Get support for HP ML330 - ProLiant - G3

HP ML330 Support Question

HP ML330 Support Question

Find answers below for this question about HP ML330 - ProLiant - G3.
Need a HP ML330 manual? We have 63 online manuals for this item!
Question posted by amar9823 on August 24th, 2012

Nmi:parity Check / Memory Parity Error *** System Has Halted Error***

NMI:Parity check / memory parity error*** system has halted error***  this error found with blue screen 

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related HP ML330 Manual Pages

HP Insight Server Migration Software for ProLiant User Guide - Page 6

... with the Emulex LPe1105-HP 4Gb FC HBA might cause a blue screen on the NIC adapter in SMP Agent Mode 131 Error during data copy of Linux migration 132 Destination server reboots continuously with... Table of Windows 2000 to a ProLiant server........134 Static IP address cannot be resized from a Windows 2008 application station 130 NTFS resize error message...130 SMP migration fails during ...
HP Insight Server Migration Software for ProLiant User Guide - Page 132

...a conflict with a blue screen If your most recent settings that all antivirus and firewall software is on the destination server manually. After Windows boots, install the ProLiant Support Pack on the... with the Emulex LPe1105-HP 4Gb FC HBA might cause a blue screen on the destination server A SAN migration of sectors error occurs in the source or destination log followed by a I/O ...
HP Insight Server Migration Software for ProLiant User Guide - Page 143

...memory and CPU resources, 15 overview, 13 uninstalling, 135 auto booting destination server fails troubleshooting, 128 B benefits, SMP, 13 blank screen appears when using SMP Boot CD to boot the server, 126 blue screen...by this version of SMP application, 127 disk space, requirements, 19 DNS error appears after migrating domain controllers, 134 documentation, accessing product, 24 domain controllers...
HP Insight Server Migration Software for ProLiant User Guide - Page 146

..., 128 blue screen, 132 corrective action is required before migrating preinstalled operating systems, 123 corrective action is required for source servers with HP iLO Management Channel Interface Drivers, 123 Deploy Agent task fails, 124, 128 destination server displays blank screen when using SMP Boot CD, 126 destination server identification fails, 126 DNS error appears...
Implementing Microsoft Windows Server 2008 on HP ProLiant servers - Page 23

... certain storage applications, including storage agents, SAS/SATA event services, and Array Configuration Utility (ACU). Issue 3 A blue screen error may be reported by certain storage applications for individual logical volumes, these polices are listed. Known issues on ProLiant servers (Windows Server 2008 32-bit and x64 editions) Issue Details Issue 1 The write cache and...
Memory technology evolution: an overview of system memory technologies, 7th edition - Page 11

... 8). HP introduced error correction code (ECC) memory in all HP ProLiant servers. The algorithm adds the check bits together to four bits within a single DRAM chip. However, the effectiveness of two random bits and up to calculate a checksum, which it corrects single-bit errors. It does not correct memory errors or detect multi-bit errors. ECC encodes information...
HP ProLiant Servers Troubleshooting Guide - Page 6

... failure 156 Automatic Operating System Shutdown Initiated Due to Overheat Condition 156 Blue Screen Trap: Cause [NT]...157 Corrected Memory Error Threshold Passed (Slot X, Memory Module Y 157 EISA Expansion Bus Master Timeout (Slot X 157 PCI Bus Error (Slot X, Bus Y, Device Z, Function X 157 Processor Correctable Error Threshold Passed (Slot X, Socket Y 157 Processor Uncorrectable Internal...
HP ProLiant Servers Troubleshooting Guide - Page 58

... may also point to fault detection tools that report errors and preserve the system configuration. Other useful resources include HP Insight Diagnostics (on page 74) and HP SIM ("HP Systems Insight Manager" on procedures, hardware options, software tools, and operating systems supported by a blue screen with white text, and the text may contain...
HP ProLiant Servers Troubleshooting Guide - Page 69

... a catastrophic operating system error occurs, such as the...includes an intelligent microprocessor, secure memory, and a dedicated network interface.... The ROMPaq utility checks the system and provides...blue screen, ABEND, or panic. ASR increases server availability by sending a message to a designated pager number that causes the system to exit RBSU. 10. Online versions of selected ProLiant...
HP ProLiant Servers Troubleshooting Guide - Page 90

... array accelerator board is installed, check for ADU version 7.85.16.0 and earlier. Action: If many parity errors occurred, you may need to ADU error messages This section contains a complete alphabetical list of the last 32 parity errors on transfers to the server documentation for multiple servers. Error messages 90 Displays starting memory address, transfer count, and operation...
HP ProLiant Servers Troubleshooting Guide - Page 97

... duplicate due to the detection of parity errors. Action: The drive or cable may need to be written to the array accelerator board in a drive bay other errors occur, upgrade the firmware to a version that supports monitor and performance, if desired. Duplicate Write Memory Error Description: Data cannot be replaced. Error Occurred Reading RIS Copy from...
HP ProLiant Servers Troubleshooting Guide - Page 108

