Page 6
... SMPTE 305M input/output (HDCAM video/ audio data) (option) • Time code input/output • CUE audio output High quality four-channel audio High quality 20 bit/48 kHz AES/EBU digital audio is equipped with Betacam SX playback heads and analog Betacam DT heads, for transferring HDCAM data, audio data...
... SMPTE 305M input/output (HDCAM video/ audio data) (option) • Time code input/output • CUE audio output High quality four-channel audio High quality 20 bit/48 kHz AES/EBU digital audio is equipped with Betacam SX playback heads and analog Betacam DT heads, for transferring HDCAM data, audio data...
Operation Manual
Page 12
...segments light. In this lights when the level of the display corresponding to the right monitor channel. DATA DATA indicator dB OVER dB 0 20 2 -10 110 -20 0 -1 -30 -10 -40 -20 -2 -60 -40 L EMPH R OVER indicator Level meter Monitor channel L and R indicators EMPH indicator DATA indicator: Lights when the ... flashes, and if the audio level goes below the minimum display level, the bottom segment flashes. You can also use the setup menu to +20 dB as data signals. EMPH (emphasis) indicator: While the unit is the reference level). FULL: The display covers the range -60 dB to...
...segments light. In this lights when the level of the display corresponding to the right monitor channel. DATA DATA indicator dB OVER dB 0 20 2 -10 110 -20 0 -1 -30 -10 -40 -20 -2 -60 -40 L EMPH R OVER indicator Level meter Monitor channel L and R indicators EMPH indicator DATA indicator: Lights when the ... flashes, and if the audio level goes below the minimum display level, the bottom segment flashes. You can also use the setup menu to +20 dB as data signals. EMPH (emphasis) indicator: While the unit is the reference level). FULL: The display covers the range -60 dB to...
Operation Manual
Page 86
... the drum rotates in two places. Note You can insert the VITC signal in "Standby OFF mode". OFF : Drum does not rotate. T.REL: Switch to 20. Select the tape tension state in two places. LOOSE: Reduce the tape tension further from the NORML setting. (Select "LOOSE" when the unit is maintained...
... the drum rotates in two places. Note You can insert the VITC signal in "Standby OFF mode". OFF : Drum does not rotate. T.REL: Switch to 20. Select the tape tension state in two places. LOOSE: Reduce the tape tension further from the NORML setting. (Select "LOOSE" when the unit is maintained...
Operation Manual
Page 87
... 59.94i, 29.97PsF mode Select a line to insert the VITC in. (For SD output) 12H to 18H to 20H: Select any line from 9 to 20. TCG/R : Output the playback time code signal during playback (In 50i or 25PsF mode of time code signals (LTC). OUTPT: Use the same phase as...
... 59.94i, 29.97PsF mode Select a line to insert the VITC in. (For SD output) 12H to 18H to 20H: Select any line from 9 to 20. TCG/R : Output the playback time code signal during playback (In 50i or 25PsF mode of time code signals (LTC). OUTPT: Use the same phase as...
Operation Manual
Page 89
... not to force the "Y-add" function off blanking. THROU: Switch off blanking. 9 ... THROU: Switch off blanking. 20 LINE 20 Specify blanking for lines 9 to 22. 22 BLANK : Carry out blanking. LINE 22 Specify blanking for line 20. THROU: Switch off blanking. 23 LINE 23 Specify blanking for lines 12 to 19. THROU: Regardless...
... not to force the "Y-add" function off blanking. THROU: Switch off blanking. 9 ... THROU: Switch off blanking. 20 LINE 20 Specify blanking for lines 9 to 22. 22 BLANK : Carry out blanking. LINE 22 Specify blanking for line 20. THROU: Switch off blanking. 23 LINE 23 Specify blanking for lines 12 to 19. THROU: Regardless...
Operation Manual
Page 90
... setting. 0.0% to 7.5% to 10.0%: Set the setup amount to be removed from the Betacam playback signal in this range, in 0.5% increments. (Continued) Chapter 9 Setup Menus 9-20 Chapter 9 Setup Menus MSTER : Set the output signal to the master setting. 0.0% to 7.5% to 10.0%: Set the setup amount to be added to a composite output...
... setting. 0.0% to 7.5% to 10.0%: Set the setup amount to be removed from the Betacam playback signal in this range, in 0.5% increments. (Continued) Chapter 9 Setup Menus 9-20 Chapter 9 Setup Menus MSTER : Set the output signal to the master setting. 0.0% to 7.5% to 10.0%: Set the setup amount to be added to a composite output...
Operation Manual
Page 93
... output timing is advanced, and when it is higher than 80H, the output timing is delayed. (at 80H, 128 samples = approx. 2.7 ms, and 1 sample=approx. 20 µs) 0 to 80 to speed correction is output. OFF: Digital jog sound is OFF regardless of the setting of this range 808 INTERNAL AUDIO Select... has not been confirmed: Current state is non-audio) AUTO: As follows, depending on . SIGNAL GENERATOR OFF : No operation SILNC: Silent signal 1KHZ: At 1 kHz, -20 dB FS sine wave is muted.
... output timing is advanced, and when it is higher than 80H, the output timing is delayed. (at 80H, 128 samples = approx. 2.7 ms, and 1 sample=approx. 20 µs) 0 to 80 to speed correction is output. OFF: Digital jog sound is OFF regardless of the setting of this range 808 INTERNAL AUDIO Select... has not been confirmed: Current state is non-audio) AUTO: As follows, depending on . SIGNAL GENERATOR OFF : No operation SILNC: Silent signal 1KHZ: At 1 kHz, -20 dB FS sine wave is muted.
