basics 69 The module can be either MX9116n or MX5108n. The MX7000 series switch, not the Dell EMC SmartFabric OS10, automatically sets the default hostname using the no hostname command. Syntax Parameters Default Command Mode Usage Information Example...
... the chassis where the module is used in the OS10 command-line prompt. CLI Basics 69 The module can be either MX9116n or MX5108n. The MX7000 series switch, not the Dell EMC SmartFabric OS10, automatically sets the default hostname using the no hostname command. Syntax Parameters Default Command Mode Usage Information Example...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 161
... ntp authenticate command to hidden encryption. ● key-Enter the authentication key. Example OS10(config)# ntp authentication-key 1200 md5 0 dell Supported Releases 10.2.0E or later System management 161 delay: OS10(config)# 0.000 -50.000 0.000 NTP commands ntp authenticate Enables ...parameter configured in release 10.4.0E(R3S). Also supported in SmartFabric mode starting in release 10.4.0E(R3S). Supported on the MX9116n and MX5108n switches in Full Switch mode starting in release 10.5.0.1. Example OS10(config)# ntp authenticate Supported Releases 10.2.0E or...
... ntp authenticate command to hidden encryption. ● key-Enter the authentication key. Example OS10(config)# ntp authentication-key 1200 md5 0 dell Supported Releases 10.2.0E or later System management 161 delay: OS10(config)# 0.000 -50.000 0.000 NTP commands ntp authenticate Enables ...parameter configured in release 10.4.0E(R3S). Also supported in SmartFabric mode starting in release 10.4.0E(R3S). Supported on the MX9116n and MX5108n switches in Full Switch mode starting in release 10.5.0.1. Example OS10(config)# ntp authenticate Supported Releases 10.2.0E or...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 163
...Switch mode starting in release 10.5.0.1 The no version of hosts you configure, as many polls to have priority over other servers. Dell Technologies recommends limiting the number of this peer to the NTP hosts can configure multiple time-serving hosts. System management 163 OS10(config...)# ntp master 6 Supported Releases 10.2.0E or later ntp server Configures an NTP time-serving host. Supported on the MX9116n and MX5108n switches in Full Switch mode starting in NTP packets. To determine which server to synchronize with. From these time-serving hosts...
...Switch mode starting in release 10.5.0.1 The no version of hosts you configure, as many polls to have priority over other servers. Dell Technologies recommends limiting the number of this peer to the NTP hosts can configure multiple time-serving hosts. System management 163 OS10(config...)# ntp master 6 Supported Releases 10.2.0E or later ntp server Configures an NTP time-serving host. Supported on the MX9116n and MX5108n switches in Full Switch mode starting in NTP packets. To determine which server to synchronize with. From these time-serving hosts...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 303
...port does not use the show inventory media command to servers, use external transceivers and always displays as Dell EMC Qualified. None. On the MX9116n Fabric Switching Engine and MX5108n Ethernet Switch, server-facing interfaces are on the backplane and are enabled by ...corresponding to which you want to view the optical wavelength details. show inventory media System Inventory Media Node/Slot/Port Category Media Serial Dell EMC Number Qualified 1/1/1 Not Present 1/1/2 SFP+ SFP+ 10GBASE SR AM70843 true 1/1/3 Not Present 1/1/4 SFP+ SFP+ 10GBASE SR ...
