Get support for KitchenAid KDRS483VSS - 48

KitchenAid KDRS483VSS Support Question

KitchenAid KDRS483VSS Support Question

Find answers below for this question about KitchenAid KDRS483VSS - 48" Commercial Dual Fuel Range.
Need a KitchenAid KDRS483VSS manual? We have 3 online manuals for this item!
Question posted by Anonymous-123541 on October 29th, 2013

Inlet Gas Pressure?

What should the inlet gas pressure be?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related KitchenAid KDRS483VSS Manual Pages

Dimension Guide - Page 1

...of the "Location Requirements" section. 30", 36", and 48" Professional Dual Fuel Convection Ranges PRODUCT MODEL NUMBERS KDRS407VSS KDRS462VSS KDRS463VSS KDRS467VSS KDRS483VSS KDRU707VSS GAS REQUIREMENTS KDRU763VSS KDRU767VSS KDRU783VSS Type of Gas Natural Gas: This range is design-certified by a qualified service technician. With LP gas, piping or tubing size can be used . Refer to...
Dimension Guide - Page 2

C D ** B C E D O*** F A F H I J Electrical installation K area* E I G L N M J Gas installation area 48" (121.9 cm) models NOTE: The following illustration is for dimensional clearances above the range, follow the range hood installation instructions for dimension planning purposes only, and the locations and appearances of the features shown may not match those of your model....
Installation Guide - Page 4

...; LP orifice package (W10221288) ■ Conversion label (W10221320) NOTE: The cooktop is manufactured for use with a backguard if installing at zero clearance to wall behind range. See "Install Anti-Tip Bracket" section. ■ Gas pressure regulator ■ 48" (121.9 cm) Adjustable Backguard Order Part Number 8284755 ■ 9" (22.9 cm) Backguard for 30" (76.2 cm...
Installation Guide - Page 5

...) Backguard with Shelf for 48" (121.9 cm) Ranges Order Part Number W10225948 To order, see the "Assistance or Service" section of combustion and ventilation air. ■ It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. Check local codes and consult gas supplier. High Altitude Conversion...
Installation Guide - Page 6

...Cabinet Dimensions Cabinet opening dimensions shown are for dimensional clearances above the range, follow the range hood or hood liner installation instructions for 25" (64 cm) ... (76.2 cm) models 28" (71.1 cm) on 36" (91.4 cm) models 40" (101.6 cm) on 48" (121.9 cm) models I G L N M J Gas installation area A. 18" (45.7 cm) upper cabinet to countertop B. 30" (76.2 cm) model: 30" (76.2...
Installation Guide - Page 7

... (91.4 cm) 12.6 - 18.5 kW 50 48" (121.9 cm) *The NEC calculated load is less than 40 psi (276 kPa): ■ Check to setting the range in the reverse osmosis system is recommended. ■ ...Water Supply IMPORTANT: The pressure of the water supply coming out of a reverse osmosis system going to the water inlet valve of the range needs to allow for it here. ■ Range must be used , ...
Installation Guide - Page 8

... on 30" (76.2 cm) and 36" (91.4 cm) ranges and a 50-amp minimum circuit protections is required on 48" (121.9 cm) ranges, fused on the appliance end must be plugged into a standard 14... terminating in accordance with local codes. Canada Only WARNING Electrical Shock Hazard Electrically ground range. or 50-amp range power supply cord (pigtail). Be sure that the ground path and wire gauge are...
Installation Guide - Page 9

... valve should be in a location that resist the action of the inlet to the range. The valve is needed for use with American National Standard, National Fuel Gas Code ANSI Z223.1/NFPA 54 - B A C A. Examples of Gas Natural Gas: This range is design-certified by a qualified service technician. Usually, LP gas suppliers determine the size and materials used . To...
Installation Guide - Page 10

... pressure: 14" (35.6 cm) WCP LP Gas: Minimum pressure: 11" (27.9 cm) WCP Maximum pressure: 14" (35.6 cm) WCP Contact local gas supplier if you are for elevations up about the inlet pressure. Altitude Input ratings shown on the model/serial rating plate are not sure about 3" (8.0 cm) and move and install range. INSTALLATION INSTRUCTIONS Unpack Range WARNING 3. For 48...
Installation Guide - Page 11

... bracket must be installed on the right side of the determined mounting method. Measurement B: 30" (76.2 cm) ranges: 11⁵⁄₈" (29.5 cm) 36" (91.4 cm) ranges: 14⁵⁄₈" (37.1 cm) 48" (121.9 cm) ranges: 20⁵⁄₈" (52.4 cm) Wall Mounting B A. #12 x 1⁵⁄₈" screws B. Longer screws are...
Installation Guide - Page 15

... is not kinked. Oven copper tubing F. Range front 6. C. Flexible connector HG F E. Open the manual shutoff valve in water filter kit) E. Flexible codes approved water supply line from gas supply pipe to LP, have ½" male pipe thread) D. Check that connector is parallel to the gas shutoff valve. Gas pressure regulator B. Adapter (must have a qualified person...
Installation Guide - Page 18

...the fuse has not blown. ■ Check that the gas shutoff valves are set to the "open or the control... A. Put a control knob onto the valve stem of the range that the range is lit, it drop forward into the notched console brackets on...5. The first time a burner is plugged in place of air in place. Dual Flame Burner A B 4. Lower (simmer) flame Single Flame Burner To Adjust Flame...
Installation Guide - Page 19

... technician. 4. NOTE: When you purchased your tools. 3. Reinstall Kickplate 1. Dual flame burner adjustment screw (on the control console and set the clock and other burners that all parts are converting to see which step was skipped. 2. Lift up against front of the range. 3. A A. Replace burner grates. 20. A D A. See the Use and Care...
Installation Guide - Page 20

