Distance From Cooking Surface The installation height ranges from heat if a THERMADOR PROFESSIONAL® series range or rangetop is operated with multiple burners at high settings under a hood that is installed at minimum clearances. Model Weight VCIN36JP 60 lb (27.22 kg) VCIN48JP 73 lb (33.11 kg) VCIN54JP 82 lb (...37.20 kg) VCIB36JP 96 lb (43.54 kg) VCIB48JP 111 lb (50.35 kg) VCIB54JP 122 lb (55.34 kg) IMPORTANT: The supplied weights address only the ventilation unit...
Distance From Cooking Surface The installation height ranges from heat if a THERMADOR PROFESSIONAL® series range or rangetop is operated with multiple burners at high settings under a hood that is installed at minimum clearances. Model Weight VCIN36JP 60 lb (27.22 kg) VCIN48JP 73 lb (33.11 kg) VCIN54JP 82 lb (...37.20 kg) VCIB36JP 96 lb (43.54 kg) VCIB48JP 111 lb (50.35 kg) VCIB54JP 122 lb (55.34 kg) IMPORTANT: The supplied weights address only the ventilation unit...
Installation Instructions
Page 20
... housing in accordance with the dimensions noted in Figure 20 thru Figure 24. Preparing VCINxxJP Housing Framework The unit must be sure to include the weight of Hood 17/8" (47mm) 23" (584mm) 11/8" (29mm) 3 3/16" (81mm) A 77/8 " (200mm) 10¼" (260mm) 23/8" (86mm) 17/8 " (48mm) Diameter ...clearance holes for the housing support system, be mounted to junction box Figure 20: Transition and Conduit Cutout Dimensions English 18 Model A VCIN36JP VCIN48JP VCIN54JP 14 3/16" (360 mm) 19 13/16" (503 mm) 22 13/16" (579 mm) Back of Trim Back of the ventilation ...
... housing in accordance with the dimensions noted in Figure 20 thru Figure 24. Preparing VCINxxJP Housing Framework The unit must be sure to include the weight of Hood 17/8" (47mm) 23" (584mm) 11/8" (29mm) 3 3/16" (81mm) A 77/8 " (200mm) 10¼" (260mm) 23/8" (86mm) 17/8 " (48mm) Diameter ...clearance holes for the housing support system, be mounted to junction box Figure 20: Transition and Conduit Cutout Dimensions English 18 Model A VCIN36JP VCIN48JP VCIN54JP 14 3/16" (360 mm) 19 13/16" (503 mm) 22 13/16" (579 mm) Back of Trim Back of the ventilation ...
Installation Instructions
Page 25
.../16" (579 mm) Back of Liner Back of the ventilation unit. See "Installation Preparation" on page 6 for unit weight by model. Preparing VCIBxxJP Housing Framework The unit must be sure to include the weight of Hood 3 3/16" (81mm) 23" (584mm) 11/8" (29mm) 33/16" (81mm) A 77/8" (200mm) 10¼" (260mm) 23/8" (86mm...
.../16" (579 mm) Back of Liner Back of the ventilation unit. See "Installation Preparation" on page 6 for unit weight by model. Preparing VCIBxxJP Housing Framework The unit must be sure to include the weight of Hood 3 3/16" (81mm) 23" (584mm) 11/8" (29mm) 33/16" (81mm) A 77/8" (200mm) 10¼" (260mm) 23/8" (86mm...