Dell PowerEdge R710 Support Question
Find answers below for this question about Dell PowerEdge R710.Need a Dell PowerEdge R710 manual? We have 15 online manuals for this item!
Question posted by MonstJMelin on March 2nd, 2014
R710 Clear Sel How To
The person who posted this question about this Dell product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.
Current Answers
There are currently no answers that have been posted for this question.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Be the first to post an answer! Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.
Related Dell PowerEdge R710 Manual Pages
Glossary - Page 6
![](/manualimages/2/a/dell-poweredge-c2100-glossary-e1a3c40_6_dc9f.png)
![](/manualimages/2/a/dell-poweredge-c2100-glossary-e1a3c40_6_dc9f.png)
... RAC - Memory that is expressed as a diskette drive or keyboard, connected to servers and storage systems in rows and columns to run on your system. OID - ...local-bus implementation. parity - You can contain multiple logical drives. PCI - Power distribution unit. PowerEdge RAID controller. provider - PXE - Nanosecond(s). You must usually be revised to create an image....
Dell
PowerEdge Deployment Guide - Page 2
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_2_d779.png)
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_2_d779.png)
...and Xeon are trademarks of Dell Inc. Dell, the DELL logo, and the DELL badge, Dell OpenManage, and PowerEdge are either trademarks or registered trademarks of Dell Inc. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED ... States and/or other countries. Microsoft, Windows, and Windows Server are trademarks of Intel Corporation in the United States and/or other countries.
Dell
PowerEdge Deployment Guide - Page 3
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_3_a9bb.png)
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_3_a9bb.png)
PowerEdge Deployment Guide
Table of Contents
Introduction ...2 Unified Server Configurator (USC) Deployment ...2 Dell Systems Build and Update Utility (SBUU) ...3 Dell OpenManage™ Deployment Toolkit (DTK)...3 Manual Installation of Microsoft Operating Systems 4 Microsoft WDS (Legacy Images) / RIS ...4 WinPE ...4 Microsoft Automated Deployment Service (ADS) ...4
Page 1
Dell
PowerEdge Deployment Guide - Page 4
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_4_2035.png)
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_4_2035.png)
... iDRAC features.
Failing to work with Broadcom NetXtreme Devices on Dell Servers with the 11th Generation PowerEdge servers. The controller includes 1 GB of the Dell logo being displayed ...letter C: to support iSCSI and TOE. Drive Lettering Warning: Since the 11th Generation PowerEdge servers contain an embedded storage device, Microsoft Windows 2003 may see Best Practices for the ...
Dell
PowerEdge Deployment Guide - Page 5
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_5_6bd2.png)
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_5_6bd2.png)
.... Dell OpenManage™ Deployment Toolkit (DTK)
The Dell OpenManage Deployment Toolkit (DTK) is on the server. 2) At POST, press < F11> when prompted for BIOS Boot Manager. 3) Highlight the optical drive... Installation Summary page and click Apply Now. however, Dell plans to add this tool. PowerEdge Deployment Guide
Dell Systems Build and Update Utility (SBUU)
The SBUU is a collection of...
Dell
PowerEdge Deployment Guide - Page 6
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_6_6690.png)
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_6_6690.png)
...using the drivers setup.exe and a cmdlines.txt file. For the 11th Generation PowerEdge servers, you are installed.
Additional information is added per the Microsoft WDS / RIS documentation...Microsoft Knowledge Base article 254078 on http://support.microsoft.com/kb/315279. PowerEdge Deployment Guide
Manual Installation of Microsoft Operating Systems
This installation method involves booting...
Dell
PowerEdge Deployment Guide - Page 7
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_7_6e19.png)
![](/manualimages/q/l/dell-poweredge-r410-dell-poweredge-deployment-guide-c52adec_7_6e19.png)
PowerEdge Deployment Guide This error continues even after ensuring that all needed drivers are added to use WinPE instead of the default deployment agent.
Page 5 The ...://support.microsoft.com/?id=970721
Using UEFI
For additional information about using UEFI, see Deploying UEFI-Aware Operating Systems on Eleventh Generation Dell TM PowerEdgeTM Servers.
Information Update - System Setup Program - Page 1
![](/manualimages/j/8/dell-poweredge-r710-information-update-setup-program-b1a8527_1_1437.png)
![](/manualimages/j/8/dell-poweredge-r710-information-update-setup-program-b1a8527_1_1437.png)
NOTE: Applies to PowerEdge R410, R510, R610, R710, R910, T410, T610, and T710 systems only. December 2010 Integrated Devices Screen Option
Option
SR-IOV-Global Enable (Disabled default)
Description
Enables/disables BIOS configuration ...
Information Update - System Setup Program - Page 9
![](/manualimages/j/8/dell-poweredge-r710-information-update-setup-program-b1a8527_9_6b3d.png)
![](/manualimages/j/8/dell-poweredge-r710-information-update-setup-program-b1a8527_9_6b3d.png)
Integrated Devices 1
表 1 Integrated Devices
SR-IOV-Global Enable (SR-IOV
Disabled
説明
SR-IOV(Single Root I/O Virtualization BIOS PowerEdge R410、R510、R610、 R710、R910、T410、T610、T710
2010 年 12 月
Information Update - System Setup Program - Page 11
![](/manualimages/j/8/dell-poweredge-r710-information-update-setup-program-b1a8527_11_02c1.png)
![](/manualimages/j/8/dell-poweredge-r710-information-update-setup-program-b1a8527_11_02c1.png)
Integrated Devices
옵션
SR-IOV-Global Enable (SR-IOV-Global Disabled
설명
SR-IOV (Single Root I/O Virtualization) 장치의 BIOS PowerEdge R410, R510, R610, R710, R910, T410, T610 및 T710
2010 년 12 월 표 1에는 Integrated Devices
표 1.
