Question posted by Retusa1sg on July 27th, 2016

Erro Code

what is check system pool VSC error: 56

Current Answers

Answer #1: Posted by TommyKervz on July 27th, 2016 11:48 PM
This answer was accepted by the poster of the original question.
TommyKervz

Member since:
January 10th, 2013

Points: 17,776,833
1,100
points


Hope that is helpful.
Kervz at www.satechhelp.co.za

Related Hayward EcoStar Manual Pages

EcoStar Manual - Page 17

Hayward EcoStar Pump SP3400VSP Thursday 1:27p 1725rpm 380 Watts Timer 1 timer will end at 11:45p
EcoStar Manual - Page 18

Configuration Menu Locked Configuration Menu press > to next item Time: Th 1:27PM + change or > skip Set Day and Time Thursday 1:27p Speed Selection rpm MAX allowed speed 3450 (600-3450rpm) MIN allowed speed 600 (600-3450rpm) Set max-speed Prime Period: Auto Sense Remote Control Mode Standalone/Hayward Set COMM Bus Address Pool Filter to adjust, > go to enter Use + / -
Technical Guide - Page 1

Variable Speed Pump and Drive Technical Guide © 2011 Hayward Pool Products Version 2 Drive FW 1.02 Interface FW 2.55 residential Interface FW 1.00 commercial
Technical Guide - Page 3

...codes for electrocution and could result in the owner's manual and on how to electric supply. To reduce the risk of electric shock, do NOT use an extension cord to connect unit to bond drive. Failure to pool....  Failure to bond drive to follow all applicable local codes, regulations, and the National Electric Code (NEC). Hazardous voltage can cause severe injury and/or death. ...
Technical Guide - Page 4

... flow does not exceed the capacity of pipe (L) between pump suction port and first elbow or fitting should be at least 5 times pipe size. Existing Pools: When installing the EcoStar on a new pool, care should be taken to ensure proper pipe and equipment sizing to handle the maximum flow required (fig 1). Plumbing New...
Technical Guide - Page 7

... Page 5 Note: When connecting high voltage for the low voltage data cable. One for high voltage and the other for an EcoStar that is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the control, or in ...Wire Terminal. Make sure the unit is below high voltage wires and should be determined by the NEC and local code requirements.
Technical Guide - Page 8

Installation-Interface removal/positioning The interface assembly on the EcoStar can be configured in four different positions. 1. Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Page 6 Remove the two screws as shown (fig 7, 9, 10 & 11) and re-secure with the two screws (fig 7). Reposition interface assembly as shown (fig 7). 2. Remove the interface assembly as shown (fig 8). 3.
Technical Guide - Page 9

... interface assembly (Page 7) remove the plug connecting the drive to the interface assembly. Figure 12 Figure 13 Figure 14 Page 7 Plug is included with the EcoStar and includes blank cover, mounting bracket and new terminal block for wall mount or control connection. 2. Wall mount kit is permanently attached (fig 13), install...
Technical Guide - Page 12

... to 2 on the controller, 8 on the pump to 3 on the controller and 1 on 7 EcoStar is data connected to a Hayward/Goldline control, voltage needs to come directly from a breaker in the control...Figure 23 Pump Terminal Data Plugs Page 10 Control Data Plug Software versions necessary to operate the EcoStar Aqua Logic/Pro Logic/Aqua Plus v2.65 or higher OnCommand 1.00 or higher E-Command 4...
Technical Guide - Page 24

.... Programming-Configuration Hayward/Goldline Compatible Software Control 13. Only the Menu, and Stop/Resume button is active on the EcoStar. The Goldline/Hayward controller will only recognize address 1 (Pool Filter) and address 2 (Aux 1/ Spa Filter). Note: In the Hayward/Goldline compatible software mode the timers do not need to a Hayward/Goldline compatible software...
Technical Guide - Page 25

... is 41º F. This speed can be adjusted between 600 rpm (17%) and 3450 rpm (100%) by pressing the & buttons. Setting will turn on the EcoStar, if stopped, to protect the drive . Enabling this feature will show in both "C" and "F". In this point you will be asked to set the Drive...
Technical Guide - Page 26

Programming-Configuration If you have an HCP3400VSP or HCP3400VSPVR commercial EcoStar please refer to continue. Press the button to page 39 for directions on the next screen. If yes, press and confirm on setting password protection. ...
Technical Guide - Page 32

...while the pump is a trip, both the Stop/Resume and Check System lights will be illuminated and the trip message below will ...starts it will begin to the speed selected or timed. If the EcoStar you will show on the interface. When the Low Temp Operation ... In Auto Prime, pump will see these screens Drive Error SVRS Trip alternate during configuration, prior to operate as long as one ...
Technical Guide - Page 35

Wiring Compartment Cover Interface Assembly Variable Speed Drive Figure 63 Motor/Fan Shroud Motor Page 33 Disassembly/Assembly This guide will only cover the disassembly of the EcoStar is exactly like the standard TriStar pump. The wet end disassembly of the drive and motor area for this guide.
Technical Guide - Page 41

... the user will see this point you will be prompted to 3 hrs by pressing the button. Press the button to continue. 3. If you have a commercial EcoStar you can set . Password Protection-Commercial 1.
Technical Guide - Page 44

... there are no continuity. There should be checked. Check continuity from the heatsink on the bottom of 230 VAC. Check fan and shroud for issues. If they are outside limits, replace motor. Check incoming line voltage (page 4) and verify that the motor is too high. Code/Fault Indications Drive Error! Follow disassembly/assembly procedures (pages 32...
Technical Guide - Page 46

... motor lead to lead. If they are connected correctly (page 10). Check to a Hayward/Goldline Controller, disconnect the com ground wire between interface and drive. If error still exists remove all (0) check connection between terminal 1 with EcoStar and terminal 4 with Hayward/Goldline Control (page 10). Ohms reading should be sure motor shaft turns freely...
Technical Guide - Page 48

... Troubleshooting/Fault Codes Code/Fault Indications Warning NO Comm Inspect the data wire between the control and EcoStar. If the values are correct, replace the drive. Control reads "Pool bridge comm".... Page 46 If the error has not been eliminated, check the Diagnostic Menu. Disconnect Blue, Black, and Red motor leads (page 4) from the pump drive. EcoStar is tripping. The breaker ...
Technical Guide - Page 49

Control reads "Pool bridge comm." wires between the pump interface and the control Check to make sure the Min and Max setting on in Standalone mode. EcoStar is configured for relay control (page 10) . No error on the EcoStar comm. Troubleshooting/Fault Codes Code/Fault Indications EcoStar is connected and configured to operate with the settings in the control...
Technical Guide - Page 50

... Engaged". This is wired and set to come on the pump interface do not work properly. The EcoStar is correct. This indicates that the comm. Troubleshooting/Fault Codes Code/Fault Indications The freeze protection in the EcoStar to the comm. If problem persists, purchase (2) model XPF 20A 3-wire noise filters through X-10 website. bus...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward EcoStar manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.