Dell R710 Support Question
Find answers below for this question about Dell R710 - PowerEdge - 4 GB RAM.Need a Dell R710 manual? We have 4 online manuals for this item!
Question posted by themab on December 29th, 2013
How To Clear System Log Error On R710
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell R710 Manual Pages
Hardware Manual - Page 16
... to configure the network mode.
Setup Menu
NOTE: When selecting an option in the SEL log.
Select the default information to view the Home screen. To navigate to the Home screen ...can continue. When the system is displayed during normal system operation when there are no error messages. Option DRAC Set error
Set home
Description
Select DHCP or Static IP to match an LCD message with a...
Hardware Manual - Page 23
...See "Setup Menu" to select the format in which the messages are displayed in the System Event Log (SEL).
Network data is automatically removed when that refer to boot, press the System ID button ... off the system and disconnect it from the display:
• Clear the SEL - LCD Status Messages
The LCD messages consist of errors or status messages. You can perform this task remotely, but you...
Hardware Manual - Page 24
... System Cooling Problems." Remove and reseat the PCIe expansion cards. Check battery. Cause
Corrective Actions
Check the system event log Remove AC power to the system for critical failure events.
E1216 3.3V Regulator failure. Ambient temperature has a See ...restart the system. Check battery. LCD Status Messages
Code Text
E1000 Failsafe voltage error. Contact support.
Hardware Manual - Page 28
...)
Code Text
Cause
Corrective Actions
E1620 Power Supply # (### W) AC power error.
E1624 Lost power supply redundancy. The power supply
See "Troubleshooting
subsystem is ... power to the system for 10 seconds and restart the system. Review & clear SEL. The system BIOS has reported an I /O channel check error. Specified power supply's AC input is no longer
Power Supplies." If the ...
Hardware Manual - Page 29
...
the problem persists, see
resides in PCI configuration space at bus Expansion Cards."
##, device ##, function
##. Card Risers." "Troubleshooting
Expansion Cards." PCI parity error on Slot #. Review & clear SEL. PCI system error on Slot #. If the
problem persists, the riser
card or system board is unable to the system for more information and then...
Hardware Manual - Page 30
..., and restart the system. If the problem persists, see "Getting Help." Remove AC power to the system for more information, and then clear the SEL. The system BIOS has determined there has been a fatal error in bus ##, device ##, function ##. E1716
Chipset IERR Bus ## Dev ## Function ##. The system BIOS has reported a chipset internal...
Hardware Manual - Page 31
...error on Bus ## Device ## Function ##
The system BIOS has reported a PCIe fatal error on a component that
Cards and Expansion-
See "Expansion
on Slot #. See "Getting Help." Review has experienced a fault.
& clear...configuration invalid configurations
mismatch. Reinstall the missing riser card(s).
Review & clear SEL.
See "Getting Help."
prevent the system from the
Check...
Hardware Manual - Page 36
... unable to check the SEL for more power than 24 24 hours of ten error messages can boot if throttled.
W1628
Performance degraded. Check PSU and system configuration. NOTE: For the full name of sustained charge. Review & clear log. W1228 RAID Controller battery capacity < 24hr.
The system configuration requires more information and then...
Technical Guide - Page 8
...standards-based commands designed to PowerEdge R610 and R810
Feature
Processor
Form Factor Front Side Bus # Sockets # Cores L2/L3 Cache Chipset DIMMs Min/Max RAM
R610 Intel® Xeon... 6, or 8
12MB, 18MB, or 24MB (shared) Intel® 7500
32 DDR3
1GB/512GB
PowerEdge R710 Technical Guide
8
Feature Comparison to integrate with the standard iDRAC Express or optional iDRAC Enterprise to help ...
Technical Guide - Page 13
...)
Optional add-in NICs:
Brocade® CNA (1020) Dual Port Server Adapter
Optional add in HBAs:
Brocade® 8 GB HBAs
Emulex® OCE10102-IX-DCNA iSCSI HBA stand-up adapter
Power Supply
Energy Smart: redundant hot-plug high-efficient 570W or... (optional)
Dell™ OpenManage™ Systems Management Microsoft® System Center Essential (SCE) 2010 v2
PowerEdge R710 Technical Guide
13
Technical Guide - Page 20
... LCD Panel Features section in the About Your System chapter in this mode, the power button can send error codes and messages to enter a secure mode through Setup, which secures the system hard drives.
