... Current Firmware Version 9 2.2. z Copying and reproduction of this update guide are proprietary to the use of this guide. z The illustrations and LCD screens as shown in this update guide in whole or in this update guide are for instructional purposes only, and may appear somewhat different from those on the firmware, some functions or specifications resulting from the version upgrades, please check the following Yamaha website. Uploading...
... Current Firmware Version 9 2.2. z Copying and reproduction of this update guide are proprietary to the use of this guide. z The illustrations and LCD screens as shown in this update guide in whole or in this update guide are for instructional purposes only, and may appear somewhat different from those on the firmware, some functions or specifications resulting from the version upgrades, please check the following Yamaha website. Uploading...
CobraNetCM-1 Upgrade Guide
Page 2
... cable or z Two Ethernet category 5 straight cables and a switching hub CobraNet Devices to be updated ACU16-C, NHB32-C, MY16-C, MY16-CII, DME8i-C, DME8o-C or DME4io-C CobraNet Discovery This is required for connection. Do not update firmware provided by a third party other than Yamaha may cause your device from the following hardware and software are required. Preparation 1.1. In this update guide, it is used...
... cable or z Two Ethernet category 5 straight cables and a switching hub CobraNet Devices to be updated ACU16-C, NHB32-C, MY16-C, MY16-CII, DME8i-C, DME8o-C or DME4io-C CobraNet Discovery This is required for connection. Do not update firmware provided by a third party other than Yamaha may cause your device from the following hardware and software are required. Preparation 1.1. In this update guide, it is used...
CobraNetCM-1 Upgrade Guide
Page 3
...-C MY16-CII DME8i-C/DME8o-C/DME4io-C ACU16-C/NHB32-C Ethernet category 5 cross cable PC When you use straight cables, connect a PC LAN connector via the switching hub to the CobraNet device connector (PRIMARY or SECONDARY connector) as shown below: Ethernet category 5 Ethernet category 5 MY16-C MY16-CII straight cable Switching straight cable Hub DME8i-C/DME8o-C/DME4io-C PC ACU16-C/NHB32-C CobraNet Interface Update Guide 3 1.2.
...-C MY16-CII DME8i-C/DME8o-C/DME4io-C ACU16-C/NHB32-C Ethernet category 5 cross cable PC When you use straight cables, connect a PC LAN connector via the switching hub to the CobraNet device connector (PRIMARY or SECONDARY connector) as shown below: Ethernet category 5 Ethernet category 5 MY16-C MY16-CII straight cable Switching straight cable Hub DME8i-C/DME8o-C/DME4io-C PC ACU16-C/NHB32-C CobraNet Interface Update Guide 3 1.2.
CobraNetCM-1 Upgrade Guide
Page 4
... the default setting. CobraNet Interface Update Guide 4 1.3. Installation and Default Setting of CobraNet Discovery from the "Start" menu to the following Cirrus Logic, Inc website and install. C:╲Program Files╲Cirrus Logic╲CobraNet Discovery╲firmware Above folder name differs if you wish to update to launch CobraNet Discovery. Firmware file names depend on the devices. Copy the firmware you change the...
... the default setting. CobraNet Interface Update Guide 4 1.3. Installation and Default Setting of CobraNet Discovery from the "Start" menu to the following Cirrus Logic, Inc website and install. C:╲Program Files╲Cirrus Logic╲CobraNet Discovery╲firmware Above folder name differs if you wish to update to launch CobraNet Discovery. Firmware file names depend on the devices. Copy the firmware you change the...
CobraNetCM-1 Upgrade Guide
Page 5
.... 7. Select the network adapter used to connect the device you wish to update from the "View" menu. You should be assigned manually if it cannot be updated properly by automatic setting. (See page 7) 6. CobraNet Interface Update Guide 5 Turn on the device while connecting to the device you wish to update. Click [OK] to assign the IP Address automatically, and then check [Enable Auto Assignment]. However, the...
.... 7. Select the network adapter used to connect the device you wish to update from the "View" menu. You should be assigned manually if it cannot be updated properly by automatic setting. (See page 7) 6. CobraNet Interface Update Guide 5 Turn on the device while connecting to the device you wish to update. Click [OK] to assign the IP Address automatically, and then check [Enable Auto Assignment]. However, the...
