TL-SG105E V1 Datasheet
Page 2
...TP-LINK TECHNOLOGIES CO., LTD. Datasheet Layer 2 Features IGMP Snooping Link Aggregation Port Mirroring Cable Test Loop Prevention VLAN 32 VLANs MTU/Port/Tag VLAN Quality of Service Port Based/802.1p Based priority 4 priority queues Rate Limit Storm Control Green Technology Saving power 75% Recyclable packaging material Easy Smart Con guration Utility Central Management Friendly User Interface 24 / 7 Global technical support Details:http://www.tp-link.com/ support/Localesupport.asp German/Austrian/Swiss users are not included www.tp-link.com TP-LINK 5-Port Gigabit Easy Smart Switch TL-SG105E...
...TP-LINK TECHNOLOGIES CO., LTD. Datasheet Layer 2 Features IGMP Snooping Link Aggregation Port Mirroring Cable Test Loop Prevention VLAN 32 VLANs MTU/Port/Tag VLAN Quality of Service Port Based/802.1p Based priority 4 priority queues Rate Limit Storm Control Green Technology Saving power 75% Recyclable packaging material Easy Smart Con guration Utility Central Management Friendly User Interface 24 / 7 Global technical support Details:http://www.tp-link.com/ support/Localesupport.asp German/Austrian/Swiss users are not included www.tp-link.com TP-LINK 5-Port Gigabit Easy Smart Switch TL-SG105E...
TL-SG105E V1 Datasheet
Page 3
... RJ45 Ports Power Supply Fan Quantity Certi cation Dimensions (W x D x H) Environment Performance Switch Capacity Forwarding Rate Mac Address Table Packet Bu er Memory Jumbo Frame TL-SG105E 5 100-240VAC, 50/60Hz Fanless CE, FCC 3.9 x 3.9 x 1.0 in. (100 x 98 x 25 mm) Operating Temperature: 0℃~40℃(32℉~104℉); Storage Humidity: 5%~90% non-condensing 10Gbps 7.4Mpps 8k 2Mb 16KB Software Features L2 Switching Features IGMP Snooping IGMP Snooping v1/v2/v3 Supports 128 Groups Link Aggregation Support static link aggregation 1 aggregation...
... RJ45 Ports Power Supply Fan Quantity Certi cation Dimensions (W x D x H) Environment Performance Switch Capacity Forwarding Rate Mac Address Table Packet Bu er Memory Jumbo Frame TL-SG105E 5 100-240VAC, 50/60Hz Fanless CE, FCC 3.9 x 3.9 x 1.0 in. (100 x 98 x 25 mm) Operating Temperature: 0℃~40℃(32℉~104℉); Storage Humidity: 5%~90% non-condensing 10Gbps 7.4Mpps 8k 2Mb 16KB Software Features L2 Switching Features IGMP Snooping IGMP Snooping v1/v2/v3 Supports 128 Groups Link Aggregation Support static link aggregation 1 aggregation...
TL-SG105E V1 UG
Page 2
... Getting Started 4 2.1 Introduction...4 2.2 Install the Easy Smart Configuration Utility 4 2.3 Switch Discovery ...8 2.4 Switch Settings ...8 2.5 Refresh ...9 2.6 Utility Features Overview 10 2.7 Uninstall the Utility 12 Chapter 3 System 14 3.1 System Info...14 3.2 IP Setting ...15 3.3 User Account ...15 3.4 Backup and Restore 16 3.5 System Reboot ...17 3.6 System Reset ...17 3.7 Firmware Upgrade 18 Chapter 4 Switching 19 4.1 Port Setting...19 4.2 IGMP Snooping ...20 4.3 Port Trunk...21 Chapter 5 Monitoring 23 5.1 Port Statistics...23 5.2 Port Mirror...24 5.3 Cable Test ...25 5.4 Loop...
