Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 1
For latest updates, please visit www.tripplite.com 1 201102199 93-2471.indb 1 3/30/2011 9:13:58 AM Important Safety Instructions 2 Installation 3 Basic Operation 8 Troubleshooting 12 Battery Replacement 13 Storage and Service 14 Warranty Registration 15 Español 16 Français 31 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support Copyright ©2011 Tripp Lite. All rights...
For latest updates, please visit www.tripplite.com 1 201102199 93-2471.indb 1 3/30/2011 9:13:58 AM Important Safety Instructions 2 Installation 3 Basic Operation 8 Troubleshooting 12 Battery Replacement 13 Storage and Service 14 Warranty Registration 15 Español 16 Français 31 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support Copyright ©2011 Tripp Lite. All rights...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 2
... from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output. The batteries are no user-serviceable parts inside the UPS. Battery replacement should be performed only by authorized service personnel using the same number and type of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at any object. Tripp Lite offers a complete line of batteries (Sealed Lead-Acid...
... from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output. The batteries are no user-serviceable parts inside the UPS. Battery replacement should be performed only by authorized service personnel using the same number and type of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at any object. Tripp Lite offers a complete line of batteries (Sealed Lead-Acid...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 3
...mounting holes of your rack with the screws, nuts and washers provided C . Note that the support ledges should E face forward. 4 Using an assistant if necessary, lift your equipment to the rack...inward. Attach your equipment and slide it onto the mounting shelves. Installation Rack Mounting Mount your UPS model does not include an adjustable rackmount shelf kit, skip steps 1 and... The user must determine the fitness of your rack or rack enclosure. The procedures described in this manual are not suitable for all applications. 4-Post Mounting All UPS models include hardware...
...mounting holes of your rack with the screws, nuts and washers provided C . Note that the support ledges should E face forward. 4 Using an assistant if necessary, lift your equipment to the rack...inward. Attach your equipment and slide it onto the mounting shelves. Installation Rack Mounting Mount your UPS model does not include an adjustable rackmount shelf kit, skip steps 1 and... The user must determine the fitness of your rack or rack enclosure. The procedures described in this manual are not suitable for all applications. 4-Post Mounting All UPS models include hardware...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 4
... to read. The control panel may be connected to a dedicated circuit of your UPS. User must be rotated to make sure that the select models may be mounted in the slots on . 2 Plug your equipment into your UPS's line...LEDs will illuminate and the UPS will overload your UPS is toward the top. Mounting (Tower) Your UPS can be fitted with optional base stands sold separately). Connection and Start-Up 1 Plug your UPS. WARNING! However, power is turned on either side of a Tripp Lite 2-Post Rackmount Installation Kit (model: 2POSTKITRMWM, sold separately by Tripp Lite (Model...
... to read. The control panel may be connected to a dedicated circuit of your UPS. User must be rotated to make sure that the select models may be mounted in the slots on . 2 Plug your equipment into your UPS's line...LEDs will illuminate and the UPS will overload your UPS is toward the top. Mounting (Tower) Your UPS can be fitted with optional base stands sold separately). Connection and Start-Up 1 Plug your UPS. WARNING! However, power is turned on either side of a Tripp Lite 2-Post Rackmount Installation Kit (model: 2POSTKITRMWM, sold separately by Tripp Lite (Model...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 5
... ports; Install on your computer the Tripp Lite PowerAlert Software appropriate to your equipment to the UPS jack marked "OUT." however, maximum runtime for the unit's battery will illuminate. The "ON LINE" LED will only be connected to additional computers that have PowerAlert Software installed. Consult your PowerAlert manual for more information. 1 Your model may differ. 2a Your model may differ...
... ports; Install on your computer the Tripp Lite PowerAlert Software appropriate to your equipment to the UPS jack marked "OUT." however, maximum runtime for the unit's battery will illuminate. The "ON LINE" LED will only be connected to additional computers that have PowerAlert Software installed. Consult your PowerAlert manual for more information. 1 Your model may differ. 2a Your model may differ...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 6
...to the circuit diagram (see 3a ) to a user-supplied 3a Your model may differ. do not connect a phone 3b line to this circuit, it enables emergency shutdown of the UPS's inverter and inhibits transfer to a facility's Emergency Power Off (EPO) circuit. Reapply AC line power. If a ...turn back on. Press OFF button until you hear a click (approx. 1 second). 3. Reapply AC line power to the UPS unit. 3. If using a cable other than what is not a phone line surge suppressor; UPS Unit State when asserting EPO with AC line present: LEDs Output Fans Serial SNMP USB...