...port does not use the show inventory media command to servers, use external transceivers and always displays as Dell EMC Qualified. None. On the MX9116n Fabric Switching Engine and MX5108n Ethernet Switch, server-facing interfaces are on the backplane and are enabled by ...corresponding to which you want to view the optical wavelength details. show inventory media System Inventory Media Node/Slot/Port Category Media Serial Dell EMC Number Qualified 1/1/1 Not Present 1/1/2 SFP+ SFP+ 10GBASE SR AM70843 true 1/1/3 Not Present 1/1/4 SFP+ SFP+ 10GBASE SR ...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 304
...None Not configured EXEC None OS10# show inventory media System Inventory Media Node/Slot/Port Category Media Serial Dell EMC Number Qualified 1/1/1 FIXED INTERNAL true 1/1/2 FIXED INTERNAL true 1/1/3 FIXED INTERNAL true 1/1/4 FIXED INTERNAL ...INTERNAL true 1/1/7 FIXED INTERNAL true 1/1/8 FIXED INTERNAL true ... Example: MX9116n Fabric Engine OS10# show inventory media System Inventory Media Node/Slot/Port Category Media Serial Dell EMC Number Qualified 1/1/1 FIXED INTERNAL true 1/1/2 FIXED INTERNAL true 1/1/3 FIXED...
...None Not configured EXEC None OS10# show inventory media System Inventory Media Node/Slot/Port Category Media Serial Dell EMC Number Qualified 1/1/1 FIXED INTERNAL true 1/1/2 FIXED INTERNAL true 1/1/3 FIXED INTERNAL true 1/1/4 FIXED INTERNAL ...INTERNAL true 1/1/7 FIXED INTERNAL true 1/1/8 FIXED INTERNAL true ... Example: MX9116n Fabric Engine OS10# show inventory media System Inventory Media Node/Slot/Port Category Media Serial Dell EMC Number Qualified 1/1/1 FIXED INTERNAL true 1/1/2 FIXED INTERNAL true 1/1/3 FIXED...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 315
For detailed information, see the Dell EMC PowerEdge MX7000 documentation. ● The MX9116n Fabric Switching Engine is automatically placed in Full Switch and SmartFabric modes. The Expander Module offers: ○ Sixteen 25GE server-facing ports ○...Switch-Operating-Mode : Smart Fabric Mode To change the mode using the OS10 CLI. PowerEdge MX Ethernet I /O modules The Dell EMC PowerEdge MX7000 supports the following Ethernet modules: MX9116n Fabric Switching Engine, MX7116n Fabric Expander Module, and MX5108n Ethernet Switch. It provides FCoE transit, but no native Fibre Channel ...
For detailed information, see the Dell EMC PowerEdge MX7000 documentation. ● The MX9116n Fabric Switching Engine is automatically placed in Full Switch and SmartFabric modes. The Expander Module offers: ○ Sixteen 25GE server-facing ports ○...Switch-Operating-Mode : Smart Fabric Mode To change the mode using the OS10 CLI. PowerEdge MX Ethernet I /O modules The Dell EMC PowerEdge MX7000 supports the following Ethernet modules: MX9116n Fabric Switching Engine, MX7116n Fabric Expander Module, and MX5108n Ethernet Switch. It provides FCoE transit, but no native Fibre Channel ...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 317
...that you can use to connect to servers with dual-port network interface cards (NICs). Changing operating modes To switch an MX9116n Fabric Switching Engine or MX5108n Ethernet Switch between operating modes (continued) Full Switch mode SmartFabric mode All configuration changes are deleted,... the changes you cannot assign interfaces to Full Switch mode, only the configuration changes you make to Full Switch mode. NOTE: Dell EMC Networking recommends disabling LLDP in SmartFabric mode (see Operating modes). SmartFabric to Full Switch mode When you change to them. ...
...that you can use to connect to servers with dual-port network interface cards (NICs). Changing operating modes To switch an MX9116n Fabric Switching Engine or MX5108n Ethernet Switch between operating modes (continued) Full Switch mode SmartFabric mode All configuration changes are deleted,... the changes you cannot assign interfaces to Full Switch mode, only the configuration changes you make to Full Switch mode. NOTE: Dell EMC Networking recommends disabling LLDP in SmartFabric mode (see Operating modes). SmartFabric to Full Switch mode When you change to them. ...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 324
... MX5108n Ethernet Switch, server-facing interfaces are internal and are enabled by default. In the output, a server-facing interface displays INTERNAL as Dell EMC Qualified true. NOTE: On the MX9116n Fabric Switching Engine, servers that have a dual-port NIC connect only to servers, use the show inventory media command. View QSFP28 breakout...
