English Manual
Page 1
... will provide immediate assistance, free of charge to providing complete customer satisfaction. MST CAUTION: Read all safety precautions and instructions in this manual carefully before using this manual for future reference. The trained technicians on our Customer Hot Line will guarantee you . 44, rmor,:e Model No. WLCR95054 Serial No. I 4 ( Serial Number...
... will provide immediate assistance, free of charge to providing complete customer satisfaction. MST CAUTION: Read all safety precautions and instructions in this manual carefully before using this manual for future reference. The trained technicians on our Customer Hot Line will guarantee you . 44, rmor,:e Model No. WLCR95054 Serial No. I 4 ( Serial Number...
English Manual
Page 2
...the location of the packing materials until 6 p.m. The CARDIOGLIDE 950 offers a unique form of the part. The model number is completed. The number in assembly. The second number refers to the quantity used in parenthesis below ), and your safety and benefit, ...found on a decal attached to identify the small parts used in a cleared area and remove the packing materials. Use the part drawings below to the CARDIOGLIDE 950 (see the drawing below each step carefully before using the CARDIOGLIDE 950. For your own phillips screwdriver adjustable wrench 0 and rubber...
...the location of the packing materials until 6 p.m. The CARDIOGLIDE 950 offers a unique form of the part. The model number is completed. The number in assembly. The second number refers to the quantity used in parenthesis below ), and your safety and benefit, ...found on a decal attached to identify the small parts used in a cleared area and remove the packing materials. Use the part drawings below to the CARDIOGLIDE 950 (see the drawing below each step carefully before using the CARDIOGLIDE 950. For your own phillips screwdriver adjustable wrench 0 and rubber...
English Manual
Page 4
..., with the narrow end forward, to the angle shown, and adjust it until the Magnet (27) is a 1/8" gap between the Frame and the Monitor. 1 0.,2,0.. 15 .. Using the included pedal tool, tap a 1/2" Push Nut (30) onto the shaft. Attach the Monitor to the underside of grease to pinch the wire between the...
..., with the narrow end forward, to the angle shown, and adjust it until the Magnet (27) is a 1/8" gap between the Frame and the Monitor. 1 0.,2,0.. 15 .. Using the included pedal tool, tap a 1/2" Push Nut (30) onto the shaft. Attach the Monitor to the underside of grease to pinch the wire between the...
English Manual
Page 5
...Remember t6 keep your feet on the foot pegs rather than the pedals as you exercise. ADJUSTMENT AND OPERATION EXERCISING ON THE CARDIOGLIDE 950 Sit on the seat, place your back straight. Repeat, moving with your heels down- RESISTANCE ADJUSTMENT To vary the intensity of your...through the full range of the Resistance Cylinder (9) can be adjusted. As you have selected. CAUTION: The Resistance Cylinder becomes very hot during use. ward. The arrow on the pedals to prevent them from slipping. CAUTION: To avoid injury, keep your exercise, the resistance of motion...
...Remember t6 keep your feet on the foot pegs rather than the pedals as you exercise. ADJUSTMENT AND OPERATION EXERCISING ON THE CARDIOGLIDE 950 Sit on the seat, place your back straight. Repeat, moving with your heels down- RESISTANCE ADJUSTMENT To vary the intensity of your...through the full range of the Resistance Cylinder (9) can be adjusted. As you have selected. CAUTION: The Resistance Cylinder becomes very hot during use. ward. The arrow on the pedals to prevent them from slipping. CAUTION: To avoid injury, keep your exercise, the resistance of motion...
English Manual
Page 7
... (15) should be replaced. • MAINTENANCE AND TROUBLE-SHOOTING MONITOR CARE Keep the monitor out of direct sunlight or the LCD display may be cleaned using a soft, dry cloth. Remove the #8 x 1/2" Screw (16) from the back cover of the Monitor and remove the back cover. Insert any ...#8 x 3/4" Screw (35) and adjust the position of the Link Arms (4) should be checked. Retighten the #8 x 3/4" Screw. 7 27 15 15 35 27 LUBRICATING THE CARDIOGLIDE 950 The ends of the Reed Switch so that the wire on the Monitor is plugged into the Frame. Apply a few drops of the Monitor. Make...
... (15) should be replaced. • MAINTENANCE AND TROUBLE-SHOOTING MONITOR CARE Keep the monitor out of direct sunlight or the LCD display may be cleaned using a soft, dry cloth. Remove the #8 x 1/2" Screw (16) from the back cover of the Monitor and remove the back cover. Insert any ...#8 x 3/4" Screw (35) and adjust the position of the Link Arms (4) should be checked. Retighten the #8 x 3/4" Screw. 7 27 15 15 35 27 LUBRICATING THE CARDIOGLIDE 950 The ends of the Reed Switch so that the wire on the Monitor is plugged into the Frame. Apply a few drops of the Monitor. Make...
English Manual
Page 8
...body for persons over the age of 35 or persons with pre-existing health problems. EXERCISE INTENSITY To maximize the benefits of exercising, it is used because your heart rate will help you to find your physician. Training zones are essential for successful results. Begin each week, with 5 to.... The proper intensity level can be found by 10 to plan your exercise program. Take a six-second heartbeat count, and multiply the result by using your heart rate as you exercise. For example, if your six-second heartbeat count is 14, your heart rate is 140 beats per minute. (A...
...body for persons over the age of 35 or persons with pre-existing health problems. EXERCISE INTENSITY To maximize the benefits of exercising, it is used because your heart rate will help you to find your physician. Training zones are essential for successful results. Begin each week, with 5 to.... The proper intensity level can be found by 10 to plan your exercise program. Take a six-second heartbeat count, and multiply the result by using your heart rate as you exercise. For example, if your six-second heartbeat count is 14, your heart rate is 140 beats per minute. (A...
English Manual
Page 11
... REPLACEMENT PARTS To order replacement parts, simply call our Customer Service Department toll-free at one of the product (WESLO' CARDIOGLIDE 950). 3. This warranty extends only to replacing or repairing, at ICON's option, the product at one of its ... its authorized service centers with all freight and other transportation charges prepaid, accompanied by sufficient proof of purchase. ICON's obligation under normal use and service conditions, for commercial or rental purposes. LIMITED WARRANTY Icon Health & Fitness, Inc., ("ICON") warrants this manual. This ...
... REPLACEMENT PARTS To order replacement parts, simply call our Customer Service Department toll-free at one of the product (WESLO' CARDIOGLIDE 950). 3. This warranty extends only to replacing or repairing, at ICON's option, the product at one of its ... its authorized service centers with all freight and other transportation charges prepaid, accompanied by sufficient proof of purchase. ICON's obligation under normal use and service conditions, for commercial or rental purposes. LIMITED WARRANTY Icon Health & Fitness, Inc., ("ICON") warrants this manual. This ...