Dell R710 Support Question
Find answers below for this question about Dell R710 - PowerEdge - 4 GB RAM.Need a Dell R710 manual? We have 4 online manuals for this item!
Question posted by heange on July 28th, 2014
How To Clear The Amber Light Error On A Dell R710
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell R710 Manual Pages
Hardware Manual - Page 14
...-swappable
Up to four 3.5-inch hot-swappable with flex bay
Up to AC power and an error has been detected, the LCD lights amber regardless of the buttons is pushed again.
Provides system ID, status information, and system error messages. One optional slim-line SATA DVD-ROM drive or DVD+RW drive.
The LCD...
Hardware Manual - Page 15
...off through the iDRAC utility, the LCD panel, or other tools.
The LCD backlight lights blue during POST, press and hold the system ID button for information on specific ... "LCD Status Messages" for more than five seconds to indicate an error condition. If the system hangs during normal operating conditions and lights amber to enter BIOS Progress mode. LCD Panel Features
1
23
4
Item...
Hardware Manual - Page 23
...." For other faults, you will turn amber. About Your System
23 For information on , the LCD message is automatically removed when that refer to view the error.
NOTE: If your system fails to ...sent or received. Turn off the system and disconnect it from the display:
• Clear the SEL - wait approximately ten seconds, reconnect the power cable, and restart the system.
Indicator Link ...
Hardware Manual - Page 155
... on the switch or hub.
If all cable connections. • If the activity indicator does not light, the network driver files might be damaged or missing. • Use another working cable, and turn...the NIC connector. If the problem is resolved, replace the serial device. See "Using Dell™ PowerEdge™ Diagnostics."
2 Restart the system and check for the NIC card. See "NIC Indicator Codes."...
Hardware Manual - Page 161
...startup without video output.
Troubleshooting Your System
161 See "Using Dell™ PowerEdge™ Diagnostics." See "General Memory Module Installation Guidelines."
9...system is operational, run the appropriate online diagnostic test.
Make any changes to step 14 if an error message appears indicating a fault with all applicable guidelines.
1 If the system is not operational, turn...
Hardware Manual - Page 173
..., print, or save test results
• Temporarily suspend testing if an error is detected or terminate testing when a user-defined error limit is a suite of menus and options for technical assistance. For information about using the PowerEdge Diagnostics, then use the online Dell PowerEdge Diagnostics.
System Diagnostics Features
The system diagnostics provides a series of diagnostic...
Hardware Manual - Page 202
... 82 removing, 81
drive carrier hard drive, 84
DVD drive See optical drive.
E
error messages, 56 expansion cards
See PCIe expansion cards. expansion-card riser 1
connectors, 185 installing...removing, 99 cover closing, 79 opening, 79
D
damaged systems troubleshooting, 157
Dell contacting, 189
diagnostics testing options, 174 using Dell PowerEdge Diagnostics, 173
DIMMs See memory modules (DIMMs).
Technical Guide - Page 8
... helps eliminate the need to PowerEdge R610 and R810
Feature
Processor
Form Factor Front Side Bus # Sockets # Cores L2/L3 Cache Chipset DIMMs Min/Max RAM
R610 Intel® Xeon®...performing a comprehensive set of your needs and designs solutions for effective control. Dell
1.1.5 Easy to Manage
The PowerEdge R710 lets you devote more focus to help reduce IT complexity, lower costs, and...
Technical Guide - Page 16
... and Indicators section in the About Your System chapter of the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com for more information.
4.5 Power Supply Indicators
The PowerEdge R710 redundant power supplies have one status bi-color LED: green for AC power present and amber for a fault as detailed in the About Your System chapter of...
Technical Guide - Page 20
...PowerEdge R710 Hardware Owner's Manual on Support.Dell.com.
4.11 Security
For additional information regarding the following security features, see the PowerEdge R710 Hardware Owner's Manual on Support.Dell.com.
4.11.1 Cover Latch
The PowerEdge R710... error codes and messages to the chassis.
4.11.2 Bezel
A metal bezel is operating correctly or when the system needs attention. PowerEdge R710 ...
