Technical Manual
Page 3
...features 380,000 effective picture elements for the EVI-D100 and 440,000 for the EVI-D100P, which enables high-resolution shooting. • In addition to high-speed pan/tilt action, improvement of the noise reduction mechanism lets you use the Color Video Camera for a variety of purposes. • ...VISCA lets you operate your Color Video Camera from a computer. ...
...features 380,000 effective picture elements for the EVI-D100 and 440,000 for the EVI-D100P, which enables high-resolution shooting. • In addition to high-speed pan/tilt action, improvement of the noise reduction mechanism lets you use the Color Video Camera for a variety of purposes. • ...VISCA lets you operate your Color Video Camera from a computer. ...
Technical Manual
Page 4
To obtain a cable, consult the dealer where you can operate the camera with the computer. Connection Connection Video cable (not supplied) to Video input to VIDEO S-Video cable (1-751-416-11 to S VIDEO not supplied) to S-Video ... cable (not supplied) 1) to RS-232C to VISCA IN to VISCA OUT Computer, TV or VCR with a video input jack To VISCA IN of other EVI-D100/Ps (when connecting to more than one camera) AC power adaptor MPA-AC1 (supplied) to AC outlet to DC IN 12V Power cord (supplied) 1) When the...
To obtain a cable, consult the dealer where you can operate the camera with the computer. Connection Connection Video cable (not supplied) to Video input to VIDEO S-Video cable (1-751-416-11 to S VIDEO not supplied) to S-Video ... cable (not supplied) 1) to RS-232C to VISCA IN to VISCA OUT Computer, TV or VCR with a video input jack To VISCA IN of other EVI-D100/Ps (when connecting to more than one camera) AC power adaptor MPA-AC1 (supplied) to AC outlet to DC IN 12V Power cord (supplied) 1) When the...
Technical Manual
Page 8
... Iris and Gain, Fixed Shutter (EVI-D100: 1/60 sec., EVI-D100P: 1/50 sec.) • Shutter Priority 1) Variable Shutter Speed, Auto Iris and Gain (1/4 (EVI-D100) or 1/3 (EVI-D100P) to an AC outlet. The data is erased when the camera is set automatically, according to the camera. Altogether 9 modes are set to... ON and the camera has been connected to 1/10,000 sec., 20 steps,...
... Iris and Gain, Fixed Shutter (EVI-D100: 1/60 sec., EVI-D100P: 1/50 sec.) • Shutter Priority 1) Variable Shutter Speed, Auto Iris and Gain (1/4 (EVI-D100) or 1/3 (EVI-D100P) to an AC outlet. The data is erased when the camera is set automatically, according to the camera. Altogether 9 modes are set to... ON and the camera has been connected to 1/10,000 sec., 20 steps,...
Technical Manual
Page 11
An × indicates that the setting is memorized in the camera. Full Auto Manual - - - - Basic Functions Category Mode/Position Pan/Tilt Zoom Focus WB AE Aperture Effect OSD IR AutoPowerOff Memory VISCA Pan/Tilt Position Pan/... is backed up. Initial values Home position movable-range maximum Wide end On Auto High - Initial Values and Backup Initial values of functions of the EVI-D100/P are backed up regardless of the BACKUP switch setting when you turn the power off using a VISCA command or the Remote Commander (standby mode). 2) When...
An × indicates that the setting is memorized in the camera. Full Auto Manual - - - - Basic Functions Category Mode/Position Pan/Tilt Zoom Focus WB AE Aperture Effect OSD IR AutoPowerOff Memory VISCA Pan/Tilt Position Pan/... is backed up. Initial values Home position movable-range maximum Wide end On Auto High - Initial Values and Backup Initial values of functions of the EVI-D100/P are backed up regardless of the BACKUP switch setting when you turn the power off using a VISCA command or the Remote Commander (standby mode). 2) When...
Technical Manual
Page 19
...) = category code 1) QQ = 01 (Command), 09 (Inquiry) 2) RR = 00 (Interface), 04 (camera 1), 06 (Pan/Tilter) X = 1 to the EVI-D100/P. The packet Command List sent to all devices at X. G Inquiry Used for setting EVI-D100/P units can be hexadecimal 88H. The packet from the EVI-D100/P assigned address 2 is 82H. For example, the header of broadcast, the header...
...) = category code 1) QQ = 01 (Command), 09 (Inquiry) 2) RR = 00 (Interface), 04 (camera 1), 06 (Pan/Tilter) X = 1 to the EVI-D100/P. The packet Command List sent to all devices at X. G Inquiry Used for setting EVI-D100/P units can be hexadecimal 88H. The packet from the EVI-D100/P assigned address 2 is 82H. For example, the header of broadcast, the header...