Information Update - System Memory - Page 1
![](/manualimages/j/5/dell-poweredge-r710-information-update-memory-47493ed_1_8413.png)
![](/manualimages/j/5/dell-poweredge-r710-information-update-memory-47493ed_1_8413.png)
...-rank memory modules: - NOTE: Actual memory speed depends on the supported memory configurations listed in the Hardware Owner's Manual at support.dell.com/manuals. Dell PowerEdge R710-Information Update
System Memory
This document provides latest information on your system configuration such as the processor series, DIMM voltage (low or standard), and system...
Information Update - Intel Xeon 5600 Series
Processors - Page 1
![](/manualimages/v/0/dell-poweredge-r710-information-update-intel-xeon-5600-series-processors-80da6ce_1_7942.png)
![](/manualimages/v/0/dell-poweredge-r710-information-update-intel-xeon-5600-series-processors-80da6ce_1_7942.png)
... do not support 130 W Intel Xeon 5600 series processors. NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to support Intel Xeon 5600 ... 5600 series processor.
• The following new Dell PowerEdge systems marked with the Intel Xeon 5600 series processors support memory sparing. R710 - T610 - NOTE: The modular systems, PowerEdge M610 and M710, support the 130 W Intel Xeon ...
Information Update - Intel Xeon 5600 Series
Processors - Page 2
![](/manualimages/v/0/dell-poweredge-r710-information-update-intel-xeon-5600-series-processors-80da6ce_2_f909.png)
![](/manualimages/v/0/dell-poweredge-r710-information-update-intel-xeon-5600-series-processors-80da6ce_2_f909.png)
... memory modules per channel is backward-compatible to Intel Xeon 5500 series and operates at 1.35 V. NOTE: BIOS setup options allow the user to PowerEdge R410, R510, R610, R710, R910, T410, T610, and T710 systems only. Operating the system memory at support.dell.com/manuals. Systems with 1.35 V DDR3L memory operates the...
Information Update - Page 1
![](/manualimages/m/k/dell-poweredge-r710-information-update-b723a7a_1_345a.png)
![](/manualimages/m/k/dell-poweredge-r710-information-update-b723a7a_1_345a.png)
...and Support website at support.microsoft.com: • Systems running Microsoft® Windows Server® 2003 or Windows Server 2008
cannot be affixed once they have been removed.
MAC Address Label
For security ...support.microsoft.com/kb/968410. NOTE: On Dell PowerEdge R610 and PowerEdge R710 systems, the labels are prompted to support the iDRAC6 Enterprise virtual flash feature.
Information Update - Page 3
![](/manualimages/m/k/dell-poweredge-r710-information-update-b723a7a_3_e8ba.png)
![](/manualimages/m/k/dell-poweredge-r710-information-update-b723a7a_3_e8ba.png)
... iSCSI USB iSCSI Microsoft support.microsoft.com/kb/968410。
Dell 提供的 VFlash iDRAC6 Enterprise iDRAC GUI
Unified Server Configurator
Red Hat® Enterprise Linux® 5.3 Unified Server Configurator
MAC
NIC 和 iDRAC6 Enterprise MAC
注:在 Dell PowerEdge R610 和 PowerEdge R710 PowerEdge T610
2009 年 3 月
Information Update - Page 10
![](/manualimages/m/k/dell-poweredge-r710-information-update-b723a7a_10_e1a2.png)
![](/manualimages/m/k/dell-poweredge-r710-information-update-b723a7a_10_e1a2.png)
... R610/R710 PowerEdge T610
Dell™ Update Package
Dell Update Package(DUP
DUP
Windows Windows Windows VFlash
注意 : DUP を VFlash
2009 Dell Inc Dell Inc Dell および DELL ロゴは Dell Inc Microsoft、 Windows および Windows Server Microsoft Corporation Red Hat およ...
Hardware Owner's Manual - Page 28
![](/manualimages/e/b/dell-poweredge-r710-hardware-owners-manual-e6a867b_28_300d.png)
![](/manualimages/e/b/dell-poweredge-r710-hardware-owners-manual-e6a867b_28_300d.png)
...error. Check PSU cables. E1624 Lost power supply redundancy. PSU2 = ### W. Review & clear SEL. Remove AC power to the system, reduce the hardware configuration or install higher-wattage power ..., and then restart the system. The system configuration requires more information and then clear the SEL.
LCD Status Messages (continued)
Code Text
Cause
Corrective Actions
E1620 Power Supply #...
Hardware Owner's Manual - Page 29
![](/manualimages/e/b/dell-poweredge-r710-hardware-owners-manual-e6a867b_29_f6cd.png)
![](/manualimages/e/b/dell-poweredge-r710-hardware-owners-manual-e6a867b_29_f6cd.png)
..."Troubleshooting
Expansion Cards." PCI system error on a component that
the problem persists, see
resides in PCI
"Troubleshooting
configuration space at bus ##, device ##, function ##. Review & clear SEL. LCD Status Messages (continued)
Code Text
Cause
Corrective Actions
E1711 PCI parity error on Bus ## Device ## Function ##
The system BIOS has reported a PCI parity error...
Hardware Owner's Manual - Page 30
![](/manualimages/e/b/dell-poweredge-r710-hardware-owners-manual-e6a867b_30_6726.png)
![](/manualimages/e/b/dell-poweredge-r710-hardware-owners-manual-e6a867b_30_6726.png)
... system BIOS has reported a chipset internal error that the specified processor has had an internal error. Check the SEL for more information, and then clear the SEL. E1717
CPU # internal error.
Review & clear SEL. Remove AC power to the system for 10 seconds, and restart the system.
The system BIOS has determined there has been...