... be installed in longer drying times. The dryer must be considered. ■ A level floor with elbow. The combined weight of the dryer. See "Venting Requirements." ■ A separate 15 or 20-amp circuit needed for gas dryers and 30-amp circuit needed for electric dryers. ■ If you will need 18...is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Steam (Electric or Gas) A 38" (965 mm) B 32 9/16" (827 mm) C 27" (686 mm) D 52 9/16" (1335 mm) Non-Steam (Electric or Gas) 38" (965 mm) 31 1/2" (800 mm) 27" (686 mm) 51 1/2" (1308 mm) NOTE...
... be installed in longer drying times. The dryer must be considered. ■ A level floor with elbow. The combined weight of the dryer. See "Venting Requirements." ■ A separate 15 or 20-amp circuit needed for gas dryers and 30-amp circuit needed for electric dryers. ■ If you will need 18...is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Steam (Electric or Gas) A 38" (965 mm) B 32 9/16" (827 mm) C 27" (686 mm) D 52 9/16" (1335 mm) Non-Steam (Electric or Gas) 38" (965 mm) 31 1/2" (800 mm) 27" (686 mm) 51 1/2" (1308 mm) NOTE...
Installation Instructions
Page 6
... mm) 5" (127 mm) *Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed. Dryer only A B C* D E* Steam (Electric or Gas) Non-Steam (Electric or Gas) A 0" (0 mm) 0" (0 mm) B 38" (965 mm) 38" (965 mm) C* 1" (25 mm) 1" (25 mm) D 27" (686 mm) 27" (686 mm) E* 1" (25 mm) 1" (25 mm) *Required spacing NOTE: Some models are required. Installation...
... mm) 5" (127 mm) *Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed. Dryer only A B C* D E* Steam (Electric or Gas) Non-Steam (Electric or Gas) A 0" (0 mm) 0" (0 mm) B 38" (965 mm) 38" (965 mm) C* 1" (25 mm) 1" (25 mm) D 27" (686 mm) 27" (686 mm) E* 1" (25 mm) 1" (25 mm) *Required spacing NOTE: Some models are required. Installation...
Installation Instructions
Page 7
... 280) or Standard CAN/CSA-Z240 MH. Additional installation requirements This dryer is allowed. 24 in.2 * (155 cm2) 3"* (76 mm) 6"* (152 mm) 1"* (25 mm) 76" (1930 mm) A* 1" 27" 1" (25 mm) (686 mm) (25 mm) Steam (Electric or Gas) Non-Steam (Electric or Gas) A* 5 ½" (140 mm) 5" (127 mm) *Required spacing NOTE: Some models are...
... 280) or Standard CAN/CSA-Z240 MH. Additional installation requirements This dryer is allowed. 24 in.2 * (155 cm2) 3"* (76 mm) 6"* (152 mm) 1"* (25 mm) 76" (1930 mm) A* 1" 27" 1" (25 mm) (686 mm) (25 mm) Steam (Electric or Gas) Non-Steam (Electric or Gas) A* 5 ½" (140 mm) 5" (127 mm) *Required spacing NOTE: Some models are...
Installation Instructions
Page 13
...38 ft (11.6 m) 3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m) 4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m) Install Vent System 1. Find the diamond marking. 4. Leave enough room to move and install dryer. Using a 4" (102 mm) clamp, connect vent to exhaust outlet in longer drying times and increased energy... inlet hose and replace with 4" (102 mm) clamp. 3. Install exhaust hood. Use clamps to dryer location. Do not use vent runs longer than those specified in the flexible gas line. 4. If "Y" connector cannot be attached directly to the cold water faucet, the short hose ...
...38 ft (11.6 m) 3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m) 4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m) Install Vent System 1. Find the diamond marking. 4. Leave enough room to move and install dryer. Using a 4" (102 mm) clamp, connect vent to exhaust outlet in longer drying times and increased energy... inlet hose and replace with 4" (102 mm) clamp. 3. Install exhaust hood. Use clamps to dryer location. Do not use vent runs longer than those specified in the flexible gas line. 4. If "Y" connector cannot be attached directly to the cold water faucet, the short hose ...
Dimension Guide
Page 1
...27" 1" (25 mm) (686 mm) (25 mm) For dryer on pedestal; Use the fewest 90° turns possible. See Installation Instructions, "Venting Requirements." gas. Duet Steam and Non-Steam Electronic Gas Dryer PRODUCT MODEL NUMBERS WGD9450W, WGD9470W, WGD9550W, WGD9600T, WGD9750W, WGD9610X Gas supply: This dryer ... 1/2" IPS. For complete details, see Installation Instructions packed with the National Fuel Gas Code ANSI Z223.1. Do not overtighten. Dryer can result. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right...
...27" 1" (25 mm) (686 mm) (25 mm) For dryer on pedestal; Use the fewest 90° turns possible. See Installation Instructions, "Venting Requirements." gas. Duet Steam and Non-Steam Electronic Gas Dryer PRODUCT MODEL NUMBERS WGD9450W, WGD9470W, WGD9550W, WGD9600T, WGD9750W, WGD9610X Gas supply: This dryer ... 1/2" IPS. For complete details, see Installation Instructions packed with the National Fuel Gas Code ANSI Z223.1. Do not overtighten. Dryer can result. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right...