CobraNetCM-1 Upgrade Guide
Page 6
... been completed. Follow the "1.4. IP Address Manual Setting" on page 7 and assign the IP Address manually. CobraNet Interface Update Guide 6 8. If the IP Address is not assigned properly. Updating procedure" (page 9). Check again the cable connection and the network adapter. If "Request timeout" appears in the "errorCount" column and the "sysDescription" column. A number and firmware name/version number will appear in the "IP Address...
... been completed. Follow the "1.4. IP Address Manual Setting" on page 7 and assign the IP Address manually. CobraNet Interface Update Guide 6 8. If the IP Address is not assigned properly. Updating procedure" (page 9). Check again the cable connection and the network adapter. If "Request timeout" appears in the "errorCount" column and the "sysDescription" column. A number and firmware name/version number will appear in the "IP Address...
CobraNetCM-1 Upgrade Guide
Page 7
... menu. CobraNet Interface Update Guide 7 Type "ipconfig /all" in the CobraNet Discovery window, and select "New IP Address" from the "Start" menu to set the IP Address manually. 1. IP Address Manual Setting (if not updated properly by Automatic Setting) The manual setting is shown below to open the window for PC's IP Address check. 2. The PC's IP address is a number shown at the "IP...
... menu. CobraNet Interface Update Guide 7 Type "ipconfig /all" in the CobraNet Discovery window, and select "New IP Address" from the "Start" menu to set the IP Address manually. 1. IP Address Manual Setting (if not updated properly by Automatic Setting) The manual setting is shown below to open the window for PC's IP Address check. 2. The PC's IP address is a number shown at the "IP...
CobraNetCM-1 Upgrade Guide
Page 8
... box. CobraNet Interface Update Guide 8 If the last number of the PC's IP Address for the last number. Enter the same numbers of the PC's IP Address is different from the PC's IP Address, for the first three numbers. The first three numbers are the same numbers as shown below. The dialog box for setting the IP Address will...
... box. CobraNet Interface Update Guide 8 If the last number of the PC's IP Address for the last number. Enter the same numbers of the PC's IP Address is different from the PC's IP Address, for the first three numbers. The first three numbers are the same numbers as shown below. The dialog box for setting the IP Address will...
CobraNetCM-1 Upgrade Guide
Page 9
... update before turning on the device you wish to update in the CobraNet Discovery main window. It should be shown such as "Yamaha CNT Module CobraNet version 2.11.4 CS181022" in the "sysDescription" column in the CobraNet Discovery window, and select "Update Firmware" from the pop-up menu. If the latest version provided by Yamaha is the current firmware version number. CobraNet Interface Update Guide...
... update before turning on the device you wish to update in the CobraNet Discovery main window. It should be shown such as "Yamaha CNT Module CobraNet version 2.11.4 CS181022" in the "sysDescription" column in the CobraNet Discovery window, and select "Update Firmware" from the pop-up menu. If the latest version provided by Yamaha is the current firmware version number. CobraNet Interface Update Guide...
CobraNetCM-1 Upgrade Guide
Page 10
... Firmware Version" dialog box will be shown while updating. the example below is shown for a while as shown below. 3. Never turn the power off during updating, since this progress bar is selected (x.x.x represents the version number; CobraNet Interface Update Guide 10 When you wish to malfunction. Click [Update] to update MY16-CII, check that "YAMAHA-MY16CII version x.x.x" is shown on the display...
... Firmware Version" dialog box will be shown while updating. the example below is shown for a while as shown below. 3. Never turn the power off during updating, since this progress bar is selected (x.x.x represents the version number; CobraNet Interface Update Guide 10 When you wish to malfunction. Click [Update] to update MY16-CII, check that "YAMAHA-MY16CII version x.x.x" is shown on the display...
CobraNetCM-1 Upgrade Guide
Page 11
5. U.R.G., Pro Audio & Digital Musical Instrument Division, Yamaha Corporation © 2006 Yamaha Corporation A0 CobraNet Interface Update Guide 11 Updating is now complete. Click [OK] to close the pop-up window below and turn off the device. 6. Turn on the device again.