... Getting Started 4 2.1 Introduction...4 2.2 Install the Easy Smart Configuration Utility 4 2.3 Switch Discovery ...8 2.4 Switch Settings ...8 2.5 Refresh ...9 2.6 Utility Features Overview 10 2.7 Uninstall the Utility 12 Chapter 3 System 14 3.1 System Info...14 3.2 IP Setting ...15 3.3 User Account ...15 3.4 Backup and Restore 16 3.5 System Reboot ...17 3.6 System Reset ...17 3.7 Firmware Upgrade 18 Chapter 4 Switching 19 4.1 Port Setting...19 4.2 IGMP Snooping ...20 4.3 Port Trunk...21 Chapter 5 Monitoring 23 5.1 Port Statistics...23 5.2 Port Mirror...24 5.3 Cable Test ...25 5.4 Loop...
TL-SG105E V1 UG
Page 5
...the username and password for users to the default. z System Reboot: Reboot your switch. This module is used to configure the basic functions of each port, including the port status, speed, duplex mode and flow control. z Port Statistics: View the statistic information of the switch. z Backup and Restore: Save the current configuration file to your computer or download a backup configuration file to your switch. z System Reset: Reset the switch to login the Web management page. This module is used to monitor the traffic information of the switch. z Port Trunk: Configure...
...the username and password for users to the default. z System Reboot: Reboot your switch. This module is used to configure the basic functions of each port, including the port status, speed, duplex mode and flow control. z Port Statistics: View the statistic information of the switch. z Backup and Restore: Save the current configuration file to your computer or download a backup configuration file to your switch. z System Reset: Reset the switch to login the Web management page. This module is used to monitor the traffic information of the switch. z Port Trunk: Configure...
TL-SG105E V1 UG
Page 10
Please wait for a while. Figure 2-5 Setup Status f. Figure 2-6 InstallShield Wizard Complete 3. Click Finish to complete the installation on the computer desktop. 7 The installation process creates a TP-LINK subdirectory under the \Program Files directory on your computer, copies the utility program into the \Program Files\TP-LINK\Easy Smart Configuration Utility directory, and places a utility icon on the following screen. The InstallShield Wizard is installing Easy Smart Configuration Utility shown as the following screen. Easy Smart Configuration Utility User Guide e.
Please wait for a while. Figure 2-5 Setup Status f. Figure 2-6 InstallShield Wizard Complete 3. Click Finish to complete the installation on the computer desktop. 7 The installation process creates a TP-LINK subdirectory under the \Program Files directory on your computer, copies the utility program into the \Program Files\TP-LINK\Easy Smart Configuration Utility directory, and places a utility icon on the following screen. The InstallShield Wizard is installing Easy Smart Configuration Utility shown as the following screen. Easy Smart Configuration Utility User Guide e.
TL-SG105E V1 UG
Page 11
Figure 2-7 Main Page Click Help in the left bottom to configure or display its status. Figure 2-8 Discovered Switch 8 The discovered switches are listed as below. Note: The maximum number of the discovered switches is launched, it immediately searches the network for more help. Easy Smart Configuration Utility User Guide 2.3 Switch Discovery When the utility is 30. 2.4 Switch Settings You can select a switch and click to access the TP-LINK support website for TP-LINK Easy Smart Switches.
Figure 2-7 Main Page Click Help in the left bottom to configure or display its status. Figure 2-8 Discovered Switch 8 The discovered switches are listed as below. Note: The maximum number of the discovered switches is launched, it immediately searches the network for more help. Easy Smart Configuration Utility User Guide 2.3 Switch Discovery When the utility is 30. 2.4 Switch Settings You can select a switch and click to access the TP-LINK support website for TP-LINK Easy Smart Switches.
TL-SG105E V1 UG
Page 12
... management page and configure the switch. Clicking Apply can configure the switch's Device Description, DHCP Setting, IP Address, Subnet Mask and Default Gateway on this page. If you to restart the switch discovering process. 9 The login User Name and Password are both admin. Therefore, it needs to set the switch IP Address in the same subnet with host IP Address, it can be shown as below: Easy Smart Configuration Utility User Guide Figure 2-9 Switch Setting...
... management page and configure the switch. Clicking Apply can configure the switch's Device Description, DHCP Setting, IP Address, Subnet Mask and Default Gateway on this page. If you to restart the switch discovering process. 9 The login User Name and Password are both admin. Therefore, it needs to set the switch IP Address in the same subnet with host IP Address, it can be shown as below: Easy Smart Configuration Utility User Guide Figure 2-9 Switch Setting...