PowerEdge R710 Technical Guide
20 Both iDRAC6 and BIOS can still be removed from the chassis. System status on...
Technical Guide - Page 21
... binding.
4.11.5 Power Off Security
The control panel is for the Real-Time Clock and CMOS RAM on the bezel secures the switch behind the bezel. The lock on the ICH9 chip.
4.14 ...
The port on Support.Dell.com. Some possible applications of custom logs or scratch pads for hard drive encryption features in the PowerEdge R710 Hardware Owner's Manual on the control panel is designed so the...
Technical Guide - Page 30
...DDR3 technology Up to 288 GB of RDIMM memory (eighteen 16 GB dual rank RDIMMs) Up to RDIMM thermal sensors Single Bit Error Correction SDDC (Single Device... to SPD EEPROM for access to 24 GB of three channels with A1 or B1. PowerEdge R710 Technical Guide
30 Dell
7 Memory
7.1 Overview
The PowerEdge R710 uses DDR3 memory, providing a high-performance...
Technical Guide - Page 33
...total memory capacity but does not support SDDC with identical memory modules. PowerEdge R710 Technical Guide
33 Correction of 1 GB memory modules per processor is possible in the Memory Optimized mode.
...setup.
7.8 Memory Scrubbing
The PowerEdge R710 memory interface supports memory demand and patrol scrubbing, single-bit correction and multi-bit error detection. Sparing requires identical ...
Technical Guide - Page 34
...An additional lane is designed to 5 Gb/s. Data is responsible for high-level protocol communications, including the
implementation of Generation 1 from 2.5 Gb/s to support the Intel Xeon 5500 and... is sent over the QPI links as a x4 link; Dell
8 Chipset
8.1 Overview
The PowerEdge R710 planar incorporates the Intel® Xeon® 5500 processor series chipset for I /O components. Each...
Technical Guide - Page 36
.../F2 error logging in CMOS Virtual KVM, CD, and floppy support UEFI 2.1 support Power management support, including DBS, Power Inventory, and multiple power profiles Intel TXT (5600 series) Intel AESNI (5600 series) The R710 BIOS does not support the following C-States: C0, C1, C1E, C3, and C6. The PowerEdge R710...
Technical Guide - Page 44
...form factor platforms.
PowerEdge R710 Technical Guide
44 The PERC 6/i uses the LSI 1078 ROC (RAID on Riser1. It incorporates two four-channel 6 Gb/s SAS IOCs for...; = 2 + 4
2.5‖ = 2 + 2
2.5‖ = 2 + 6
2.5‖ = 2 + 6
12.4 Storage Controllers
12.4.1 SAS 6/iR
The R710 internal SAS 6/iR HBA is an expansion card that plugs into a dedicated PCI Express x8 slot (four lanes wired).
Technical Guide - Page 45
...SDD)
PERC 6/E Adapter (PERC H800)
External SAS/SATA storage
PERC 5/E Adapter
Legacy external storage
PowerEdge
R710
Support
Slot
PCI PCI
IO
Con Bracket Con
RAID
Battery Backup
Yes-Max 1
Storage slot
x8
No...for internal storage options (SAS, SATA, or SSD HDD). It supports the internal 6 Gb/s backplane interface for optical and/or TBU
N/A
(no HDD)
Internal or
external SCSI
tape...
Technical Guide - Page 58
... console sharing Virtual flash Monitoring Sensor Monitoring and Alerting Real-time Power Monitoring Real-time Power Graphing Historical Power Counters Logging Features System Event Log RAC Log Trace Log
Base Management Functionality
iDRAC6 Express
iDRAC6 Enterprise
vFlash Media
...
Information Update - Page 1
... to 1333 MHz. - One and two memory modules per channel support up to 1067 MHz. - Three memory modules per channel support up to 24 GB. Dell PowerEdge R710-Information Update
System Memory
This document provides latest information on your system configuration such as the processor series, DIMM voltage (low or standard), and system...
Similar Questions
How To Clear The Error Log On A Dell R710
(Posted by zyxaerkk 10 years ago)
How To Clear Error Messages Poweredge R710
(Posted by DowdlCRiv 10 years ago)
How To Clear Eent Log Poweredge R710
(Posted by sbreeri 10 years ago)
Intermitent Bios Log Error.memory Size Different After Upgrade To 4 Gb.causes?
This problem is intermittent..sometimes it causes loading problems..other times no problems. Check o...
This problem is intermittent..sometimes it causes loading problems..other times no problems. Check o...
(Posted by apolosik 12 years ago)