Operation Manual
Page 101
... 08 DRUM TROUBLE 09 TH/UNTH MOTOR 0A THREADING 10 HUMID 11 TAPE T/E SENSOR 12 TAPE TOP SENSOR 13 TAPE END SENSOR 14 FAN MOTOR 20 CASS COMP MOTOR 21 REEL SFT MOTOR 22 REEL POS SENSOR 23 THRED RING SENS 92 INTERNAL I/F1 93 CPU INITIALIZE ERROR 95 OTHERS NV...
... 08 DRUM TROUBLE 09 TH/UNTH MOTOR 0A THREADING 10 HUMID 11 TAPE T/E SENSOR 12 TAPE TOP SENSOR 13 TAPE END SENSOR 14 FAN MOTOR 20 CASS COMP MOTOR 21 REEL SFT MOTOR 22 REEL POS SENSOR 23 THRED RING SENS 92 INTERNAL I/F1 93 CPU INITIALIZE ERROR 95 OTHERS NV...
Operation Manual
Page 105
... V), 14 A (100 V) (2) Gemessen in EN55103-1: 18 A (230 V) Operating temperature 5°C to 40°C (41°F to 104°F) Storage temperature -20°C to +60°C (-4°F to +140°F) Humidity 20 to 90% Mass 23 kg (50 lb 11 oz) Dimensions (w/h/d) 427 × 194 × 544 mm (16 7/8 × 7 3/4 × 21 1/2 inches...
... V), 14 A (100 V) (2) Gemessen in EN55103-1: 18 A (230 V) Operating temperature 5°C to 40°C (41°F to 104°F) Storage temperature -20°C to +60°C (-4°F to +140°F) Humidity 20 to 90% Mass 23 kg (50 lb 11 oz) Dimensions (w/h/d) 427 × 194 × 544 mm (16 7/8 × 7 3/4 × 21 1/2 inches...
Operation Manual
Page 106
... 0 to 5.75 MHz +0.5 dB/ −2.0 dB S/N ratio 53 dB or more Differential gain 2% or less Differential phase 2° or less Y/C delay 20 ns or less K factor (2T pulse) 1% or less Output SCH phase Based upon RS-170A/CCIR R.624- 3 (Adjustable by using the menu) Digital audio..., selectable) Emphasis T1= 50 µs, T2=15 µs (on/off selectable in recording mode) Analog output (CH1 to CH4) A/D, D/A quantization 20 bits/sample Frequency response 20 Hz to 20 kHz +0.5 dB/ -1.0 dB (0 dB at 1 kHz) Dynamic range 95 dB or more (at 1 kHz, emphasis on) Distortion 0.05% or less...
... 0 to 5.75 MHz +0.5 dB/ −2.0 dB S/N ratio 53 dB or more Differential gain 2% or less Differential phase 2° or less Y/C delay 20 ns or less K factor (2T pulse) 1% or less Output SCH phase Based upon RS-170A/CCIR R.624- 3 (Adjustable by using the menu) Digital audio..., selectable) Emphasis T1= 50 µs, T2=15 µs (on/off selectable in recording mode) Analog output (CH1 to CH4) A/D, D/A quantization 20 bits/sample Frequency response 20 Hz to 20 kHz +0.5 dB/ -1.0 dB (0 dB at 1 kHz) Dynamic range 95 dB or more (at 1 kHz, emphasis on) Distortion 0.05% or less...
Operation Manual
Page 108
... 4.5 MHz +0.5 dB/ -4.0 dB 30 Hz to 1.5 MHz +0.5 dB/-3.0dB 51 dB or more 48 dB or more 2% or less 3% or less 4% or less 20 ns or less Audio Metal tape LNG Frequency response (at 10 dB below reference level a)) 50 Hz to 15 kHz +1.5 dB/ -3.0 dB S/N ratio (at 3% distortion... level) 72 dB or more Distortion (THD at 1 kHz reference 1% or less level a)) Wow and flutter 0.1% rms or less AFM Frequency response (at reference 20 Hz to 20 kHz +0.5 dB/-2.0 dB level a)) S/N ratio (at 3% distortion level) 85 dB or more Distortion (THD at 1 kHz reference 0.5% or less level a)) a) Reference level: +4...
... 4.5 MHz +0.5 dB/ -4.0 dB 30 Hz to 1.5 MHz +0.5 dB/-3.0dB 51 dB or more 48 dB or more 2% or less 3% or less 4% or less 20 ns or less Audio Metal tape LNG Frequency response (at 10 dB below reference level a)) 50 Hz to 15 kHz +1.5 dB/ -3.0 dB S/N ratio (at 3% distortion... level) 72 dB or more Distortion (THD at 1 kHz reference 1% or less level a)) Wow and flutter 0.1% rms or less AFM Frequency response (at reference 20 Hz to 20 kHz +0.5 dB/-2.0 dB level a)) S/N ratio (at 3% distortion level) 85 dB or more Distortion (THD at 1 kHz reference 0.5% or less level a)) a) Reference level: +4...
Operation Manual
Page 113
... 2-2 V VAR button 2-8 Variable speed mode 4-4 VIDEO (function menu) 8-4 VIDEO CONTROL(15P) connector 2-15 VIDEO CONTROL(9P) connector 2-15 Video test signal (setup menu item 710) 9-20 VITC field 3-5 indicator 2-6 V.PROC (function menu) 8-4 Y YC DLY (function menu) 8-4 I-2 Index