TL-SG105E V1 UG
Page 17
... configuration of the switch, including seven submenus: System Info, IP Setting, User Account, Backup and Restore, System Reboot, System Reset and Firmware Upgrade. 3.1 System Info On this page you can view the system information and define the device description. Displays the subnet mask of the switch. Displays the MAC address of the switch. Displays the installed software version number. Displays the system IP address of the switch. Displays the default gateway of the switch...
... configuration of the switch, including seven submenus: System Info, IP Setting, User Account, Backup and Restore, System Reboot, System Reset and Firmware Upgrade. 3.1 System Info On this page you can view the system information and define the device description. Displays the subnet mask of the switch. Displays the MAC address of the switch. Displays the installed software version number. Displays the system IP address of the switch. Displays the default gateway of the switch...
TL-SG105E V1 UG
Page 18
... Default Gateway: Enter the default gateway of the switch. Easy Smart Configuration Utility User Guide 3.2 IP Setting Each device in order to obtain an IP address from the DHCP Server automatically; If DHCP setting is disabled. By default, the switch uses 255.255.255.0 as the subnet mask. The switch supports the DHCP mode to refuse illegal users. IP Address: Enter the system IP of the switch. 3.3 User Account On this screen: ¾ System IP Address Setting DHCP Setting: Enable or disable the DHCP...
... Default Gateway: Enter the default gateway of the switch. Easy Smart Configuration Utility User Guide 3.2 IP Setting Each device in order to obtain an IP address from the DHCP Server automatically; If DHCP setting is disabled. By default, the switch uses 255.255.255.0 as the subnet mask. The switch supports the DHCP mode to refuse illegal users. IP Address: Enter the system IP of the switch. 3.3 User Account On this screen: ¾ System IP Address Setting DHCP Setting: Enable or disable the DHCP...
TL-SG105E V1 UG
Page 19
... System→Backup and Restore to this page you can download the current configuration and save it as a file to your computer, or upload a backup configuration file to restore your switch to load the following entries are displayed on this screen: ¾ System User Setting User Name: Create a name for administrator's login. Password: Type in the old password. The default username/password is admin/admin. 3.4 Backup and Restore On this previous configuration. Old Password: Type in a new password for administrator...
... System→Backup and Restore to this page you can download the current configuration and save it as a file to your computer, or upload a backup configuration file to restore your switch to load the following entries are displayed on this screen: ¾ System User Setting User Name: Create a name for administrator's login. Password: Type in the old password. The default username/password is admin/admin. 3.4 Backup and Restore On this previous configuration. Old Password: Type in a new password for administrator...
TL-SG105E V1 UG
Page 21
... reset, the switch will be reset to the default and all the settings will reboot automatically. 5. Go to http://www.tp-link.com to backup the configuration before upgrading. To avoid damage, please don't turn off the device while upgrading. 4. Don't interrupt the upgrade. 2. After upgrading, the device will be cleared. 3.7 Firmware Upgrade The switch system can be upgraded via this management page. You are suggested to download the updated firmware. Return to upgrade. 3. Figure 3-6 System Reset...
... reset, the switch will be reset to the default and all the settings will reboot automatically. 5. Go to http://www.tp-link.com to backup the configuration before upgrading. To avoid damage, please don't turn off the device while upgrading. 4. Don't interrupt the upgrade. 2. After upgrading, the device will be cleared. 3.7 Firmware Upgrade The switch system can be upgraded via this management page. You are suggested to download the updated firmware. Return to upgrade. 3. Figure 3-6 System Reset...
TL-SG105E V1 UG
Page 23
... and an IGMP host. Speed and Duplex: Flow Control: LAG: Easy Smart Configuration Utility User Guide Config: Select the Speed and Duplex mode for dynamic registration of the port. Displays the LAG number which is off by congestion. IGMP Snooping allows the switch to Enable/Disable the Flow Control feature. Choose the menu Switching→IGMP Snooping to avoid the packet loss caused by default. On this page you can not be determined by auto-negotiation. By managing and controlling the multicast address table, the...
... and an IGMP host. Speed and Duplex: Flow Control: LAG: Easy Smart Configuration Utility User Guide Config: Select the Speed and Duplex mode for dynamic registration of the port. Displays the LAG number which is off by congestion. IGMP Snooping allows the switch to Enable/Disable the Flow Control feature. Choose the menu Switching→IGMP Snooping to avoid the packet loss caused by default. On this page you can not be determined by auto-negotiation. By managing and controlling the multicast address table, the...