... Be sure the controller is displayed, and the system halts. Unable to Retrieve Identify Controller Data. Then power the ...logical drive may have occurred. Unrecoverable Read Error Description: Read parity errors were detected when an attempt to read the... of the mirrored memory was unable to obtain it. Action: Check the other error messages for helpful error messages displayed by ...
HP ProLiant Servers Troubleshooting Guide - Page 110

...Memory Error Description: Data cannot be caused by the ACU diagnostics feature ("Diagnostics tasks" on the two controllers. This can be written to be sure that the board was replaced in EISA NVRAM. Action: Check the diagnosis screen... memory installed. Action: Replace the batteries if the batteries do not recharge within 36 powered-on hours. Make certain that a parity error...
HP ProLiant Servers Troubleshooting Guide - Page 120

... Slot x Audible Beeps: None Possible Cause: A PCI device has generated a parity error on the PCI bus. Error messages 120 Redundant ROM Detected - Power Fault Detected in PCI cards, remove the card. System DIMM Memory Audible Beeps: None Possible Cause: An uncorrectable error memory event occurred in a memory DIMM. Action: Reboot the server. Audible Beeps: None Possible Cause...
HP ProLiant Servers Troubleshooting Guide - Page 155

...Array Accelerator Read Error Occurred... ...Data in posted-writes memory. Audible Beeps: None Possible Cause: Array accelerator failed self-test. After pressing the F2 key, check integrity of 010**...follows: **001 of the file system and restore lost . Error messages 155 Audible Beeps: None Possible Cause: Hard parity error detected while reading data from backup. Action: Replace the array ...
HP ProLiant Servers Troubleshooting Guide - Page 157

... Memory) Corrected Memory Error Threshold Passed (Memory Module Unknown) Event Type: Correctable error threshold exceeded Action: Continue normal operation, and then replace the memory module during the next scheduled maintenance to the operating system documentation. PCI Bus Error (Slot X, Bus Y, Device Z, Function X) Event Type: Expansion bus error Action: Replace the PCI board. Blue Screen...
HP ProLiant Servers Troubleshooting Guide - Page 183

...97, 98, 110, 138, 141, 146, 148, 154, 155 array accelerator errors 154, 155 array accelerator memory size change detected 141 array accelerator module 146 array accelerator not responding 154 array ...110, 133 battery pack, array accelerator 141 beep codes 114 BIOS Serial Console 66 blank screen 52 blue screen event 157 boot options 66 booting problems 40 booting the server 40 C cables 17, ...
HP ProLiant Servers Troubleshooting Guide - Page 186

...memory 66, 67, 115 miscellaneous port 85 codes 166 modem problems 54 modems 54, 55 monitor 52 mouse 53 mouse problems 53 N network connection problems 62 network controller problems 56 network controllers 56, 57 network interconnect blades 57 new hardware 38 NMI... panic error 59 parallel port 131 parameters 62 parity errors 90...ProLiant Support Pack (PSP) 77 PSPs, overview 77 Q QuickSpecs 86 Index 186
HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide - Page 51

... restart when a catastrophic operating system error occurs, such as the Health Driver...ATA/100) • Support for RAID levels 0, 1, and 1+0 HP ProLiant ML330 Generation 3 Server Maintenance and Service Guide 3-1 However, when the operating system...ProLiant Essentials Foundation Pack. A system fail-safe timer, the ASR-2 timer, starts when the System Management driver, also known as a blue screen,...
HP ProLiant ML330 Generation 3 Server Setup and Installation Guide - Page 88

..., and memory modules. ...error occurs, such as the Health Driver, is loaded. However, when the operating system fails, the timer expires and restarts the server. A system fail-safe timer, the ASR-2 timer, starts when the System Management driver, also known as a blue screen...Management CD in the configuration. 5-16 HP ProLiant ML330 Generation 3 Server Setup and Installation Guide ...

Similar Questions

Critical Bios Error? Black Screen, No Boot And 6 Beeps With Red Led's?
Is there a fix for my critical bios error?Other than obtaining second Computer and downloading a bio...
(Posted by fatboybudd 5 years ago)
Nmi:parity Check/ Memory Parity Error Hp Proliant Dl 360 G5
i will install windows 2003 server for hp proliant dl360 g5 message NMI:parity check/ memory parity...
(Posted by adowlatkhahi 11 years ago)
Error Installing Windows Xp
what settings do i need to change in the bios to install windows xp pro so i don't get a blue screen...
(Posted by rael1969 12 years ago)
*** Hardware Malfunction Call Your Hardware Vendor For Support Nmi: Parity Che
*** Hardware Malfunction Call your hardware vendor for support NMI: Parity Check/Memory Parity Error...
(Posted by nanibandaru 12 years ago)
Ask a New Question
Use the box below to post a new question about this HP product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

HP Manuals

Find free HP ML330 - ProLiant - G3 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

HP Reviews

View thousands of HP user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete HP customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed HP customer service rankings, employee comments and much more from our sister site.

HP Recalls