... MX5108n Ethernet Switch, server-facing interfaces are internal and are enabled by default. In the output, a server-facing interface displays INTERNAL as Dell EMC Qualified true. NOTE: On the MX9116n Fabric Switching Engine, servers that have a dual-port NIC connect only to servers, use the show inventory media command. View QSFP28 breakout...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 325
...1/1/8 down 0 auto A 1 - Eth 1/1/14 down 0 auto A 1 - Deployment instructions Dell EMC recommends: ● The replacement IOM must be up 25G A 1 - PowerEdge MX Ethernet I /O modules OS10 enables you must use a new MX9116n FSE as the faulty IOM. View internal Ethernet port-server connections - Eth 1/1/4 down 0 auto... MX5108n Ethernet Switch For information about the operating modes and chassis, see the Dell EMC PowerEdge MX7000 documentation. For example: If the faulty IOM model is MX9116n FSE, you to replace an Ethernet I/O module (IOM) that is not ...
...1/1/8 down 0 auto A 1 - Eth 1/1/14 down 0 auto A 1 - Deployment instructions Dell EMC recommends: ● The replacement IOM must be up 25G A 1 - PowerEdge MX Ethernet I /O modules OS10 enables you must use a new MX9116n FSE as the faulty IOM. View internal Ethernet port-server connections - Eth 1/1/4 down 0 auto... MX5108n Ethernet Switch For information about the operating modes and chassis, see the Dell EMC PowerEdge MX7000 documentation. For example: If the faulty IOM model is MX9116n FSE, you to replace an Ethernet I/O module (IOM) that is not ...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 328
... for each program are trademarks of the master IOM to log in to initiate the replacement workflow. 1. Use the IPv6 address of Dell Inc. admin@MX9116N-A2:~$ sfs_node_replace.py NewServiceTag oldServiceTag ○ NewServiceTag - Log in to the Linux shell from EXEC mode in the connected IOM. To... service tag of the system. Debian GNU/Linux comes with the Debian GNU/Linux system are free software; OS10# system bash admin@MX9116N-A2:~$ 2. Log in the IOM. This product is still using the IPv6 address displayed in to secure the system WARNING: Cluster manager...
... for each program are trademarks of the master IOM to log in to initiate the replacement workflow. 1. Use the IPv6 address of Dell Inc. admin@MX9116N-A2:~$ sfs_node_replace.py NewServiceTag oldServiceTag ○ NewServiceTag - Log in to the Linux shell from EXEC mode in the connected IOM. To... service tag of the system. Debian GNU/Linux comes with the Debian GNU/Linux system are free software; OS10# system bash admin@MX9116N-A2:~$ 2. Log in the IOM. This product is still using the IPv6 address displayed in to secure the system WARNING: Cluster manager...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 329
... the IOM hardware: 1. After ONIE uninstall process is mandatory to have console access to connect to mitigate any IOM replacement activity, contact Dell technical support. SmartFabric Services is an OS10 feature enabled on remote console to miss the output being shown in the master IOM: admin...@MX9116N-A2:~$ sfs_node_replace.py JDB1XC2 68RRNK2 Enter the Username for specified nodes. Output example when you use the module replacement command in the...
... the IOM hardware: 1. After ONIE uninstall process is mandatory to have console access to connect to mitigate any IOM replacement activity, contact Dell technical support. SmartFabric Services is an OS10 feature enabled on remote console to miss the output being shown in the master IOM: admin...@MX9116N-A2:~$ sfs_node_replace.py JDB1XC2 68RRNK2 Enter the Username for specified nodes. Output example when you use the module replacement command in the...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 562
...local, RPM, or ERPM. Mirror a member port of RPM. VLAN and destination VLAN. port on the same VLT device. port on the MX9116n and MX5108n with support for the port monitoring session. This command is configured, use local port the orphan port. Port monitoring commands description Configures... on a secondary VLT device through the orphan port. The packet analyzer connects to the ToR switch. RPM on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S). If the packet analyzer directly connects to the VLT peer The packet analyzer connects to...
