User Guide
Page 5
...Use only with the listed ITE: Adaptec RAID 5085/Adaptec RAID 5405/Adaptec RAID 5445/ Adaptec RAID 5805/ Adaptec RAID 5405Z/Adaptec RAID 5805Z/Adaptec RAID 5445Z/ Adaptec RAID 51245/Adaptec RAID 51645/Adaptec RAID 52445/ Adaptec RAID 2045/Adaptec RAID 2405 Tested to Comply With FCC...and receiver. ■ Connect the equipment to an outlet on VCCI (Voluntary Control Council for a Class B digital device, pursuant to the Australian/New Zealand... to ensure compliance of this unit to the specified limits of used batteries according to the instructions. Cet appareil numérique de la classe...
...Use only with the listed ITE: Adaptec RAID 5085/Adaptec RAID 5405/Adaptec RAID 5445/ Adaptec RAID 5805/ Adaptec RAID 5405Z/Adaptec RAID 5805Z/Adaptec RAID 5445Z/ Adaptec RAID 51245/Adaptec RAID 51645/Adaptec RAID 52445/ Adaptec RAID 2045/Adaptec RAID 2405 Tested to Comply With FCC...and receiver. ■ Connect the equipment to an outlet on VCCI (Voluntary Control Council for a Class B digital device, pursuant to the Australian/New Zealand... to ensure compliance of this unit to the specified limits of used batteries according to the instructions. Cet appareil numérique de la classe...
User Guide
Page 6
... Your RAID Controller Standard RAID Controller Features 16 Array-level Features 16 Advanced Data Protection Suite 16 Adding a Battery Backup Module 17 Upgrading the Controller Firmware 17 About the Adaptec RAID 5085 18 About the Adaptec RAID 5405 19 About the Adaptec RAID 5445 20 About the Adaptec RAID 5805 21 About the Adaptec RAID 51245 22 About the Adaptec RAID 51645 23 About the Adaptec RAID 52445 24 About the Adaptec RAID...
... Your RAID Controller Standard RAID Controller Features 16 Array-level Features 16 Advanced Data Protection Suite 16 Adding a Battery Backup Module 17 Upgrading the Controller Firmware 17 About the Adaptec RAID 5085 18 About the Adaptec RAID 5405 19 About the Adaptec RAID 5445 20 About the Adaptec RAID 5805 21 About the Adaptec RAID 51245 22 About the Adaptec RAID 51645 23 About the Adaptec RAID 52445 24 About the Adaptec RAID...
User Guide
Page 15
About Your RAID Controller 3 In this chapter... Standard RAID Controller Features 16 Adding a Battery Backup Module 17 Upgrading the Controller Firmware 17 About the Adaptec RAID 5085 18 About the Adaptec RAID 5405 19 About the Adaptec RAID 5445 20 About the Adaptec RAID 5805 21 About the Adaptec RAID 51245 22 About the Adaptec RAID 51645 23 About the Adaptec RAID 52445 24 About the Adaptec RAID 5405Z 25 About the Adaptec RAID 5445Z 26...
About Your RAID Controller 3 In this chapter... Standard RAID Controller Features 16 Adding a Battery Backup Module 17 Upgrading the Controller Firmware 17 About the Adaptec RAID 5085 18 About the Adaptec RAID 5405 19 About the Adaptec RAID 5445 20 About the Adaptec RAID 5805 21 About the Adaptec RAID 51245 22 About the Adaptec RAID 51645 23 About the Adaptec RAID 52445 24 About the Adaptec RAID 5405Z 25 About the Adaptec RAID 5445Z 26...
User Guide
Page 16
...the most efficient order for optimum performance ● Support for disk drive enclosures with SES2 enclosure management hardware ● Support for a battery backup module (see page 17) ● Support for a zero maintenance cache protection module (see page 36) ● Support for...; Support for remote analysis ("call home") Array-level Features Note: Not all features are supported by Adaptec 5-Series controllers only. Chapter 3: About Your RAID Controller ● 16 Standard RAID Controller Features ● Support for SAS disk drives, SATA/SATA II disk drives, SATA Solid State Drives ...
