RS232C Basic
Page 1
BASIC SERIAL COMMAND SPECIFICATIONS PLC-WL2500 PLC-WL2501 PLC-WL2503 Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division
BASIC SERIAL COMMAND SPECIFICATIONS PLC-WL2500 PLC-WL2501 PLC-WL2503 Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division
RS232C Basic
Page 2
PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications CONTENTS 1. Connection ...4 3. Status Read Command Table 8 6. Computer 1 Command 11 6.10. Computer 2 Command 12 6.11. Video Command...12 6.12. Command 12 6.14. ...
PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications CONTENTS 1. Connection ...4 3. Status Read Command Table 8 6. Computer 1 Command 11 6.10. Computer 2 Command 12 6.11. Video Command...12 6.12. Command 12 6.14. ...
RS232C Basic
Page 3
.... Operation Requirements 21 7.4. POINTER LEFT Command 17 6.46. Status Read Command 22 7.5. Direct on Cancel Command 16 6.37. Command 17 6.42. ENTER Command 18 6.49. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.32. BRIGHTNESS + Command 15 6.33.
.... Operation Requirements 21 7.4. POINTER LEFT Command 17 6.46. Status Read Command 22 7.5. Direct on Cancel Command 16 6.37. Command 17 6.42. ENTER Command 18 6.49. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.32. BRIGHTNESS + Command 15 6.33.
RS232C Basic
Page 4
... Data Length 8 bit Parity N/A Stop Bit 1 Flow Control N/A 1) Transmission speed: initial setting value is 19200. 2) Transmission speed can be used to a computer and a projector. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 1. These specifications define projector control commands for connection to remotely control a projector through RS-232C from a computer. 2. The projector control commands...
... Data Length 8 bit Parity N/A Stop Bit 1 Flow Control N/A 1) Transmission speed: initial setting value is 19200. 2) Transmission speed can be used to a computer and a projector. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 1. These specifications define projector control commands for connection to remotely control a projector through RS-232C from a computer. 2. The projector control commands...
RS232C Basic
Page 5
... is defined as one command/one second to Status Read Commands depends on commands. Do not issue any command. 6. Notes for commands must be Capital (A - PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 3.
... is defined as one command/one second to Status Read Commands depends on commands. Do not issue any command. 6. Notes for commands must be Capital (A - PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 3.
RS232C Basic
Page 6
...; D.ZOOM + D.ZOOM S-video Image Colorboard POINTER RIGHT POINTER LEFT POINTER UP POINTER DOWN ――― ENTER ――― means no function. 6/25 PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 4. C0B AUDIO MUTE ON C0C AUDIO MUTE OFF C0D VIDEO MUTE ON C0E VIDEO MUTE OFF C0F Screen Normal size (4 3) C10...
...; D.ZOOM + D.ZOOM S-video Image Colorboard POINTER RIGHT POINTER LEFT POINTER UP POINTER DOWN ――― ENTER ――― means no function. 6/25 PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 4. C0B AUDIO MUTE ON C0C AUDIO MUTE OFF C0D VIDEO MUTE ON C0E VIDEO MUTE OFF C0F Screen Normal size (4 3) C10...
RS232C Basic
Page 7
PRESENTATION TIMER PRESENTATION TIMER(EXIT KEYSTONE ↑ KEYSTONE 7/25 PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 C53 C54 C55 C56 C57 C58 C59 C5A Item FREEZE ON FREEZE OFF Computer 1 Analog RGB Computer 1 RGB (Scart Computer 1 Component ――― means no function. Command C80 C81 C82 C83 C84 C85 C86 C87 C88 C89 C8A C8B C8C C8D C8E C8F C90 C91 C92 C93 C94 C95 C96 C97 C98 C99 C9A Item Auto PC ADJ.
PRESENTATION TIMER PRESENTATION TIMER(EXIT KEYSTONE ↑ KEYSTONE 7/25 PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 C53 C54 C55 C56 C57 C58 C59 C5A Item FREEZE ON FREEZE OFF Computer 1 Analog RGB Computer 1 RGB (Scart Computer 1 Component ――― means no function. Command C80 C81 C82 C83 C84 C85 C86 C87 C88 C89 C8A C8B C8C C8D C8E C8F C90 C91 C92 C93 C94 C95 C96 C97 C98 C99 C9A Item Auto PC ADJ.
RS232C Basic
Page 8
PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 5. Memo 8/25 Status Read Command Table Command Item CR0 CR1 CR2 Status Read Input Mode Read ――― CR3 (Corresponding) Lamp Time Read CR4 CR5 Setting Read ――― CR6 Temp Read CR7 Lamp Mode Read ――― means no function.
PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 5. Memo 8/25 Status Read Command Table Command Item CR0 CR1 CR2 Status Read Input Mode Read ――― CR3 (Corresponding) Lamp Time Read CR4 CR5 Setting Read ――― CR6 Temp Read CR7 Lamp Mode Read ――― means no function.
RS232C Basic
Page 9
... Example Switch the projector to receive next command. [ACK][CR] (0x06 0x0D)When received Functional Execution Commands. 6.1.2 "?" [CR] When the received data cannot be decoded. 6.2. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.