...local, RPM, or ERPM. Mirror a member port of RPM. VLAN and destination VLAN. port on the same VLT device. port on the MX9116n and MX5108n with support for the port monitoring session. This command is configured, use local port the orphan port. Port monitoring commands description Configures... on a secondary VLT device through the orphan port. The packet analyzer connects to the ToR switch. RPM on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S). If the packet analyzer directly connects to the VLT peer The packet analyzer connects to...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 563
... 10.4.0(R3S). This command is introduced on the MX9116n and MX5108n with support for full-switch mode from the Dell EMC SmartFabric OS release 10.4.0(R3S). Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.5.1. Not configured MONITOR-... Enables flow-based monitoring. The monitoring session can be local or RPM. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.5.1. destination Sets the destination where monitored traffic is sent to the default.
... 10.4.0(R3S). This command is introduced on the MX9116n and MX5108n with support for full-switch mode from the Dell EMC SmartFabric OS release 10.4.0(R3S). Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.5.1. Not configured MONITOR-... Enables flow-based monitoring. The monitoring session can be local or RPM. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.5.1. destination Sets the destination where monitored traffic is sent to the default.
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 564
...the differentiated services code point (DSCP) value for full-switch mode from the Dell EMC SmartFabric OS release 10.5.1. ip Configures the IP time-to 63. This command is introduced on the MX9116n and MX5108n with support for the ERPM traffic. Example OS10(config)# monitor session...MONITOR-SESSION (ERPM) The no version of this command removes the monitor session. This command is introduced on the MX9116n and MX5108n with port monitoring. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S).
...the differentiated services code point (DSCP) value for full-switch mode from the Dell EMC SmartFabric OS release 10.5.1. ip Configures the IP time-to 63. This command is introduced on the MX9116n and MX5108n with support for the ERPM traffic. Example OS10(config)# monitor session...MONITOR-SESSION (ERPM) The no version of this command removes the monitor session. This command is introduced on the MX9116n and MX5108n with port monitoring. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S).
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 565
... ethernet1/1/2 remote-ip both port N/A N/A 0 255 35 Destination is enabled. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 1 Example (specific session) OS10# show monitor session 1 S.Id Source Destination Dir Mode Source IP Dest... Information All EXEC In the State field, true indicates that hardware resour This command is introduced on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S). Syntax Parameters Default Command Mode Usage Information shut None Disabled MONITOR-SESSION The...
... ethernet1/1/2 remote-ip both port N/A N/A 0 255 35 Destination is enabled. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 1 Example (specific session) OS10# show monitor session 1 S.Id Source Destination Dir Mode Source IP Dest... Information All EXEC In the State field, true indicates that hardware resour This command is introduced on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S). Syntax Parameters Default Command Mode Usage Information shut None Disabled MONITOR-SESSION The...
EMC SmartFabric OS10 User Guide Release 10.5.1
Page 566
...1 to 4093. ● both-Monitor both receiving and transmitting packets. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S). Default Command Mode Usage Information Not configured MONITOR-SESSION This command is introduced on ...the MX9116n and MX5108n with support for full-switch mode from the Dell EMC SmartFabric OS release 10.5.1. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S). The...
...1 to 4093. ● both-Monitor both receiving and transmitting packets. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S). Default Command Mode Usage Information Not configured MONITOR-SESSION This command is introduced on ...the MX9116n and MX5108n with support for full-switch mode from the Dell EMC SmartFabric OS release 10.5.1. Also supported in SmartFabric Services mode on the MX9116n and MX5108n from the Dell EMC SmartFabric OS release 10.4.0(R3S). The...