Get support for HP MSA70

HP MSA70 Support Question

HP MSA70 Support Question

Find answers below for this question about HP MSA70.
Need a HP MSA70 manual? We have 14 online manuals for this item!
Question posted by mguely on September 29th, 2014

Connect To A Virtual Server

How can I connect a HP MSA70 to a virtual server??

Current Answers

Answer #1: Posted by TommyKervz on September 29th, 2014 7:16 PM
This answer was accepted by the poster of the original question.
TommyKervz

Member since:
January 10th, 2013

Points: 17,776,813
1,100
points
Download this Document below and follow the connection instructions on it

http://community.hpe.com/t5/errors/errorpage


Hope that is helpful.
Kervz at www.satechhelp.co.za

Related HP MSA70 Manual Pages

HP StorageWorks 70 Modular Smart Array Enclosure maintenance and service guide (434895-003, March 2007) - Page 25

... servers, ensure that the server to which the MSA70 is connected is powered up. Taking this precaution ensures that the servers, during their discovery, see the enclosure as failed when the server is the first unit to be powered down the enclosure. This ensures that the system does not erroneously mark the drives as an operational device...
HP StorageWorks 70 Modular Smart Array Enclosure maintenance and service guide (434895-003, March 2007) - Page 33

...replacement component as quickly as possible. Power down any SAS cables connected to the I /O status LED: Green = System activity ...MSA70 may overheat and automatically shut down the enclosure: a. d. c. Wait for errors. Verifying component failure Use the following methods to amber. See the server documentation. Removing a component impacts the airflow and cooling ability of the device...
HP StorageWorks 70 Modular Smart Array Enclosure maintenance and service guide (434895-003, March 2007) - Page 51

...following to secure it in the chassis and connect the cables. 2. If the internal temperature exceeds acceptable limits, the MSA70 may overheat and automatically shut down to verify...fans, and power supplies. 3. Removing a component impacts the airflow and cooling ability of the device. Installing the midplane To install the midplane, reverse the removal procedure: 1. To avoid possible ...
HP StorageWorks 70 Modular Smart Array Enclosure setup poster (434894-001, February 2007) - Page 1

...through the holes without notice. Use the thumbscrews on the device shows which class (A or B) the equipment falls into the...MSA70 Enclosure • Rack mounting hardware kit • Power cords (2) • SAS cable • Documentation kit Installing options Install any reason. The only warranties for the person who installs, administers, and troubleshoots servers and storage systems. HP...
HP StorageWorks 70 Modular Smart Array Enclosure setup poster (434894-001, February 2007) - Page 2

.... b. Cabling guidelines • Always use supported SAS cables with the MSA70 Enclosure installed. To reduce the risk of supported cables, see the HP website: http://h18004.www1.hp.com/support/files/storage/us/index .html. Powering up IMPORTANT: Always power up the servers. If you have the latest firmware. See "Choosing a configuration" on this product...
HP StorageWorks 70 Modular Smart Array Enclosure User Guide (434893-003, February 2010) - Page 3

...14 Electrical grounding requirements 15 Rack planning resources ...15 Rack warnings ...15 MSA70 shipping contents ...16 Rack mounting hardware kit contents 16 Converting rails for ...server ...22 Connecting SAS cables and power cords 23 Cabling best practices ...23 Connecting SAS cables to the server or controller enclosure 23 Connecting SAS cables to additional disk enclosures 24 Connecting...
HP StorageWorks 70 Modular Smart Array Enclosure User Guide (434893-003, February 2010) - Page 11

Because dual domain deployments provide two paths to the storage, access is then connected to the server or network. For more information, see the QuickSpecs for the disk enclosure. • Controller enclosure attached (single or dual domain) In a controller enclosure attached deployment, the disk enclosure is connected to a controller card installed in the disk enclosure...
HP StorageWorks 70 Modular Smart Array Enclosure User Guide (434893-003, February 2010) - Page 26

... in the configuration). IMPORTANT: If power is applied to the server before powering on . • Connect the SAS cables and power cords to the disk enclosures, start the operating system, and log on the server, the monitor might not properly discover the storage and may erroneously mark the drives as administrator. Power on (or...
HP StorageWorks 60/70 Modular Smart Array Enclosure Firmware v2.28 Release Notes (536920-006, May 2011) - Page 3

... version TS230 and later TS220, TS210, TS201, TS200 and earlier M112 and later M111 and earlier All MSA70 firmware version 2.28 2.18 2.28 2.18 2.18 Description 3 Update recommendation Connection environment Server connect Controller enclosure connect Update recommendation Recommended Varies, depending on array controller enclosure model and installed controller enclosure firmware.
HP StorageWorks 60/70 Modular Smart Array Enclosure Firmware v2.28 Release Notes (536920-006, May 2011) - Page 5

