Page 14
... an error. Example: 20H 81H 01H 60H 01H 00H 03H CKS (*4) Response error number This is the value of the lower 8 bits of the results calculated in byte units from all of operation Bit 7: Power On/Off processing Data portion of the projector. RUNNING SENSE Function: This command acquires the operation...
... an error. Example: 20H 81H 01H 60H 01H 00H 03H CKS (*4) Response error number This is the value of the lower 8 bits of the results calculated in byte units from all of operation Bit 7: Power On/Off processing Data portion of the projector. RUNNING SENSE Function: This command acquires the operation...
RS232 codes- Projectors
Page 29
... seconds C0H 65H 52H 00H : Total 5400000 seconds/3600 = 1500 hours 00H E4H 57H 00H : Total 5760000 seconds/3600 = 1600 hours Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to 10800 seconds : Starting time for acquiring remaining lamp ...in terms of Normal mode values) : Lamp Hour Meter (Normal mode) DATA01 DATA02 DATA03 DATA04 30H 2AH 00H 00H : 10800 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA04 DATA03 DATA02 DATA01 (00002A30) 3) Change from HEX to 5400000 seconds * The projector's hours of use...
... seconds C0H 65H 52H 00H : Total 5400000 seconds/3600 = 1500 hours 00H E4H 57H 00H : Total 5760000 seconds/3600 = 1600 hours Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA86 DATA85 DATA84 DATA83 (005265C0) 3) Change from HEX to 10800 seconds : Starting time for acquiring remaining lamp ...in terms of Normal mode values) : Lamp Hour Meter (Normal mode) DATA01 DATA02 DATA03 DATA04 30H 2AH 00H 00H : 10800 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA04 DATA03 DATA02 DATA01 (00002A30) 3) Change from HEX to 5400000 seconds * The projector's hours of use...
RS232 codes- Projectors
Page 30
... Reserved DATA05 lamp remaining amount (100% to Decimal - LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in Eco mode. Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00) 3) Change from HEX to -10%) Response: At the time of a failure A3H 94H 01H xxH...
... Reserved DATA05 lamp remaining amount (100% to Decimal - LAMP INFORMATION REQUEST 3 Function: This command acquires the information on the projector lamp in Eco mode. Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00) 3) Change from HEX to -10%) Response: At the time of a failure A3H 94H 01H xxH...
RS232 codes- Projectors
Page 31
... until lamp warning message starts to Decimal - value will change to 18000 seconds Lamp's use of hours 50H 46H 00H 00H: 18000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to appear = 360000/ 3600= 100 hours (!) Lamp... 03H 96H 00H 00H 02H 00H 08H A3H Example of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00057E40) 3) Change from HEX to appear (in terms of Eco mode values) ...
... until lamp warning message starts to Decimal - value will change to 18000 seconds Lamp's use of hours 50H 46H 00H 00H: 18000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00004650) 3) Change from HEX to appear = 360000/ 3600= 100 hours (!) Lamp... 03H 96H 00H 00H 02H 00H 08H A3H Example of acquisition DATA03 DATA04 DATA05 DATA06: Remaining time 40H 7EH 05H 00H: 360000 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA06 DATA05 DATA04 DATA03 (00057E40) 3) Change from HEX to appear (in terms of Eco mode values) ...
Specification Brochure
Page 1
PE Series PE401H digital projector Entry Level Installation Projector A powerhouse projector packed with essential features, the PE Series projector is designed for conference and classrooms. Essential Features for ... startup. A green ECO Mode button on non-white surfaces • Plug and Play setup and operation optimizes images displayed from a computer • Carbon savings meter calculates the positive effects of operating the projector in ECO Mode, which is detected from computers and video sources • Flexible input panel, color-coded and...
PE Series PE401H digital projector Entry Level Installation Projector A powerhouse projector packed with essential features, the PE Series projector is designed for conference and classrooms. Essential Features for ... startup. A green ECO Mode button on non-white surfaces • Plug and Play setup and operation optimizes images displayed from a computer • Carbon savings meter calculates the positive effects of operating the projector in ECO Mode, which is detected from computers and video sources • Flexible input panel, color-coded and...
Launch Press Release
Page 2
... needed for 1 year or 500 hours, whichever comes first. 2 Meanwhile, a carbon savings meter calculates the positive effects of operating the projector in May 2013 at startup. The PE401H includes the following features: • Native resolution of the inputs The PE401H projector ships with no cooling required after shutdown) ensures efficient energy usage. The...
... needed for 1 year or 500 hours, whichever comes first. 2 Meanwhile, a carbon savings meter calculates the positive effects of operating the projector in May 2013 at startup. The PE401H includes the following features: • Native resolution of the inputs The PE401H projector ships with no cooling required after shutdown) ensures efficient energy usage. The...