Technical Manual
Page 25
EVI-D100/P Commands EVI-D100/P Command List (1/4) Command Set AddressSet IF_Clear CommandCancel CAM_Power CAM_AutoPowerOff Command Broadcast Broadcast On Off (Standby) Direct Command Packet 88 30 01 FF 88 01 00 ... mode One push WB trigger Manual control of R Gain pqrs: R Gain 0000 to FFFF (65535min) Initial value: 0000 The power automatically turns off if the camera does not receive any VISCA commands or any signals from the Remote Commander for the duration you set in the timer.
EVI-D100/P Commands EVI-D100/P Command List (1/4) Command Set AddressSet IF_Clear CommandCancel CAM_Power CAM_AutoPowerOff Command Broadcast Broadcast On Off (Standby) Direct Command Packet 88 30 01 FF 88 01 00 ... mode One push WB trigger Manual control of R Gain pqrs: R Gain 0000 to FFFF (65535min) Initial value: 0000 The power automatically turns off if the camera does not receive any VISCA commands or any signals from the Remote Commander for the duration you set in the timer.
Technical Manual
Page 40
... an AC outlet or by using VISCA commands for the EVI-D30/D31 in the camera is caused by switching the D30/D31 mode switch at the bottom of the VISCA commands for the EVI-D100/P correspond to one for the EVI-D100/P and executes the command. However, some of parameters. To change . The... change the D30/D31 mode setting, move the D30/D31 mode switch to ON or OFF while the camera's power is off , the data backed up in definitions of the VISCA commands for the EVI-D100/P are subject to translation. • Zoom speed • Zoom position • Focus position • Shutter ...
... an AC outlet or by using VISCA commands for the EVI-D30/D31 in the camera is caused by switching the D30/D31 mode switch at the bottom of the VISCA commands for the EVI-D100/P correspond to one for the EVI-D100/P and executes the command. However, some of parameters. To change . The... change the D30/D31 mode setting, move the D30/D31 mode switch to ON or OFF while the camera's power is off , the data backed up in definitions of the VISCA commands for the EVI-D100/P are subject to translation. • Zoom speed • Zoom position • Focus position • Shutter ...
Technical Manual
Page 42
...) to 8400h (NEAR, 10 cm) Translation of commands Accepted parameters Translation Values less than 8400h Accepts as is Zoom position Cameras EVI-D30/D31 EVI-D100/P Parameters 0000h (WIDE) to 03FFh (TELE) 0000h (WIDE) to 7000h (TELE, digital 4×) Translation of commands Accepted...define the focus position, it sends back the current D30/D31 parameters. CDo3m0m/3a1nMd oLdiset Translating Parameters Zoom speed Cameras EVI-D30/D31 EVI-D100/P Parameters 02h (Min. speed) Translation of commands Accepted parameters Translation 00h, 01h Translates to 02h Values greater...
...) to 8400h (NEAR, 10 cm) Translation of commands Accepted parameters Translation Values less than 8400h Accepts as is Zoom position Cameras EVI-D30/D31 EVI-D100/P Parameters 0000h (WIDE) to 03FFh (TELE) 0000h (WIDE) to 7000h (TELE, digital 4×) Translation of commands Accepted...define the focus position, it sends back the current D30/D31 parameters. CDo3m0m/3a1nMd oLdiset Translating Parameters Zoom speed Cameras EVI-D30/D31 EVI-D100/P Parameters 02h (Min. speed) Translation of commands Accepted parameters Translation 00h, 01h Translates to 02h Values greater...
Technical Manual
Page 43
...b (1/500) b (1/600) b (1/725) b (1/850) b (1/1000) b (1/1250) b (1/1500) b (1/1750) b (1/2000) b (1/2500) b (1/3000) b (1/3500) b (1/4000) b (1/6000) b (1/10000) b EVI-D100P Parameters Shutter speed 0004h (1/50) 0004h (1/50) 0005h (1/75) 0006h (1/100) 0006h (1/100) 0007h (1/120) 0008h (1/150) 0008h (1/150) 0009h (1/215) 0009h (1/215) 000Ah (1/300...(1/6000) 0013h (1/10000) Translation when answering inquiry commands The EVI-D100/P translates its parameters to the instant the camera accepts another CAM_Shutter or CAM_AE command, it sends back the ...