...perform this module from the HP website, right-click the... the storage system configuration is stable and is applicable to both server-attached ...intermittent issue where the enclosure returned incorrect Initiator Connection Tag (ICT) information to the initiator. ...-installed MSA70 firmware version is essential. Important notes IMPORTANT: • If currently-installed MSA70 firmware version...
HP StorageWorks 6X/7X Series Modular Storage Array Enclosure I/O Module Replacement Instructions (436502-001, November 2006) - Page 1

...servers. Squeeze the lever (1) and pull it down or restart. HP StorageWorks 6X/7X Series Modular Storage...device. Parts can be liable for the appropriate enclosure: MSA60 or MSA70. © Copyright 2006 Hewlett-Packard Development Company, L.P. c. Disconnect the power cords. 2. HP... connected to verify component failure: • Check the I /O module. 3. See the server ...
Redundancy in enterprise storage networks using dual domain SAS configurations - Page 2

...from the controller to storage devices. The higher failure rates are the result of the mechanical connection points and moving parts... requirement. In addition the Enterprise class SAS drives, HP has broadened the hard drive offerings with higher reliability and... creates an additional domain to provide dual-paths from servers to the drives. Customers seeking lower cost solutions can...
Redundancy in enterprise storage networks using dual domain SAS configurations - Page 8

... failure and make it possible to storage devices. Summary HP introduced dual port SAS hard drives during the last half of supporting two domains. The HP StorageWorks Dual Domain I/O Module Option Kit enables the 60 Modular Smart Array and 70 Modular Smart Array to support redundant pathways from servers to tolerate HBA failure, external cable...
HP StorageWorks 70 Modular Storage Array Setup Poster (434894-001, February 2007) - Page 3

...MSA70. Power cords The power cord should be walked on the HP website: http://www.hp.com. Connect the power cords to the plug, electrical outlet, and the point where the cord extends from the storage...and then the server. 5. To reduce the risk of supported cables, see the enclosure as an operational device. Powering up IMPORTANT: Always power up the servers. Loosen the ...
HP StorageWorks 70 Modular Storage Array Setup Poster (434894-001, February 2007) - Page 4

... and powering up the enclosure for Subscriber's Choice at: http://www.hp.com/go/myadvisory. • Press the up arrow key to the enclosure. To power up the servers. Sign up for the first time, be sure to verify that the MSA70 is connected to. • Press the up , the system power LED illuminates...
ISS Technology Focus, Number 14 - Page 1

... works by 100% or more. There are a good option for enterprise server storage. Three-bit MLC stores one cell. SLC-based SSDs provide the highest performance and endurance for read... applications of eight different charge states in each cell to ours: iTunes page. HP solid-state storage devices are now available on the NAND technology, write workloads, and the capacity of ...
ISS Technology Focus, Number 14 - Page 2

... storage devices, I /O into NAND reads and writes. IO accelerators I /O directly across the PCIe bus, resulting in lower latency performance advantages in a short time. This allows HP SSDs to monitor SSD usage and wear. This information can be ready in particular environments. Our portfolio consists of four classes of server CPUs to achieve higher block storage...
ISS Technology Focus, Number 14 - Page 3

...for our ProLiant DL360 G7, DL380 G6 and G7, and DL385 G6 and G7 servers. Table 1-1. AC power supplies HP offers 1200 W -48 V DC Common Slot Power Supplies with 90% efficiency specifically ... with that you choose the correct product. Table 1-1: Enterprise solid-state storage device classes Efficiency of the HP solid-state solutions. Follow these batteries using either AC power from the...
HP StorageWorks MSA60/70 I/O module Installation instructions for dual domain configurations (463073-002, April 2008) - Page 1

... such as directed on MSA and server components. Go to the Download drivers and software page for the MSA60 or MSA70. 3. Firmware will be installed after the I/O module is subject to an unpainted surface of the chassis. • Touch an unpainted surface of a USB storage device and the HP ProLiant Firmware Maintenance CD. © Copyright...
HP StorageWorks MSA60/70 I/O module Installation instructions for dual domain configurations (463073-002, April 2008) - Page 2

...complete, restart the storage system, and ...hp.com/go/msa. Page 2 Pull the I /O to complete. Schedule a maintenance window and stop all I /O module blank straight out of support for connecting...do not interrupt the update process. See the MSA60 or MSA70 QuickSpecs for the update to the MSA. Updating the &#...server using the files and instructions obtained in your dual domain...

Similar Questions

Wireless Connection
My printer cannot find an IP address when searching for a wireless connection. I am ten feet away fr...
(Posted by rex999999 12 years ago)
Ask a New Question
Use the box below to post a new question about this HP product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP MSA70 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls

Find comprehensive HP recall information updated hourly on RecallOwl.com.