Owner's Manual
Page 1
Owner's Manual Multimedia Projector MODEL PLC-ET30L *Projection lens is optional.
Owner's Manual Multimedia Projector MODEL PLC-ET30L *Projection lens is optional.
Owner's Manual
Page 9
... supplied is a safety feature to radio communications. The wire which is coloured blue must be connected to defeat this projector meets the requirement for use the plug with the cover omitted. Compliance Federal Communications Commission Notice This equipment has been ...help. If such changes or modifications should be made, you could be unable to stop operation of the plug (i.e. Model Number(s) : PLC-ET30L Trade Name : Sanyo Responsible party : SANYO FISHER COMPANY Address : 21605 Plummer Street, Chatsworth, California 91311 U.S.A. Telephone No. : (818)998-7322 AC Power...
... supplied is a safety feature to radio communications. The wire which is coloured blue must be connected to defeat this projector meets the requirement for use the plug with the cover omitted. Compliance Federal Communications Commission Notice This equipment has been ...help. If such changes or modifications should be made, you could be unable to stop operation of the plug (i.e. Model Number(s) : PLC-ET30L Trade Name : Sanyo Responsible party : SANYO FISHER COMPANY Address : 21605 Plummer Street, Chatsworth, California 91311 U.S.A. Telephone No. : (818)998-7322 AC Power...
Owner's Manual
Page 59
... lamp with the screw. 5 Connect the AC power cord to the dealer. ● Model No. The inside of the projector can shatter and may cause injury. Make sure that the lamp is depending on the projector. 6 Reset the lamp counter. Put the lamp cover back and secure it with a ...the screw that secure the lamp. The glass can become very hot. Screw Handle Screws ORDER REPLACEMENT LAMP Replacement lamp can be ordered through your projector : PLC-ET30L ● Replacement Lamp Type No. : POA-LMP116 (Service Parts No. 610 335 8093) 59 The timing when the LAMP REPLACE indicator ...
... lamp with the screw. 5 Connect the AC power cord to the dealer. ● Model No. The inside of the projector can shatter and may cause injury. Make sure that the lamp is depending on the projector. 6 Reset the lamp counter. Put the lamp cover back and secure it with a ...the screw that secure the lamp. The glass can become very hot. Screw Handle Screws ORDER REPLACEMENT LAMP Replacement lamp can be ordered through your projector : PLC-ET30L ● Replacement Lamp Type No. : POA-LMP116 (Service Parts No. 610 335 8093) 59 The timing when the LAMP REPLACE indicator ...
Owner's Manual
Page 65
...the mouse setting on the nameplate means the product is a Directive conformity mark of the projector with referring to the projector's code. Check the batteries. Specify the model number and explain about the problem. Make sure that the mouse driver is invalid. Make... sure that the remote control code conforms to "indicators and Projector Condition." Appendix Capture function does not work . - The top control does...
...the mouse setting on the nameplate means the product is a Directive conformity mark of the projector with referring to the projector's code. Check the batteries. Specify the model number and explain about the problem. Make sure that the mouse driver is invalid. Make... sure that the remote control code conforms to "indicators and Projector Condition." Appendix Capture function does not work . - The top control does...
RS232C Basic
Page 21
...in process When the status is Power ON, and then POWER OFF Command ("C01" [CR]) is executed, it moves to Cooling Down status. The projector returns "10" [CR], which indicates it automatically starts Cooling Down operation. "80" [CR] Status: Standby When the status is Standby, Status Read ...ON without Countdown operation. PLC_ET30L Basic Serial Command Functional Specifications Details for Response "00" [CR] Status: Power ON Normal image is on models.) This function is intended to cool down during this process, the given Cooling Down process is conducted. 21/24 During this case Fan ...
...in process When the status is Power ON, and then POWER OFF Command ("C01" [CR]) is executed, it moves to Cooling Down status. The projector returns "10" [CR], which indicates it automatically starts Cooling Down operation. "80" [CR] Status: Standby When the status is Standby, Status Read ...ON without Countdown operation. PLC_ET30L Basic Serial Command Functional Specifications Details for Response "00" [CR] Status: Power ON Normal image is on models.) This function is intended to cool down during this process, the given Cooling Down process is conducted. 21/24 During this case Fan ...
RS232C Basic
Page 23
..."_31.5_ _35.2_ 33.4 " [CR] The first sensor's data is selected. With several built-in temperature sensors, the projector returns the values in temperature sensors, it %3 starts with 5 digit numbers. PLC_ET30L Basic Serial Command Functional Specifications 7.4 Input Mode Read...Command "CR4" [CR] Detail Get screen setting status such as Ceiling/Rear. Acceptable "%1" [CR] "1" = Input 1 is selected.(only for Networking-capable models) Unacceptable "?" [CR] 7.5 Lamp Time Read Command Command "CR3" [CR] Detail Get total lamp running hours with "E" like "-05.5" [CR]. ...
..."_31.5_ _35.2_ 33.4 " [CR] The first sensor's data is selected. With several built-in temperature sensors, the projector returns the values in temperature sensors, it %3 starts with 5 digit numbers. PLC_ET30L Basic Serial Command Functional Specifications 7.4 Input Mode Read...Command "CR4" [CR] Detail Get screen setting status such as Ceiling/Rear. Acceptable "%1" [CR] "1" = Input 1 is selected.(only for Networking-capable models) Unacceptable "?" [CR] 7.5 Lamp Time Read Command Command "CR3" [CR] Detail Get total lamp running hours with "E" like "-05.5" [CR]. ...
RS232C Expand
Page 37
...CF_POWER_%1" [CR] "ON Power ON "OFF Power OFF * Issuing another command during this operation even if this model has only "ON" / "OFF". PLC-ET30L Expand Serial Command Functional Specifications operation is not stopped before getting back a return value during countdown process forced countdown operation...command is impossible to be terminated. * Error Code is returned in the normal Power ON status) Receiving FREEZE_ON command when the projector is Freeze enabled, Freeze status is received again. Therefore, to the command CF_POWER ON. "OFF Set Freeze to OFF. ...
...CF_POWER_%1" [CR] "ON Power ON "OFF Power OFF * Issuing another command during this operation even if this model has only "ON" / "OFF". PLC-ET30L Expand Serial Command Functional Specifications operation is not stopped before getting back a return value during countdown process forced countdown operation...command is impossible to be terminated. * Error Code is returned in the normal Power ON status) Receiving FREEZE_ON command when the projector is Freeze enabled, Freeze status is received again. Therefore, to the command CF_POWER ON. "OFF Set Freeze to OFF. ...