Technical Guide - Page 21
...
See the Jumpers and Connectors chapter in the PowerEdge R710 Hardware Owner's Manual on the planar to provide backup power for binding.
4.11.5 Power Off Security
The control panel is located inside the chassis. In addition, there is used to contain FRU information including Dell part number, part revision level, and serial number...
Technical Guide - Page 24
...Dell
Storage Maximum Vibration Operating Storage Maximum Shock Operating Storage
Altitude Operating
Storage
5% to 35,000ft)
5.6 Power Consumption Testing
Table 6. Power Consumption Testing
Feature Dimensions
Energy Smart Power Supply High-Output Power Supply L-206.4 mm1 x W-67.5 mm x H-76.5 mm
Status Indicators
1 x bi-color Light... handle or ejection tab
PowerEdge R710 Technical Guide
24
Technical Guide - Page 30
... power when DIMMs are 1 GB or 2 GB UDIMMs.
7.2.1 Memory Modes
The memory mode is dependent on RDIMMs and UDIMMs Multi Bit Error Detection Support for Memory Optimized Mode Support for Advanced ECC mode Support for Memory Mirroring Support for quad rank. Dell
7 Memory
7.1 Overview
The PowerEdge R710 uses DDR3 memory, providing a high...
Technical Guide - Page 33
... setup.
7.8 Memory Scrubbing
The PowerEdge R710 memory interface supports memory demand and patrol scrubbing, single-bit correction and multi-bit error detection. Dell
7.7 Sparing
Systems with SDDC in...Additionally, correction of 1 GB memory modules per processor is possible in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.dell.com. PowerEdge R710 Technical Guide
33
Technical Guide - Page 36
...split segments The other via the I2C bus. PowerEdge R710 Technical Guide
36 Dell
9 BIOS
9.1 Overview
The R710 BIOS is based on the Dell BIOS core, supporting the following features:
Intel...bus for efficient inter-integrated circuit control. The R710 supports all of POST USB 2.0 (USB boot code is 1.1 compliant) F1/F2 error logging in CMOS Virtual KVM, ...
Technical Guide - Page 39
... and 15 W for the third and
fourth cards (lower power support on Support.dell.com.
PowerEdge R710 Technical Guide
39 The system does not support hot-plug or hot-removal of two... Expansion-Card Risers section in the Installing System Components chapter in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com.
11.4 Quantities and Priorities
Refer to the Expansion Cards and...
Technical Guide - Page 40
Dell
11.5 PCI Card Dimensions
For information about PCIe slots and card dimensions, see the Expansion Cards and Expansion-Card Risers section in the Installing System Components chapter in the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com. PowerEdge R710 Technical Guide
40
Technical Guide - Page 42
...the Dell PowerEdge R710 Systems Hardware Owner's Manual on Support.Dell.com.
12.3 RAID Configurations
See Table 11 for status information. The bicolor LED is still installed in the system. Dell
12... visible from the front of a storage controller. The activity LED is a bicolor (green/amber) LED for information on the backplane. A 3.5‖ hard-drive backplane is controlled by the...
Technical Guide - Page 53
Dell
15 Operating Systems
For detailed information, see the following: Operating System Support Matrix for Dell PowerEdge Systems on www.Dell.com Dell PowerEdge R710 Systems Getting Started With Your System guide on Support.Dell.com
PowerEdge R710 Technical Guide
53
Technical Guide - Page 55
...lights-out environments.
To access the Unified Server Configurator, press the key within 10 seconds of interdependent pieces:
Dell Lifecycle Controller Unified Server Configurator iDRAC6
Dell...Dell.com
Integration with Dell support automatically directed to latest versions of Embedded Server Management. Dell
16.3 Embedded Server Management
The PowerEdge R710 ...
Similar Questions
How To Clear Sel On Dell R710 If System Is Not Booting
(Posted by Hahpte 10 years ago)
How To Clear System Log Error On R710
(Posted by themab 10 years ago)
Problems With The System Board
Blinking Amber Light
will this be an ongoing problem
will this be an ongoing problem
(Posted by pbronson 12 years ago)