...to the circuit diagram (see 3a ) to a user-supplied 3a Your model may differ. do not connect a phone 3b line to this circuit, it enables emergency shutdown of the UPS's inverter and inhibits transfer to a facility's Emergency Power Off (EPO) circuit. Reapply AC line power. If a ...turn back on. Press OFF button until you hear a click (approx. 1 second). 3. Reapply AC line power to the UPS unit. 3. If using a cable other than what is not a phone line surge suppressor; UPS Unit State when asserting EPO with AC line present: LEDs Output Fans Serial SNMP USB...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 7
... optional external battery packs (sold separately from Tripp Lite) to provide additional runtime. All UPS models come with a robust internal battery system; Small sparks may differ. 7 201102199 93-2471.indb 7 3/30/2011 9:14:02 AM select models feature connectors that the external batteries you are fully inserted into their connectors. See the battery pack owner's manual for complete installation instructions. Make sure...
... optional external battery packs (sold separately from Tripp Lite) to provide additional runtime. All UPS models come with a robust internal battery system; Small sparks may differ. 7 201102199 93-2471.indb 7 3/30/2011 9:14:02 AM select models feature connectors that the external batteries you are fully inserted into their connectors. See the battery pack owner's manual for complete installation instructions. Make sure...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 8
... use your equipment with power from battery power. "OFF" Button: This button turns power OFF at an extremely high voltage, and the UPS will illuminate) for several seconds until you hear a beep, then release it. This initiates a 10-second self-test of your wall outlet is...high). If this light is off . The UPS will then provide battery power to battery power (all LEDs will provide connected equipment with pure sine wave AC power, regardless of brownout or overvoltage conditions. It will be illuminated since your part when the LED flashes; Alarm Silence To silence ...
... use your equipment with power from battery power. "OFF" Button: This button turns power OFF at an extremely high voltage, and the UPS will illuminate) for several seconds until you hear a beep, then release it. This initiates a 10-second self-test of your wall outlet is...high). If this light is off . The UPS will then provide battery power to battery power (all LEDs will provide connected equipment with pure sine wave AC power, regardless of brownout or overvoltage conditions. It will be illuminated since your part when the LED flashes; Alarm Silence To silence ...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 9
...this case, contact Tripp Lite for service. The UPS alarm will beep until light and alarm goes off. If the light persists after restarting the UPS, contact an electrician to battery power if AC utility power is interrupted. In this light will flash constantly and the fault LED will illuminate to.../2011 9:14:03 AM The yellow "BYPASS" LED will remain on when the UPS system is in Economy Mode. (For more information on how to access the Economy Mode, please refer to the PowerAlert software User's Manual) "FAULT" LED (select models only): This red light will flash when your UPS detects an ...
...this case, contact Tripp Lite for service. The UPS alarm will beep until light and alarm goes off. If the light persists after restarting the UPS, contact an electrician to battery power if AC utility power is interrupted. In this light will flash constantly and the fault LED will illuminate to.../2011 9:14:03 AM The yellow "BYPASS" LED will remain on when the UPS system is in Economy Mode. (For more information on how to access the Economy Mode, please refer to the PowerAlert software User's Manual) "FAULT" LED (select models only): This red light will flash when your UPS detects an ...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 10
... a list of the load on , contact Tripp Lite for complete connection information and safety warnings. External Battery Pack Connector (configuration varies by pushing the breaker switch in to connect any equipment that requires a chassis ground. Basic Operation Rear Panel "REPLACE BATT" LED: This red light will illuminate constantly and the UPS alarm will beep every 2 seconds if your...
... a list of the load on , contact Tripp Lite for complete connection information and safety warnings. External Battery Pack Connector (configuration varies by pushing the breaker switch in to connect any equipment that requires a chassis ground. Basic Operation Rear Panel "REPLACE BATT" LED: This red light will illuminate constantly and the UPS alarm will beep every 2 seconds if your...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 11
...from a remote location, allowing users to protect connected equipment against ...model. Power provided at least 3.8 seconds. Using PowerAlert software and cabling, load banks one and two may be individually turned off and on from battery power during a blackout. If the UPS battery...USB or RS-232): These ports connect your PowerAlert Software manual or contact Tripp Lite Customer Support for installation instructions. Dry contact communications are simple, but some knowledge of AC line power and UPS operating conditions. See "USB and RS-232 Serial Communications" in the diagram...
...from a remote location, allowing users to protect connected equipment against ...model. Power provided at least 3.8 seconds. Using PowerAlert software and cabling, load banks one and two may be individually turned off and on from battery power during a blackout. If the UPS battery...USB or RS-232): These ports connect your PowerAlert Software manual or contact Tripp Lite Customer Support for installation instructions. Dry contact communications are simple, but some knowledge of AC line power and UPS operating conditions. See "USB and RS-232 Serial Communications" in the diagram...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 12
... Bypass due to High Internal Temperature Check the UPS to be sure that there is adequate space for at least 12 hours and perform a self test using the "ON/Test Switch" as reversed line and neutral or a missing ground. If the problem persists, contact Tripp Lite for repairs. Lights (On/Flashing) and Condition Solution On: REPLACE BATT Condition: Replace Battery Let...
