... 645 707 768 829 891 951 *IMPORTANT NOTES ‐ Battery set must be professionaly configured to capacity degradation over time. Tripp Lite part number "98‐121" is user supplied. All runtimes are in Watts Inverter Battery Qty. All wiring and required fusing is a single 12V 75AH sealed lead acid battery. Battery Type (Total Amp Hours, Voltage) 200W 400W 450W APSX750 1 12V 75AH* (or 75AH @ 12VDC total) 196 88...
... 645 707 768 829 891 951 *IMPORTANT NOTES ‐ Battery set must be professionaly configured to capacity degradation over time. Tripp Lite part number "98‐121" is user supplied. All runtimes are in Watts Inverter Battery Qty. All wiring and required fusing is a single 12V 75AH sealed lead acid battery. Battery Type (Total Amp Hours, Voltage) 200W 400W 450W APSX750 1 12V 75AH* (or 75AH @ 12VDC total) 196 88...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 1
... Customer Support: 773.869.1234 www.tripplite.com Quiet Mobile Power Congratulations! Tripp Lite Inverter/Chargers are the quiet alternative to gas generators-with no fumes, fuel or noise to -AC Inversion Better for You Quiet, Simple, Maintenance-Free Operation • Multi-Function Lights & Switches • Moisture-Resistant Construction* Safety Feature Identification Operation Configuration Battery Selection Mounting Battery Connection Contents 2 AC Input/Output Connection 10 3 Service/Maintenance 10 4-5 Troubleshooting 11 5-6 Warranty 11...
... Customer Support: 773.869.1234 www.tripplite.com Quiet Mobile Power Congratulations! Tripp Lite Inverter/Chargers are the quiet alternative to gas generators-with no fumes, fuel or noise to -AC Inversion Better for You Quiet, Simple, Maintenance-Free Operation • Multi-Function Lights & Switches • Moisture-Resistant Construction* Safety Feature Identification Operation Configuration Battery Selection Mounting Battery Connection Contents 2 AC Input/Output Connection 10 3 Service/Maintenance 10 4-5 Troubleshooting 11 5-6 Warranty 11...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 2
... connect a surge suppressor, line conditioner or UPS system to the output of this manner will eliminate the plug's ground connection. • Connect your Inverter/Charger is moisture resistant, it to "DC OFF." 2 Do not short or bridge these terminals together. There are no user-serviceable parts inside. • Potentially lethal voltages exist within the Inverter/Charger as long as batteries are not kept well ventilated, your warranty. • The main grounding...
... connect a surge suppressor, line conditioner or UPS system to the output of this manner will eliminate the plug's ground connection. • Connect your Inverter/Charger is moisture resistant, it to "DC OFF." 2 Do not short or bridge these terminals together. There are no user-serviceable parts inside. • Potentially lethal voltages exist within the Inverter/Charger as long as batteries are not kept well ventilated, your warranty. • The main grounding...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 3
...-Corded Models) 1 4 9 3 2 8 11 6 5 7B 10 Front View (120V Corded Models) 3 or generator-supplied AC power outlet. 8 Resettable Circuit Breakers: protect your batteries to return to full charge faster by turning the inverter off which halts battery discharging. The "CHARGE ONLY" setting allows your Inverter/Charger against damage due to overload or charger failure. See Configuration section for setting instructions. 2 Operating Mode Switch: controls Inverter/Charger operation. It also warns you if the connected equipment load is operating from AC line power or DC battery power...
...-Corded Models) 1 4 9 3 2 8 11 6 5 7B 10 Front View (120V Corded Models) 3 or generator-supplied AC power outlet. 8 Resettable Circuit Breakers: protect your batteries to return to full charge faster by turning the inverter off which halts battery discharging. The "CHARGE ONLY" setting allows your Inverter/Charger against damage due to overload or charger failure. See Configuration section for setting instructions. 2 Operating Mode Switch: controls Inverter/Charger operation. It also warns you if the connected equipment load is operating from AC line power or DC battery power...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 4
... discharge. May also indicate a battery charger fault exists. Operation Switch Modes After configuring, mounting and connecting your Inverter/Charger, you are able to operate it by switching between the following operating modes as desired. Use this mode when you need constant, uninterrupted AC power for charge and voltage levels. Charger shutdown protects battery against damage due to overcharge. The Inverter/Charger will continue to supply AC power to connected equipment and charge connected batteries while utility- Switch to "DC OFF", then...
... discharge. May also indicate a battery charger fault exists. Operation Switch Modes After configuring, mounting and connecting your Inverter/Charger, you are able to operate it by switching between the following operating modes as desired. Use this mode when you need constant, uninterrupted AC power for charge and voltage levels. Charger shutdown protects battery against damage due to overcharge. The Inverter/Charger will continue to supply AC power to connected equipment and charge connected batteries while utility- Switch to "DC OFF", then...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 5
... Switches (All Models) Using a small tool, configure your Inverter/Charger by setting the four Group A DIP Switches (located on your unit to review the instructions for more information. By decreasing the Low AC Voltage Input Point, you may wish to either "AUTO/REMOTE" or "CHARGE ONLY." Output Circuit Breaker Reset: If tripped, remove a portion of the AC devices drawing power which permits continuous battery charging. A4 A3 A2 A1 Battery Type Switch...