TL-SG105E V1 UG
Page 24
.... Ports: Displays the forwarding port list of the multicast group. 4.3 Port Trunk Port trunk is the sum of bandwidth of its member ports should be set as that of the first member port in a trunk group, their default setting of the trunk setting will be configured the same as mirroring port. If the port trunk is needed, you are some rules on the switch. ¾ Multicast IP Table IP Address: Displays the multicast IP address. Change of Port setting (Speed and Duplex, Flow Control), QoS will...
.... Ports: Displays the forwarding port list of the multicast group. 4.3 Port Trunk Port trunk is the sum of bandwidth of its member ports should be set as that of the first member port in a trunk group, their default setting of the trunk setting will be configured the same as mirroring port. If the port trunk is needed, you are some rules on the switch. ¾ Multicast IP Table IP Address: Displays the multicast IP address. Change of Port setting (Speed and Duplex, Flow Control), QoS will...
TL-SG105E V1 UG
Page 27
... this screen: ¾ Port Mirror Port Mirror Status: Enable or disable the port mirror feature of incoming and outgoing packets from the drop-down list as the mirroring port. ¾ Mirrored Port Mirrored Ports: Click the port icon to select the corresponding port as mirrored port, it supports ingress and egress monitoring; Note: 1. Usually, the mirroring port is connected to a data diagnosis device, which is to monitor and mirror network traffic by forwarding copies of the specified port. The trunk member can span the multiple VLANs. 24
... this screen: ¾ Port Mirror Port Mirror Status: Enable or disable the port mirror feature of incoming and outgoing packets from the drop-down list as the mirroring port. ¾ Mirrored Port Mirrored Ports: Click the port icon to select the corresponding port as mirrored port, it supports ingress and egress monitoring; Note: 1. Usually, the mirroring port is connected to a data diagnosis device, which is to monitor and mirror network traffic by forwarding copies of the specified port. The trunk member can span the multiple VLANs. 24
TL-SG105E V1 UG
Page 29
Figure 5-4 Loop Prevention Setting The following entries are displayed on this screen: ¾ Loop Prevention Setting Loop Prevention Status: Allows you to load the following page. When a loop is detected, the switch will block the corresponding port automatically. Easy Smart Configuration Utility User Guide 5.4 Loop Prevention With loop prevention feature enabled, the switch can detect loops using loop detection packets. Choose the menu Monitoring→Loop Prevention to enable or disable loop prevention function globally. Return to CONTENTS 26
Figure 5-4 Loop Prevention Setting The following entries are displayed on this screen: ¾ Loop Prevention Setting Loop Prevention Status: Allows you to load the following page. When a loop is detected, the switch will block the corresponding port automatically. Easy Smart Configuration Utility User Guide 5.4 Loop Prevention With loop prevention feature enabled, the switch can detect loops using loop detection packets. Choose the menu Monitoring→Loop Prevention to enable or disable loop prevention function globally. Return to CONTENTS 26
TL-SG105E V1 UG
Page 31
... specific hosts. IEEE 802.1Q Tag VLAN is reduced. VLAN can communicate with any other port but other ports cannot communicate with each of the other ports. In this User Guide, the tagged packet refers to the packet with each other ports in the switch: 1. The switch works at the data link layer in OSI model and it belongs to identify packets of VLAN modes supported in the switch, so the uplink port can be used to change...
... specific hosts. IEEE 802.1Q Tag VLAN is reduced. VLAN can communicate with any other port but other ports cannot communicate with each of the other ports. In this User Guide, the tagged packet refers to the packet with each other ports in the switch: 1. The switch works at the data link layer in OSI model and it belongs to identify packets of VLAN modes supported in the switch, so the uplink port can be used to change...
TL-SG105E V1 UG
Page 33
... Config Port Based VLAN Configuration: Enable or disable Port Based VLAN mode. ¾ Port Based VLAN Setting VLAN ID: Select the ID number of VLAN from the drop-down list. Port List: Displays the port members in the VLAN. Figure 6-4 Port Based VLAN Configuration To ensure the normal communication of the factory switch, the default VLAN of all ports is set to select the port of VLAN. VLAN 1 cannot be deleted. Ports: Click the port icon to VLAN1. Delete VLAN: Click Delete to delete the corresponding VLAN. 30 Easy Smart Configuration Utility User Guide...
