GE GG50T06PVK Support Question
Find answers below for this question about GE GG50T06PVK.Need a GE GG50T06PVK manual? We have 2 online manuals for this item!
Question posted by mjobrien911 on May 28th, 2011
Gg50t06pvk Ge Power Vent Water Heater
The ignitor on my unit turns on and gets hot but burner does not fire. Error code shows green light and the A and B light are on. Tech support sid dirty burner but it was blown clear with air still doesnt light. Now tech says a sensor above burner is bad???????????
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related GE GG50T06PVK Manual Pages
Use and Care Manual - Page 2
... . . . 21 Operating Instructions Lighting Instructions 22 Water Temperature . . . . . 23, 24
Care and Cleaning Draining 26 Maintenance 26 Vent System Inspection . . . . 27 Burner Inspection 27 Extended Shut-Down 28
... in death or serious injury and/or damage to use and maintain your water heater properly. CAUTION Notice:
An imminently hazardous situation that can save you and ...
Use and Care Manual - Page 3
... result in serious injury or death.
! INSTALL THE BLOWER ASSEMBLY AND PROPERLY VENT THE WATER HEATER... Failure to the Care and Cleaning section of the Installation Instructions in property damage... vicinity of a water heater or any questions, STOP, and get help from carbon monoxide, never operate this water heater unless it is properly vented and has an adequate air supply for proper...
Use and Care Manual - Page 4
... be considered when selecting the water temperature setting of being delivered, turn on the label pictured below details the approximate water temperature for each mark on the water heater. Be sure to be regulated by mixing hot and cold water in Scalds
! Contact a licensed plumber or the local plumbing authority for Hot Water SCALDS. Water temperatures above may require a 120...
Use and Care Manual - Page 7
...liquids which give off flammable vapors are to sufficiently support the weight of the water heater.
The auxiliary catch pan installation MUST conform to physical damage, for adequate inspection and servicing.
● The water heater may be installed under the water heater.
A minimum of natural air movement in all directions.
7
Troubleshooting Tips
Customer Service Care...
Use and Care Manual - Page 9
... capacity of the water heater flows back into the main supply line, and the result of controlling thermal expansion are 3/4" NPT on all models. In an "open drain. Replacing the relief valve will permanently damage the dip tube. The HOT and COLD water connections are clearly marked and are also available. Local codes or plumbing authority...
Use and Care Manual - Page 10
..., examine the piping and fittings for hot water distribution. Local codes shall govern the installation of the valve and must be installed between the relief valve and the tank.
Operating Instructions Installation Instructions Safety Instructions
Installing the water heater. The discharge line must pitch downward from the valve to vent from freezing. No valve of any...
Use and Care Manual - Page 12
.... It is important that the vent pipe engages fully into service.
Do not apply power until the adhesive has fully cured. or 3-inch diameter pipe. Support method used , and that the first hanger be corrected in accordance with water heater) on each connection. If the water heater is properly vented and has adequate air supply for proper operation as...
Use and Care Manual - Page 13
..., one (1) 90°elbow, and three (3) feet of horizontal pipe.
Care and Cleaning
Troubleshooting Tips
Customer Service
13 This water heater is approximately equal to 3 feet of pipe. If you decide to vent with Vent One (1) One (1) Two (2) Two (2)
Three (3)
Number of 45° Elbows
None One (1) None One (1)
None
Maximum Pipe Length in...
Use and Care Manual - Page 15
...from any forced air inlet to be a forced air inlet.
Outside of the vent terminal depends on the blower outlet. Minimum twelve (12) inches above roof level without additional support for Testing and Materials (ANSI/ASTM) standards. Connect vent elbow onto vertical pipe through the roof.
Mortar or Silicone Caulk Vent Pipe From Water Heater
Pipe Coupling
Horizontal...
Use and Care Manual - Page 16
...water heater vent connection.
type of pipe. NOTICE:...(provincial) or federal codes for proper fit, ...unit is one inch. In order to prevent condensate from pushing the pipe out of cement to the pipe end and insert
Appropriate solvent and
pipe into the water heater...power until it bottoms out. Care and Cleaning
Troubleshooting Tips
Customer Service
16
Use and Care Manual - Page 17
... accordance with local codes, or, in the absence of local codes, in the heater control enclosure.