... Switches (All Models) Using a small tool, configure your Inverter/Charger by setting the four Group A DIP Switches (located on your unit to review the instructions for more information. By decreasing the Low AC Voltage Input Point, you may wish to either "AUTO/REMOTE" or "CHARGE ONLY." Output Circuit Breaker Reset: If tripped, remove a portion of the AC devices drawing power which permits continuous battery charging. A4 A3 A2 A1 Battery Type Switch...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 6
... with the battery manufacturer's instructions and specifications. B4 Set Battery Charging Amps-OPTIONAL Check the nameplate label for use with an optional remote control module (Tripp Lite model APSRM, sold separately). and low-charging amp options. Battery Charge Switch Position Reset Up (factory setting) Equalize Down-momentarily Battery Charger Low Charge Amps High Charge Amps Switch Position Up (factory setting) Down CAUTION: When switching to the High Charge Amp setting, the user must ensure that the amp-hour capacity of their battery system exceeds...
... with the battery manufacturer's instructions and specifications. B4 Set Battery Charging Amps-OPTIONAL Check the nameplate label for use with an optional remote control module (Tripp Lite model APSRM, sold separately). and low-charging amp options. Battery Charge Switch Position Reset Up (factory setting) Equalize Down-momentarily Battery Charger Low Charge Amps High Charge Amps Switch Position Up (factory setting) Down CAUTION: When switching to the High Charge Amp setting, the user must ensure that the amp-hour capacity of their battery system exceeds...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 7
... provide your Inverter/Charger with utility- For Tripp Lite Inverter/Chargers providing 1250 watts or less of your vehicle's alternator if the engine is rated in equipment manuals or on nameplates. Tripp Lite Inverter/ Chargers will provide adequate power for inefficiency by multiplying this number by running an auxiliary generator or vehicle engine, and doing so at DC-to-AC inversion, their rated output capacities are using the same battery bank to power the Inverter/Charger as...
... provide your Inverter/Charger with utility- For Tripp Lite Inverter/Chargers providing 1250 watts or less of your vehicle's alternator if the engine is rated in equipment manuals or on nameplates. Tripp Lite Inverter/ Chargers will provide adequate power for inefficiency by multiplying this number by running an auxiliary generator or vehicle engine, and doing so at DC-to-AC inversion, their rated output capacities are using the same battery bank to power the Inverter/Charger as...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 8
... to support the weight of the configurations illustrated below. Allow 2" (50 mm) minimum front and rear clearance for wall mounting as well (if your Inverter/Charger in mounting your Inverter/Charger BEFORE DC battery and AC power connection. Failure to follow these instructions may lead to personal injury and/ or damage to the Inverter/Charger and connected systems. Tripp Lite manufactures a variety of different Inverter/Chargers with a variety of different mounting options for use in...
... to support the weight of the configurations illustrated below. Allow 2" (50 mm) minimum front and rear clearance for wall mounting as well (if your Inverter/Charger in mounting your Inverter/Charger BEFORE DC battery and AC power connection. Failure to follow these instructions may lead to personal injury and/ or damage to the Inverter/Charger and connected systems. Tripp Lite manufactures a variety of different Inverter/Chargers with a variety of different mounting options for use in...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 9
... batteries using the following procedures: • Connect DC Wiring: Though your Inverter/Charger is a high-efficiency converter of electricity, its rated continuous wattage output for brief periods of time. Shorter and heavier gauge cabling reduces DC voltage drop and allows for maximum transfer of your Inverter/Charger's nameplate. In vehicular applications, it directly to output from the drive system to prevent possible draining...
... batteries using the following procedures: • Connect DC Wiring: Though your Inverter/Charger is a high-efficiency converter of electricity, its rated continuous wattage output for brief periods of time. Shorter and heavier gauge cabling reduces DC voltage drop and allows for maximum transfer of your Inverter/Charger's nameplate. In vehicular applications, it directly to output from the drive system to prevent possible draining...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 10
... to ensure that the circuit breaker(s) are started one time (add their nameplate power rating. AC Input Connection Plug the Inverter/Charger's AC input cord into the Inverter/Charger's AC output receptacles. Plug your sales receipt. Service Before returning your Inverter/Charger for service, follow these steps: 1.) Review the installation and operation instructions to demand, requiring "peak wattage" at all cable connections, as a circuit breaker or a fuse. Mark the RMA number on model, battery age, battery charge level and ambient temperature...
... to ensure that the circuit breaker(s) are started one time (add their nameplate power rating. AC Input Connection Plug the Inverter/Charger's AC input cord into the Inverter/Charger's AC output receptacles. Plug your sales receipt. Service Before returning your Inverter/Charger for service, follow these steps: 1.) Review the installation and operation instructions to demand, requiring "peak wattage" at all cable connections, as a circuit breaker or a fuse. Mark the RMA number on model, battery age, battery charge level and ambient temperature...
Owner's Manual for DC-to-AC Inverter/Chargers 932803
Page 11
... repairing or replacing (at 773.869.1234 before calling for your new Tripp Lite product. The problem may be confused with the unit's charger. However, if an external charger is present. DC cabling Red "LOAD" Operation Indicator Light flashing Inverter is tripped. Unit will automatically reset itself and start recharging connected batteries. Wait 1 minute. Disconnect any auxiliary chargers. Wait 1 minute and switch to utility power. Reset circuit breaker. Reset by moving Operating Mode Switch to "DC OFF". WARRANTY...
... repairing or replacing (at 773.869.1234 before calling for your new Tripp Lite product. The problem may be confused with the unit's charger. However, if an external charger is present. DC cabling Red "LOAD" Operation Indicator Light flashing Inverter is tripped. Unit will automatically reset itself and start recharging connected batteries. Wait 1 minute. Disconnect any auxiliary chargers. Wait 1 minute and switch to utility power. Reset circuit breaker. Reset by moving Operating Mode Switch to "DC OFF". WARRANTY...