...is moved. Reinstall the cap onto the regulator. The inlet pressure to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column...range and be checked at test pressures equal to remove the burner head of the spring retainer. The regulator must be done by pushing against the flat side of the large dual burners. 20 Test the gas pressure regulator and gas...
Installation Guide - Page 22

... C. Test the gas pressure regulator and gas supply line. The regulator must be checked at the spring retainer to remove the burner head of ½ psi (3.5 kPa). The inlet pressure to the closed position) C. Unplug range or disconnect power. NOTE: A ⁷⁄₈" socket must be used to locate the "LP" or "NAT" position. A B A Large Dual Burner...
Use & Care Guide - Page 7

...elements with handle Optional stainless steel knobs C A A. The range you have some models) B. Stainless steel panels E. Dual fan true convection oven I Optional grill cover Optional wok ...viewing window L. Commercial style die cast metal control knobs M. CleanBake™ hidden element E. Island trim D. T.H.E.™ 18" (45.7 cm) true convection oven [48" (121.9 cm) range only] H....
Use & Care Guide - Page 15

..., an invalid pad was pressed. Convection oven settings C. Off J. Oven settings D. Right oven off ) 48" (121.9 cm) Range Control Panel C D EF G H I . Cook time (length of your entry. When the oven ... press the desired function. ELECTRONIC OVEN CONTROLS 30" (76.2 cm) and 36" (91.4 cm) Range Control Panel C D E F G CLEAN TIME NIGHT F PROBE TEMP LIGHT MIN HR SEC MIN ...
Use & Care Guide - Page 27

...cooled down. Oven Lights The oven lights are 120-volt, 25-watt maximum halogen bulbs. On 48" (121.9 cm) ranges, both sides. Cleaning Method: ■ Hot, soapy water and/or nylon scrub pad ■.... When the oven door is not suggested to move and install oven doors. For normal range use oven cleaners, metal brushes, abrasive scouring pads or other injury. Continue to push the...
Use & Care Guide - Page 29

... your appliance. To order accessories, call . See "Timed/Delay Cooking" section. ■ On 48" (121.9 cm) ranges, is self-cleaning, the other oven cannot be set ? Oven cooking results not what expected &#... Options." Cooktop Cleaner Order Part Number 31464 Cooktop Protectant Order Part Number 31463 Gas Grate/Drip Pan Cleaner Order Part Number 31617 All-Purpose Appliance Cleaner Order Part Number...
Use & Care Guide - Page 30

...element ■ Solid state touch control system parts ■ Gas burners 30 Service must be provided by a KitchenAid designated ...warranty service, anywhere in Canada. KITCHENAID® DUAL FUEL RANGE WARRANTY LIMITED WARRANTY For one year from the ...to instructions attached to KitchenAid Canada with Shelf for 48" (121.9 cm) Ranges and Cooktops Order Part Number W10225948 KitchenAid® ...

KitchenAid Knowledge Base Results

We have determined that the information below may contain an answer to this question. If you find an answer, please remember to return to this page and add it here using the "I KNOW THE ANSWER!" button above. It's that easy to earn points!

  • Water supply hookup - French door with exterior dispenser
    ...hookup - If the water pressure to the reverse osmosis system is your refrigerator has a water filter, it is used in many areas due to the water inlet valve of 4 gal. (... Your Email Your Name Water supply hookup - This will go. Allow 24 hours to your water pressure, call a licensed, qualified plumber. Bottom freezer/French door refrigerators Water dispenser not working - See ...
  • Connecting the water supply
    ...refrigerator. Reverse-osmosis water supply : The pressure of the water supply coming out of a reverse-osmosis system going to the water inlet valve of copper tubing are cut square. ... be a minimum of refrigerator to the water pipe. Add 7' (2.1 m) to your water pressure, call a licensed, qualified plumber. Connect to refrigerator and check for leaks. Correct any leaks...
  • Water supply hookup - Side by side refrigerator
    ... the refrigerator to  avoid operation without water. Additional flushing may reduce the water pressure when used in some models; Side by hand. Share Delicious Digg Facebook Reddit StumbleUpon ... seconds off) until water begins to the valve inlet using the water supply line, if possible. As air is your water supply, the water pressure to the system needs to identify the ...

Similar Questions

All Four Burners Lost The Spark All At Once. Suspect The Spark Module. Which
suspect the spark module. Which part is it for my kitchenaid KDSS907SSS DUAL FUEL range. Also. I app...
(Posted by Andrewenman 6 years ago)
Kitchenaid Kdss907sss - 30' Slide-in Dual Fuel Range Position Of Range
Should the back of the 30" slide-in range touch the back wall?
(Posted by patriciainsf 11 years ago)
Has Anyone Had Any Problems With This Kitchenaid Duel Fuel Range?
The touch panel is on the same plane as the cooking surface, so spills will get on it. I can run my ...
(Posted by dcarlick 12 years ago)
Range Problem
the igniters on my new kdrs483vss operate constantly when the range is plugged in. Any ideas?
(Posted by brockdupont 12 years ago)
Ask a New Question
Use the box below to post a new question about this KitchenAid product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

KitchenAid Manuals

Find free KitchenAid KDRS483VSS - 48inch Commercial Dual Fuel Range manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

KitchenAid Reviews

View thousands of KitchenAid user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete KitchenAid customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed KitchenAid customer service rankings, employee comments and much more from our sister site.

KitchenAid Recalls

Find comprehensive KitchenAid recall information updated hourly on RecallOwl.com.