...the most efficient order for optimum performance ● Support for disk drive enclosures with SES2 enclosure management hardware ● Support for a battery backup module (see page 17) ● Support for a zero maintenance cache protection module (see page 36) ● Support for...; Support for remote analysis ("call home") Array-level Features Note: Not all features are supported by Adaptec 5-Series controllers only. Chapter 3: About Your RAID Controller ● 16 Standard RAID Controller Features ● Support for SAS disk drives, SATA/SATA II disk drives, SATA Solid State Drives ...
User Guide
Page 17
...; Striped Mirror (RAID 1E)-A RAID 1 Enhanced array is similar to a RAID 1 array except that data is similar to the Adaptec Web site at www.adaptec.com. Upgrading the Controller Firmware To upgrade the firmware on your Adaptec RAID controller. RAID Controller Adaptec RAID 5085/Adaptec RAID 5405/Adaptec RAID 5445/Adaptec RAID 5805/ Adaptec 51245/Adaptec 51645/Adaptec 52445 Battery Model Adaptec Battery Module 800 Adaptec Battery Module 800T To purchase a battery backup module, refer to a RAID 50 array except...
...; Striped Mirror (RAID 1E)-A RAID 1 Enhanced array is similar to a RAID 1 array except that data is similar to the Adaptec Web site at www.adaptec.com. Upgrading the Controller Firmware To upgrade the firmware on your Adaptec RAID controller. RAID Controller Adaptec RAID 5085/Adaptec RAID 5405/Adaptec RAID 5445/Adaptec RAID 5805/ Adaptec 51245/Adaptec 51645/Adaptec 52445 Battery Model Adaptec Battery Module 800 Adaptec Battery Module 800T To purchase a battery backup module, refer to a RAID 50 array except...
User Guide
Page 18
Chapter 3: About Your RAID Controller ● 18 About the Adaptec RAID 5085 The Adaptec RAID 5085 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Output) Yes Adaptec Battery Module 800/800T (sold separately-see page 17) Alarm Aggregate Activity Mode 0 Flash connector Activity LEDs Diagnostic LEDs Audible Alarm Drive Activity LED connectors for ...
Chapter 3: About Your RAID Controller ● 18 About the Adaptec RAID 5085 The Adaptec RAID 5085 is a SAS RAID controller with expanders) I2C and SGPIO (Serial General Purpose Output) Yes Adaptec Battery Module 800/800T (sold separately-see page 17) Alarm Aggregate Activity Mode 0 Flash connector Activity LEDs Diagnostic LEDs Audible Alarm Drive Activity LED connectors for ...
User Guide
Page 19
...PCIe bus width PCIe bus speed Phys (Unified Serial Ports) Standard cache Connectors, internal Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Low-profile MD2 PCIe x8 2.5 Gb/s 4 256 MB DDR2 1 mini-SAS x4 (SFF-8087) 4 direct-attached (or...Diagnostic LEDs Internal mini-SAS connector CN0 Status CN0 PCIe x8 connector Mounting bracket Ext. Chapter 3: About Your RAID Controller ● 19 About the Adaptec RAID 5405 The Adaptec RAID 5405 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17)
...PCIe bus width PCIe bus speed Phys (Unified Serial Ports) Standard cache Connectors, internal Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Low-profile MD2 PCIe x8 2.5 Gb/s 4 256 MB DDR2 1 mini-SAS x4 (SFF-8087) 4 direct-attached (or...Diagnostic LEDs Internal mini-SAS connector CN0 Status CN0 PCIe x8 connector Mounting bracket Ext. Chapter 3: About Your RAID Controller ● 19 About the Adaptec RAID 5405 The Adaptec RAID 5405 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17)
User Guide
Page 20
...-8088) external 8 direct-attached (or up to 256 with these features: Drive Activity CN1/CN0 Status CN1/CN0 Mode 0 Flash connector Ext. Chapter 3: About Your RAID Controller ● 20 About the Adaptec RAID 5445 The Adaptec RAID 5445 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17)
...-8088) external 8 direct-attached (or up to 256 with these features: Drive Activity CN1/CN0 Status CN1/CN0 Mode 0 Flash connector Ext. Chapter 3: About Your RAID Controller ● 20 About the Adaptec RAID 5445 The Adaptec RAID 5445 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17)
User Guide
Page 21
Chapter 3: About Your RAID Controller ● 21 About the Adaptec RAID 5805 The Adaptec RAID 5805 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17) Alarm connector Form Factor Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) Standard ...