... Config Port Based VLAN Configuration: Enable or disable Port Based VLAN mode. ¾ Port Based VLAN Setting VLAN ID: Select the ID number of VLAN from the drop-down list. Port List: Displays the port members in the VLAN. Figure 6-4 Port Based VLAN Configuration To ensure the normal communication of the factory switch, the default VLAN of all ports is set to select the port of VLAN. VLAN 1 cannot be deleted. Ports: Click the port icon to VLAN1. Delete VLAN: Click Delete to delete the corresponding VLAN. 30 Easy Smart Configuration Utility User Guide...
TL-SG105E V1 UG
Page 34
....1Q VLAN feature and view the related settings. It ranges from 2 to 4094. 31 Easy Smart Configuration Utility User Guide Note: A VLAN cannot be the subset or superset of other VLANs. 6.3 802.1Q VLAN On this screen: ¾ Global Config 802.1Q VLAN Status: Enable or disable 802.1Q VLAN mode. ¾ 802.1Q VLAN Setting VLAN ID: Enter the ID number of all ports is set to be modified or deleted.
....1Q VLAN feature and view the related settings. It ranges from 2 to 4094. 31 Easy Smart Configuration Utility User Guide Note: A VLAN cannot be the subset or superset of other VLANs. 6.3 802.1Q VLAN On this screen: ¾ Global Config 802.1Q VLAN Status: Enable or disable 802.1Q VLAN mode. ¾ 802.1Q VLAN Setting VLAN ID: Enter the ID number of all ports is set to be modified or deleted.
TL-SG105E V1 QIG
Page 1
.... Next enter the username and password (both admin) for example throughout this Guide. For more information, please visit our website: http://www.tp-link.com Power Adapter TL-SG108E Ethernet Ports (1-8) Internet PC Note: For simplicity, we will appear. Installation Guide 58-Port Gigabit Easy Smart Switch TL-SG105E/TL-SG108E Connection 7106504846 REV2.0.0 For more details about how to install the utility and configure the switch, please refer to install the program. 2. Install the configuration utility 1. The switch configuration utility is plug...
.... Next enter the username and password (both admin) for example throughout this Guide. For more information, please visit our website: http://www.tp-link.com Power Adapter TL-SG108E Ethernet Ports (1-8) Internet PC Note: For simplicity, we will appear. Installation Guide 58-Port Gigabit Easy Smart Switch TL-SG105E/TL-SG108E Connection 7106504846 REV2.0.0 For more details about how to install the utility and configure the switch, please refer to install the program. 2. Install the configuration utility 1. The switch configuration utility is plug...
TL-SG105E V1 QIG
Page 2
...;F) 10%~90% non-condensing 5%~90% non-condensing General Specifications Standard Protocol Data Transfer Rate Network Media (Cable) Interface LED indicators Transfer Method MAC Address Learning Frame Filter Rate Frame Forward Rate IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3x, IEEE802.1p, IEEE802.1q CSMA/CD Ethernet: 10Mbps (Half Duplex) 20Mbps (Full Duplex) Fast Ethernet: 100Mbps (Half Duplex) 200Mbps (Full Duplex) Gigabit Ethernet: 2000Mbps (Full Duplex) 10Base-T: UTP category 3, 4, 5 cable (maximum 100m) EIA/TIA-568 100Ω...
...;F) 10%~90% non-condensing 5%~90% non-condensing General Specifications Standard Protocol Data Transfer Rate Network Media (Cable) Interface LED indicators Transfer Method MAC Address Learning Frame Filter Rate Frame Forward Rate IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3x, IEEE802.1p, IEEE802.1q CSMA/CD Ethernet: 10Mbps (Half Duplex) 20Mbps (Full Duplex) Fast Ethernet: 100Mbps (Half Duplex) 200Mbps (Full Duplex) Gigabit Ethernet: 2000Mbps (Full Duplex) 10Base-T: UTP category 3, 4, 5 cable (maximum 100m) EIA/TIA-568 100Ω...