The water heater must be installed on a GFCI circuit. NOTE: It is approximately 5.0 amps.
A knock-out hole is required.
If local codes do not permit the use of cord connections, a 120 V, 50/60 Hz power supply, with the power cord provided (DO...
Use and Care Manual - Page 19
... Manual and National Fuel Gas Code.
❑ DO contact a qualified service technician
if the pilot or main burner will not stay lit. The burner chamber is designed to the water heater.
❑ DO ensure that the venting system
complies with factory installed 3/4" NPT heat traps in the hot outlet line and cold water inlet line.
This should only...
Use and Care Manual - Page 20
...upward to chimney
(¼" per foot of length minimum) .
❑ Vent connector(s) securely fastened together
with water. ❑ Air purged from water heater and piping.
❑ Water connections tight and free of 1" from combustible surfaces
observed and water heater not installed on carpeted floor.
❑ Sufficient fresh air supply for possible gas leak.
❑ Gas Company inspected...
Use and Care Manual - Page 21
... valve in the installation of a heating system that any air in heating unit hot water supply line
and cold water return line (not supplied with water heater)
Heating unit
Care and Cleaning
Troubleshooting Tips
Customer Service
Combustion Air Inlet Openings
6" air gap
21
Local codes or plumbing authority requirements may be present and will be suitable for horizontal...
Use and Care Manual - Page 23
... the "OFF" position and turn off manual gas shut-off including their pilot burners, to the water heater. After the main burner ignites, replace the outer door. DANGER: Hotter water increases the Potential for safety) to read and follow the warnings outlined in a hot water system served by air currents from surrounding areas to avoid vapors lighting. Water Temperature Setting
The...
Use and Care Manual - Page 25
... of the rod. Make certain that all in a water pipe. Check the outdoor vent terminal to a drain. Inspect dilution air inlet. Clean any lint, dirt or oil accumulation that there is turned off valve before removing anode rod. A water heater's tank can
cause carbon monoxide
dangers, excessive hot water
temperatures and other
potentially hazardous
conditions.
25
Troubleshooting Tips...
Use and Care Manual - Page 26
... air inlet openings and any unusual burner operation is noted, the water heater should be replaced. To ensure sufficient ventilation and combustion air supply, proper clearances must be performed only by scrubbing with the main burner off until qualified service assistance can be placed against or next to be certain it involves the disconnection of the vent...
Use and Care Manual - Page 27
... Gas Caution in operation. Chlorination of time, the power and water to freezing temperatures. NOTICE: Do not remove the anode rod from the water heater's tank, except for an extended period of the water supply should be drained if they might be subjected to the appliance should be turned off to conserve energy and prevent a buildup...
Use and Care Manual - Page 29
... repair of the water heater. Refer repairs to recover after an abnormal demand.
Do not plug the relief valve outlet. Low gas pressure.
Water usage may be set too high.
The pilot burner may have exceeded the capacity of gas piping, gas control (thermostat), burners, vent connectors or other safety devices.
Verify power supply (120VAC).
Turn "ON". Safety...
Use and Care Manual - Page 30
...: Make certain power to water heater is too high, the valve will not operate. Wiring errors can cause improper...control, burners, vent connectors or other safety devices. Operating Instructions Installation Instructions Safety Instructions
Gas Valve LED Error Codes
Care... ignitor assembly could be damaged or broken. VERIFY PROPER OPERATION AFTER SERVICING. Inspect vent pipe and dilution air ...
Similar Questions
Ge Power Vent Water Heater
My water heater fires up and ignites but only runs for a few minutes then the flame goes out.It trie...
My water heater fires up and ignites but only runs for a few minutes then the flame goes out.It trie...
(Posted by miller19602003 9 years ago)
How To Get My Ge Gas Power Vent Water Heater Out Of Vacation Mode
(Posted by velocal 9 years ago)
Replace A Fv Sensor
I HAVE TO REPLACE A FV SENSOR THE GE COMPANY SEND ME A SENSOR BUT THEY SAID THEY CANT SEND SOME ON T...
I HAVE TO REPLACE A FV SENSOR THE GE COMPANY SEND ME A SENSOR BUT THEY SAID THEY CANT SEND SOME ON T...
(Posted by sherinaghaffari 12 years ago)