Chapter 3: About Your RAID Controller ● 21 About the Adaptec RAID 5805 The Adaptec RAID 5805 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17) Alarm connector Form Factor Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) Standard ...
User Guide
Page 22
Chapter 3: About Your RAID Controller ● 22 About the Adaptec RAID 51245 The Adaptec RAID 51245 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17) Alarm Aggregate Activity Form Factor Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) ...
Chapter 3: About Your RAID Controller ● 22 About the Adaptec RAID 51245 The Adaptec RAID 51245 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17) Alarm Aggregate Activity Form Factor Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) ...
User Guide
Page 23
Chapter 3: About Your RAID Controller ● 23 About the Adaptec RAID 51645 The Adaptec RAID 51645 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17) Alarm Aggregate Activity Form Factor Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) ...
Chapter 3: About Your RAID Controller ● 23 About the Adaptec RAID 51645 The Adaptec RAID 51645 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17) Alarm Aggregate Activity Form Factor Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) ...
User Guide
Page 24
... PCIe bus speed Phys (Unified Serial Ports) Standard cache Connectors, Internal Connectors, Exteneral Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Full Height, Half Length PCIe x8 2.5 Gb/s 28 512 MB DDR2 6 mini-SAS x4 (SFF-8087) 1 mini-... mini-SAS connector CN2 CN3 6 internal mini-SAS connectors ABM-800 connector Reserved Ext. Chapter 3: About Your RAID Controller ● 24 About the Adaptec RAID 52445 The Adaptec RAID 52445 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17)
... PCIe bus speed Phys (Unified Serial Ports) Standard cache Connectors, Internal Connectors, Exteneral Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Full Height, Half Length PCIe x8 2.5 Gb/s 28 512 MB DDR2 6 mini-SAS x4 (SFF-8087) 1 mini-... mini-SAS connector CN2 CN3 6 internal mini-SAS connectors ABM-800 connector Reserved Ext. Chapter 3: About Your RAID Controller ● 24 About the Adaptec RAID 52445 The Adaptec RAID 52445 is a SAS RAID controller with expanders) I2C and SGPIO Yes Adaptec Battery Module 800/800T (sold separately-see page 17)
User Guide
Page 28
Chapter 3: About Your RAID Controller ● 28 About the Adaptec RAID 2045 The Adaptec RAID 2045 is a SAS RAID controller with these features: Aggregate Activity Mode 0 Flash connector CN1 1 external ...miniSAS connector Mounting bracket PCIe x8 connector Form Factor Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) Standard cache Connectors, external Maximum number of disk drives Enclosure Support Onboard speaker Battery...
Chapter 3: About Your RAID Controller ● 28 About the Adaptec RAID 2045 The Adaptec RAID 2045 is a SAS RAID controller with these features: Aggregate Activity Mode 0 Flash connector CN1 1 external ...miniSAS connector Mounting bracket PCIe x8 connector Form Factor Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) Standard cache Connectors, external Maximum number of disk drives Enclosure Support Onboard speaker Battery...
User Guide
Page 29
Chapter 3: About Your RAID Controller ● 29 About the Adaptec RAID 2405 The Adaptec RAID 2405 is a SAS RAID controller with these features: Activity connector for CN0 Aggregate Activity Mode 0 Flash connector Internal mini-SAS connector CN0 Mounting bracket I2C, CN0 PCIe x8 connector... Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) Standard cache Connectors, internal Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Low-profile MD2 PCIe x8 2.5 Gb/s 4 128 MB DDR2 1 mini-SAS x4 (SFF-8087) 4 direct-attached (or up to 128 with ...