...b (1/500) b (1/600) b (1/725) b (1/850) b (1/1000) b (1/1250) b (1/1500) b (1/1750) b (1/2000) b (1/2500) b (1/3000) b (1/3500) b (1/4000) b (1/6000) b (1/10000) b EVI-D100P Parameters Shutter speed 0004h (1/50) 0004h (1/50) 0005h (1/75) 0006h (1/100) 0006h (1/100) 0007h (1/120) 0008h (1/150) 0008h (1/150) 0009h (1/215) 0009h (1/215) 000Ah (1/300...(1/6000) 0013h (1/10000) Translation when answering inquiry commands The EVI-D100/P translates its parameters to the instant the camera accepts another CAM_Shutter or CAM_AE command, it sends back the ...
Technical Manual
Page 44
... 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 10h 11h 12h 13h 14h 15h 16h 17h 18h D100/P 2.0 2.4 3.0 3.7 4.7 6.1 7.4 9.1 11 14 18 22 27 34 42 52 65 81 ...oLdiset Tilt Parameters 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 10h 11h 12h 13h 14h D100/P 2.0 2.4 3.0 3.7 4.7 6.1 7.4 9.1 11 14 18 22 27 34 42 52 65 81 100 125 Speed (deg/....5 b 30.0 b 32.5 b 35.0 b 37.5 b 40.0 b 42.5 b 45.0 b 47.5 b 50.0 44 When the camera accepts commands such as PantiltDrive Home, Reset, or CAM_Memory Recall, the operation speed is OFF. Pan/tilt speed The actual speed that is defined by...
... 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 10h 11h 12h 13h 14h 15h 16h 17h 18h D100/P 2.0 2.4 3.0 3.7 4.7 6.1 7.4 9.1 11 14 18 22 27 34 42 52 65 81 ...oLdiset Tilt Parameters 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 10h 11h 12h 13h 14h D100/P 2.0 2.4 3.0 3.7 4.7 6.1 7.4 9.1 11 14 18 22 27 34 42 52 65 81 100 125 Speed (deg/....5 b 30.0 b 32.5 b 35.0 b 37.5 b 40.0 b 42.5 b 45.0 b 47.5 b 50.0 44 When the camera accepts commands such as PantiltDrive Home, Reset, or CAM_Memory Recall, the operation speed is OFF. Pan/tilt speed The actual speed that is defined by...
Technical Manual
Page 45
... command 88 times, one step after another to turn the camera to the right side: Cameras EVI-D30/D31 EVI-D100/P whose D30/D31 mode is accumulated from translation. Pan/tilt position Pan position Cameras EVI-D30/D31 EVI-D100/P Parameters FC90h (-100 degrees) to 0370h (+100 degrees) FA60h... (-100 degrees) to 05A0h (+100 degrees) Tilt position Cameras EVI-D30/D31 EVI-D100/P Parameters FED4h (-25 degrees) to 012Ch (+25 degrees) ...
... command 88 times, one step after another to turn the camera to the right side: Cameras EVI-D30/D31 EVI-D100/P whose D30/D31 mode is accumulated from translation. Pan/tilt position Pan position Cameras EVI-D30/D31 EVI-D100/P Parameters FC90h (-100 degrees) to 0370h (+100 degrees) FA60h... (-100 degrees) to 05A0h (+100 degrees) Tilt position Cameras EVI-D30/D31 EVI-D100/P Parameters FED4h (-25 degrees) to 012Ch (+25 degrees) ...
Technical Manual
Page 46
... TELE end : 600 mm Minimum illumination 3.5 lx (F1.8)/with 50 IRE Illumination range 3.5 to 100,000 lx Shutter speed EVI-D100: 1/4 to 1/10,000 s (VISCA control) EVI-D100P: 1/3 to 1/10,000 s (VISCA control) Horizontal resolution NTSC : 470 TV (WIDE end) PAL : 460 TV (WIDE...0 °C to 40 °C (32 °F to 104 °F) Storage temperature - 20 °C to 60 °C (- 4 °F to 140 °F) Dimensions Video camera: 113 × 120 × 132 mm (4 1/2 × 4 3/4 × 5 1/4 in.) (w/h/d) Remote Commander: 56 × 26 × 210 mm (2 1/4 × 1 1/16 ...
... TELE end : 600 mm Minimum illumination 3.5 lx (F1.8)/with 50 IRE Illumination range 3.5 to 100,000 lx Shutter speed EVI-D100: 1/4 to 1/10,000 s (VISCA control) EVI-D100P: 1/3 to 1/10,000 s (VISCA control) Horizontal resolution NTSC : 470 TV (WIDE end) PAL : 460 TV (WIDE...0 °C to 40 °C (32 °F to 104 °F) Storage temperature - 20 °C to 60 °C (- 4 °F to 140 °F) Dimensions Video camera: 113 × 120 × 132 mm (4 1/2 × 4 3/4 × 5 1/4 in.) (w/h/d) Remote Commander: 56 × 26 × 210 mm (2 1/4 × 1 1/16 ...