AL1911 Service Guide
Page 1
...36 8.2 Package Drop Specification ...36 8.3 Dimension Size and Weight ...37 8.4 Gap Spec...37 8.5 Tilt Base Rotation...39 8.6 Swivel Base Rotation ...39 8.7 Plastic Material ...40 8.8 GAP Spec...40 9. ELECTRICAL REQUIREMENTS...4 2.1 Standard Test Conditions ...4 2.2 LCD monitor General specification......21 3.6 Connector pin assignment ...21 4. TROUBLESHOOTING ...30 7.1 Main Procedure...30 8. INTRODUCTION...3 1.1 Scope ...3 1.2 Description...3 2. AL1911 TFT LCD MONITOR CONTENTS 1. Power Line Transient Test (IEC 61000-4-4 Fast Transients/Burst 40 9.1 Peak Voltage ...40 9.2 Polarity ...40...
...36 8.2 Package Drop Specification ...36 8.3 Dimension Size and Weight ...37 8.4 Gap Spec...37 8.5 Tilt Base Rotation...39 8.6 Swivel Base Rotation ...39 8.7 Plastic Material ...40 8.8 GAP Spec...40 9. ELECTRICAL REQUIREMENTS...4 2.1 Standard Test Conditions ...4 2.2 LCD monitor General specification......21 3.6 Connector pin assignment ...21 4. TROUBLESHOOTING ...30 7.1 Main Procedure...30 8. INTRODUCTION...3 1.1 Scope ...3 1.2 Description...3 2. AL1911 TFT LCD MONITOR CONTENTS 1. Power Line Transient Test (IEC 61000-4-4 Fast Transients/Burst 40 9.1 Peak Voltage ...40 9.2 Polarity ...40...
AL1911 Service Guide
Page 18
... - - Max. 5 - 500 800 - 6 d B Volume Max.,load 4 ? - +10d B Volume Max.,load 4 ? - -40dB Volume Max.,load 4 ? 1% except speakers distortion - -30dB Volume Max.,load 4 ? - 1W Volume Max.,load 4 ? - - Spec. Comment Typ. 2.8 Plug & Play(EDID) The monitor will be capable of sending a VESA standardized EDID file through the DDC (pins 12, 15 of the VGA...
... - - Max. 5 - 500 800 - 6 d B Volume Max.,load 4 ? - +10d B Volume Max.,load 4 ? - -40dB Volume Max.,load 4 ? 1% except speakers distortion - -30dB Volume Max.,load 4 ? - 1W Volume Max.,load 4 ? - - Spec. Comment Typ. 2.8 Plug & Play(EDID) The monitor will be capable of sending a VESA standardized EDID file through the DDC (pins 12, 15 of the VGA...
AL1911 Service Guide
Page 36
...: 120 G peak, half sine pulse, 2 ms pulse duration. Testing shall consist of one hour for a total of drop heights for monitor product Product Weight height Specs Random Vibration: 0.008 G2/Hz, 10 to 500 Hz, nominal 2 GRMS. The test shall be for one shock in each direction in each of the...
...: 120 G peak, half sine pulse, 2 ms pulse duration. Testing shall consist of one hour for a total of drop heights for monitor product Product Weight height Specs Random Vibration: 0.008 G2/Hz, 10 to 500 Hz, nominal 2 GRMS. The test shall be for one shock in each direction in each of the...
AL1911 Service Guide
Page 37
Back Cover & Bezel Gap 0.8 mm ≤ A ≤ 1.2 mm Back Cover & Bezel Alignment 0 mm ≤ D ≤ 0.8 mm Back Cover & Cable Cover Gap 0.8 mm ≤ B ≤ 1.2 mm 37 8.3 Dimension Size and Weight Dimension size Net Weight Gross Weight 433 (W) x 447 (H) x 235 (D) 6.5Kg 9 Kg 8.4 Gap Spec. 8.4.1 The step between front bezel and back cover shall be within specification.
Back Cover & Bezel Gap 0.8 mm ≤ A ≤ 1.2 mm Back Cover & Bezel Alignment 0 mm ≤ D ≤ 0.8 mm Back Cover & Cable Cover Gap 0.8 mm ≤ B ≤ 1.2 mm 37 8.3 Dimension Size and Weight Dimension size Net Weight Gross Weight 433 (W) x 447 (H) x 235 (D) 6.5Kg 9 Kg 8.4 Gap Spec. 8.4.1 The step between front bezel and back cover shall be within specification.
AL1911 Service Guide
Page 40
V0 The others ABS 94 HB 8.8 GAP Spec. Gap between panel with bezel is base on operating with 50Ω load. 9.1 Peak Voltage: 2 KV (applies the Level 3 typical Industrial Environment" of IEC 61000-4-4) 9.2 ...
V0 The others ABS 94 HB 8.8 GAP Spec. Gap between panel with bezel is base on operating with 50Ω load. 9.1 Peak Voltage: 2 KV (applies the Level 3 typical Industrial Environment" of IEC 61000-4-4) 9.2 ...