Chapter 3: About Your RAID Controller ● 29 About the Adaptec RAID 2405 The Adaptec RAID 2405 is a SAS RAID controller with these features: Activity connector for CN0 Aggregate Activity Mode 0 Flash connector Internal mini-SAS connector CN0 Mounting bracket I2C, CN0 PCIe x8 connector... Bus compatibility PCIe bus width PCIe bus speed Phys (Unified Serial Ports) Standard cache Connectors, internal Maximum number of disk drives Enclosure Support Onboard speaker Battery Backup Module Low-profile MD2 PCIe x8 2.5 Gb/s 4 128 MB DDR2 1 mini-SAS x4 (SFF-8087) 4 direct-attached (or up to 128 with ...
User Guide
Page 37
... 5 Attach the zero maintenance cap card (ZMM-100CC) to the RAID controller by inserting the connector into place. When installed properly, the RAID controller should appear level with Zero Maintenance Cache Protection Warning: Do not attempt to connect a Battery Backup Module (see About Your RAID Controller on page 15. 7 Prepare and install your internal disk drives, ...drives, close your computer cabinet, reattach the power cord, then continue with Connecting External Devices on the chassis or in the system to an Adaptec RAID controller with your computer and disconnect the power cord.
... 5 Attach the zero maintenance cap card (ZMM-100CC) to the RAID controller by inserting the connector into place. When installed properly, the RAID controller should appear level with Zero Maintenance Cache Protection Warning: Do not attempt to connect a Battery Backup Module (see About Your RAID Controller on page 15. 7 Prepare and install your internal disk drives, ...drives, close your computer cabinet, reattach the power cord, then continue with Connecting External Devices on the chassis or in the system to an Adaptec RAID controller with your computer and disconnect the power cord.
User Guide
Page 129
... 129 Environmental Specifications Note: Adaptec RAID controllers require adequate airflow to -peak (max) 3.3 V ± 9%, 12 V ± 8% Current Requirements Adaptec Model Adaptec RAID 5085 Adaptec RAID 5805 Adaptec RAID 5405 Adaptec RAID 5445 Adaptec RAID 5805Z Adaptec RAID 5405Z Adaptec RAID 5445Z Adaptec RAID 51245 Adaptec RAID 51645 Adaptec RAID 52445 Adaptec RAID 2045 Adaptec RAID 2405 Typical Current 0.45 A...Ambient temperature with forced airflow Ambient temperature without forced airflow Ambient temperature with Battery Backup Unit (BBU) Relative humidity Altitude 0 °C to 55 ...
... 129 Environmental Specifications Note: Adaptec RAID controllers require adequate airflow to -peak (max) 3.3 V ± 9%, 12 V ± 8% Current Requirements Adaptec Model Adaptec RAID 5085 Adaptec RAID 5805 Adaptec RAID 5405 Adaptec RAID 5445 Adaptec RAID 5805Z Adaptec RAID 5405Z Adaptec RAID 5445Z Adaptec RAID 51245 Adaptec RAID 51645 Adaptec RAID 52445 Adaptec RAID 2045 Adaptec RAID 2405 Typical Current 0.45 A...Ambient temperature with forced airflow Ambient temperature without forced airflow Ambient temperature with Battery Backup Unit (BBU) Relative humidity Altitude 0 °C to 55 ...
User Guide
Page 130
... RAID 5 78 RAID 50 80 RAID 5EE 79 RAID 6 81 RAID 60 81 arrays (bootable) 43 audible alarm 63 automatic failover 16 Automatic Failover setting 89 B backplane connections 39, 71 battery backup module 17 batteryless backup 36, 37 BBU 17 boards. See ARCCONF Adaptec Storage Manager 60 creating arrays 46 installing 60 adapters. See controllers boot controller 44 See controllers...
... RAID 5 78 RAID 50 80 RAID 5EE 79 RAID 6 81 RAID 60 81 arrays (bootable) 43 audible alarm 63 automatic failover 16 Automatic Failover setting 89 B backplane connections 39, 71 battery backup module 17 batteryless backup 36, 37 BBU 17 boards. See ARCCONF Adaptec Storage Manager 60 creating arrays 46 installing 60 adapters. See controllers boot controller 44 See controllers...