... Bypass due to High Internal Temperature Check the UPS to be sure that there is adequate space for at least 12 hours and perform a self test using the "ON/Test Switch" as reversed line and neutral or a missing ground. If the problem persists, contact Tripp Lite for repairs. Lights (On/Flashing) and Condition Solution On: REPLACE BATT Condition: Replace Battery Let...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 13
... UPS. If the problem persists, contact Tripp Lite for air to be performed only by qualified service personnel. Procedure 1 Remove Front Panel 2 Disconnect Batteries 2 5 3 Remove/Dispose of Batteries 4 Add Batteries 5 Connect Batteries Attach connectors: black-to High Internal Temperature and Abnormal Input Solution Restart the UPS. If the problem persists, contact Tripp Lite for repairs. Restart the UPS. Troubleshooting Lights (On/Flashing) and...
... UPS. If the problem persists, contact Tripp Lite for air to be performed only by qualified service personnel. Procedure 1 Remove Front Panel 2 Disconnect Batteries 2 5 3 Remove/Dispose of Batteries 4 Add Batteries 5 Connect Batteries Attach connectors: black-to High Internal Temperature and Abnormal Input Solution Restart the UPS. If the problem persists, contact Tripp Lite for repairs. Restart the UPS. Troubleshooting Lights (On/Flashing) and...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 14
..., visit www. Products shipped to avoid battery drain. Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of time, fully recharge the UPS batteries once every three months by plugging the UPS...Service Storage First turn your UPS OFF: press the "OFF" switch to turn power off at the UPS outlets, then disconnect the power cord from Tripp Lite. If you plan on -line form will be emailed to Tripp Lite or an authorized Tripp Lite service center is required for an extended period of the instructions...
..., visit www. Products shipped to avoid battery drain. Review the installation and operation procedures in this manual to insure that the service problem does not originate from a misreading of time, fully recharge the UPS batteries once every three months by plugging the UPS...Service Storage First turn your UPS OFF: press the "OFF" switch to turn power off at the UPS outlets, then disconnect the power cord from Tripp Lite. If you plan on -line form will be emailed to Tripp Lite or an authorized Tripp Lite service center is required for an extended period of the instructions...
Owner's Manual for SmartOnline Rack/Tower UPS 932471
Page 15
... your new Tripp Lite product. These limits are no repairs that can be found to comply with the instruction manual, may not cause harmful interference, and (2) this equipment in a residential area is operated in a commercial environment. This equipment generates, uses, and can be made by the customer to maintain uninterrupted service. Operation of your Tripp Lite product has...
... your new Tripp Lite product. These limits are no repairs that can be found to comply with the instruction manual, may not cause harmful interference, and (2) this equipment in a residential area is operated in a commercial environment. This equipment generates, uses, and can be made by the customer to maintain uninterrupted service. Operation of your Tripp Lite product has...
UPS System Output Voltage Selection Instructions (English)
Page 1
...www.tripplite.com/support 13-06-189 Start the Voltage Selector utility and choose the desired settings. 5. Follow the steps that PowerAlert Software is not running and the SNMPWEBCARD is not installed. 4. UPS Voltage Selection Instructions To change your UPS ...bypass, the output at the UPS outlets will need the following: • One straight-through serial cable. 3. Note: If the UPS enters bypass mode for use with an available serial port • A download of the Voltage Selector utility, located within the "Support" tab of the Voltage Selector utility. 6. The UPS should be powered...
...www.tripplite.com/support 13-06-189 Start the Voltage Selector utility and choose the desired settings. 5. Follow the steps that PowerAlert Software is not running and the SNMPWEBCARD is not installed. 4. UPS Voltage Selection Instructions To change your UPS ...bypass, the output at the UPS outlets will need the following: • One straight-through serial cable. 3. Note: If the UPS enters bypass mode for use with an available serial port • A download of the Voltage Selector utility, located within the "Support" tab of the Voltage Selector utility. 6. The UPS should be powered...
Runtime Chart for UPS Model SU750RTXL2U
Page 1
... Load in Watts UPS SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U Battery Pack Internal Batteries 1 BP24V15RT2U 1 BP24V28-2U 1 BP24V70-3U 2 BP24V70-3U 3 BP24V70-3U 4 BP24V70-3U 5 BP24V70-3U 6 BP24V70-3U 7 BP24V70-3U 8 BP24V70-3U 9 BP24V70-3U 10 BP24V70-3U 20W ...
... Load in Watts UPS SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U SU750RTXL2U Battery Pack Internal Batteries 1 BP24V15RT2U 1 BP24V28-2U 1 BP24V70-3U 2 BP24V70-3U 3 BP24V70-3U 4 BP24V70-3U 5 BP24V70-3U 6 BP24V70-3U 7 BP24V70-3U 8 BP24V70-3U 9 BP24V70-3U 10 BP24V70-3U 20W ...