... Example Switch the projector to receive next command. [ACK][CR] (0x06 0x0D)When received Functional Execution Commands. 6.1.2 "?" [CR] When the received data cannot be decoded. 6.2. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.
RS232C Basic
Page 10
... process Cooling Down in process Cooling Down due to Abnormal Temperature Abnormal Temperature Status Abnormal Power Status Power Save / Cooling Down in standby. 10/25 PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.4.
... process Cooling Down in process Cooling Down due to Abnormal Temperature Abnormal Temperature Status Abnormal Power Status Power Save / Cooling Down in standby. 10/25 PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.4.
RS232C Basic
Page 11
... "C00" [CR] Detail Power ON When already Power is ON, nothing is set to On1/On2. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 11/25 PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.5. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.8. However, as soon as ON/STAND-BY button of the projector and the remote control...
... "C00" [CR] Detail Power ON When already Power is ON, nothing is set to On1/On2. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 11/25 PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.5. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.8. However, as soon as ON/STAND-BY button of the projector and the remote control...
RS232C Basic
Page 12
... Volume Down This command operates the same way as "MUTE" button of the remote control for Mute ON, but does not work for Mute OFF. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.10. VOLUME + Command Command "C09" [CR] Detail Volume Up. VOLUME - This command works the same as "VOLUME-" button of the...
... Volume Down This command operates the same way as "MUTE" button of the remote control for Mute ON, but does not work for Mute OFF. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.10. VOLUME + Command Command "C09" [CR] Detail Volume Up. VOLUME - This command works the same as "VOLUME-" button of the...
RS232C Basic
Page 13
..." button of remote control for No Show OFF, but does not work for No Show OFF. This command is valid though D.Zoom is in operation. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.15. This command works the same as "MUTE" button of the remote control for No Show ON, but does not...
..." button of remote control for No Show OFF, but does not work for No Show OFF. This command is valid though D.Zoom is in operation. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.15. This command works the same as "MUTE" button of the remote control for No Show ON, but does not...
RS232C Basic
Page 15
Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.30. Hide On-Screen Display unconditionally. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.28. DISPLAY CLEAR Command Command "C1E" [CR] Detail Hide On-Screen Display. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.33. MENU OFF ...
Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.30. Hide On-Screen Display unconditionally. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.28. DISPLAY CLEAR Command Command "C1E" [CR] Detail Hide On-Screen Display. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.33. MENU OFF ...
RS232C Basic
Page 16
.../OFF. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 16/25 Power Management Shut down Command Command "C2E" [CR] Detail Set Power Management to Shut down mode. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.34. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.38. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.37. Direct on Setting Command Command...
.../OFF. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 16/25 Power Management Shut down Command Command "C2E" [CR] Detail Set Power Management to Shut down mode. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.34. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.38. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.37. Direct on Setting Command Command...
RS232C Basic
Page 17
...] Unacceptable " "[CR] 6.42. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.43. D.ZOOM + Command Command "C30" [CR] Detail Enter Digital Zoom mode and expand image size. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.40. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.41. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.44. POINTER LEFT Command Command "C3B" [CR...
...] Unacceptable " "[CR] 6.42. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.43. D.ZOOM + Command Command "C30" [CR] Detail Enter Digital Zoom mode and expand image size. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.40. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.41. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.44. POINTER LEFT Command Command "C3B" [CR...
RS232C Basic
Page 18
...] Unacceptable " "[CR] 6.47. ENTER Command Command "C3F" [CR] Detail This command works the same as the pointer "▲" of the projector and the remote control. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.46. FREEZE OFF Command Command "C44" [CR] Detail Cancel Freeze mode. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.49. This command...
...] Unacceptable " "[CR] 6.47. ENTER Command Command "C3F" [CR] Detail This command works the same as the pointer "▲" of the projector and the remote control. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.46. FREEZE OFF Command Command "C44" [CR] Detail Cancel Freeze mode. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.49. This command...
RS232C Basic
Page 19
PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.52. This command works the same as holding on the "P-TIMER" button of the remote control. KEYSTONE ↑Command Command "C8E" [...
PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.52. This command works the same as holding on the "P-TIMER" button of the remote control. KEYSTONE ↑Command Command "C8E" [...
RS232C Basic
Page 20
Acceptable Response [ACK] [CR] Unacceptable " "[CR] 20/25 KEYSTONE ↓Command Command "C8F" [CR] Detail Correct keystone distortion by reducing down part of image. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.58.
Acceptable Response [ACK] [CR] Unacceptable " "[CR] 20/25 KEYSTONE ↓Command Command "C8F" [CR] Detail Correct keystone distortion by reducing down part of image. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.58.
RS232C Basic
Page 21
... data. "CR" Command [CR] Command 1 character(See Basic Status Read Command Table) 7.1.2. When a projector receives the appropriate command, it returns a character line as below; Format 7.1.1. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 7.
... data. "CR" Command [CR] Command 1 character(See Basic Status Read Command Table) 7.1.2. When a projector receives the appropriate command, it returns a character line as below; Format 7.1.1. PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 7.